Home Companies Shenzhen Veikong Electric Co., Ltd.

2.2KW 4KW GPRS Pump Inverter Solar VFD For Solar Irrigation System

Shenzhen Veikong Electric Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China

Contact name:Terry

Inquir Now

Shenzhen Veikong Electric Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

2.2KW 4KW GPRS Pump Inverter Solar VFD For Solar Irrigation System

Country/Region china
City & Province shenzhen
Categories Contactors
InquireNow

Product Details

2.2KW 4KW GPRS Pump Inverter Solar VFD For Solar Irrigation System

 

2.2KW 4KW Solar Pump Inverter GPRS Solar VFD For Pump Solar Irrigation System

 

VEIKONG IS Solar Ac Pump Controller chinese manufacturer

 
Performance features:(220v 0.75kw-75kw, 380v 0.75kw-250kw)
Features:
  1.  Support Hybrid solar power and ac power at same time
  2.  Support optional LCD keypad, you will know all parameters meaning , no need user manual
  3.  Support optional GPRS module to remote control and monitor solar pumping situation
  4.  Support optional output reactor to protect the motor
  5.  Support water full, dry running, wake and sleep protection functions.

 

 

Electrical Specifications

 

PV input
Maxiumum input DC voltage400V DC
Recommended MPPT voltage range250~350V DC
Recommended input Operation Voltage310V DC
Grid or backup generator input
Input voltageSingle phase 220V(-15%~30%)
Output Specification
Rated output voltage3PH 220V
Output frequency0~500.00Hz (default: 0~50.00Hz)
380V Solar Pumping Inverter
Input Specification
PV input
Maxiumum input DC voltage800V DC
Recommended MPPT voltage range450~650V DC
Recommended input Operation voltage540V DC
Grid or backup generator input
Input voltageThree phase 380V(-15%~30%)
Output specification
Rated ouput voltage3PH 380V
Output frequency0~500.00Hz (default: 0~50.00Hz)
Protection
Built-in ProtectionLighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc.

 

 

 

Accessories:

 

1. GPRS (support 2g/3g/4g internet)

 

2. Output reactor

 

3. LCD keypad

 


 

 



 


 

 

Model Range

Drive ModelRelated VoltageMax DC input voltage (V)Rated output current (A)Applicable water pump (KW)SIZE
VFD500M-20T00150-PV220V80071.5SIZE A
VFD500M-20T00220-PV220V80010.62.2SIZE A
VFD500M-40T00150-PV380V8004.21.5SIZE A
VFD500M-40T00220-PV380V80062.2SIZE A
VFD500-20T00150-PV220V80071.5SIZE A
VFD500-20T00220-PV220V80010.62.2SIZE A
VFD500-20T00400-PV220V800174SIZE A
VFD500-40T00150-PV380V8004.21.5SIZE A
VFD500-40T00220-PV380V80062.2SIZE A
VFD500-40T00400-PV380V8009.44SIZE A
VFD500-40T00550-PV380V800135.5SIZE B
VFD500-40T00750-PV380V800177.5SIZE B
VFD500-40T01100-PV380V8002511SIZE C
VFD500-40T01500-PV380V8003215SIZE C
VFD500-40T01850-PV380V8003818.5SIZE D
VFD500-40T02200-PV380V8004622SIZE D
VFD500-40T03000-PV380V8006030SIZE E
VFD500-40T03700-PV380V8007537SIZE E
VFD500-40T04500-PV380V8009645SIZE F
VFD500-40T05500-PV380V80011255SIZE F
VFD500-40T07500-PV380V80015075SIZE G
VFD500-40T09000-PV380V80017690SIZE G
VFD500-40T11000-PV380V800210110SIZE H
VFD500-40T13200-PV380V800253132SIZE I
VFD500-40T16000-PV380V800304160SIZE I
VFD500-40T18500-PV380V800340185SIZE J
VFD500-40T20000-PV380V800377200SIZE J
 

 

 

 

Trial run(How to start solar pump inverter)
Make sure all cables connections of solar panel and pump motor correct and no
need to set any parameter, if you want to set parameter, you can do as follows.
 
Step 1: (Keypad control):Set motor parameter P11.02- P11.06 as per motor pump name
plate If dry run protection is required, measure the unload protection current(see details in
user manual chapter for dry run function) If dry run protection not required then miss this step
and go to step 2.
 
Step 2: Set other related special solar pump parameters for optimization if needed.
 
Step 3: After trial run finishing, if motor pump still not output water when inverter is running
more than 40 Hz. Please disconnect the power supply and replace any two-phase wiring of
the motor

 

Technical Questions and solutions

 
1. How to achieve Automatic start after stop?
If it is controlled by keyboard, so there is no need to set any parameter(P47.03 waiting time)If you want to
control by external switch. First set P00.06=1 and use a wire or switch to connect com and DI1,When the
switch is closed, the drive run, when the switch is open, the drive stop
 
2. How to use a float in the water tank to stop the pump if the tank is full?
If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
143.Use level probe in the well for protection against dry running
 
1 st solution: See self learning of dry run(For LED display)
 
2 nd solution: do it manually Set P24.13=30%-60%(as per real empty load current percentage based on
rated current) and P24.14 P24.16 and P23.21
 
3 rd solution: If your sensor is digital switch, just short D4 and com
 
4 th solution: If your float signal is Analog signal, Connect Ai2 and 10V and GND and set P41.00=23 and
P41.03-P41.06
 

 

Hot Products

7.5KW 11KW 15KW 18.5KW VFD Frequency Inverter 3 Phase With LCD Keyboard Product Features of Three ...
22KW 30KW 37KW 45KW VFD Variable Frequency Drive 3 Phase Vector Control 22KW 30KW 37KW 45KW VFD ...
SVC VC Torque Control VFD Frequency Inverter 3 Phase 380V 440V 480V 55KW 75KW 90KW 110KW VFD ...
VFD580 High End Frequency Inverter With DC Reactor For Injection Machine VFD580 is a high-standard ...
Special VFD High Performance frequency inverter with LCD display High performance Drive three phase ...
Special VFD high performance frequency inverter support PMSM motor High performance Drive three ...