Product Details

8sec DC24V Brushless Motor Parking Barrier Gate Arm Swing out Parking Lot Management

 

 

1. Selection of spring

 

The spring is stretchable one and

the specification is as follows:

 

Diameter 4.0MM green color

            Diameter 4.5MM red color

Diameter 5.5MM blue color

Diameter 6.8MM yellow color

       Diameter 7.0MM white color

2. Function setting description:

When setting the function, please press the menu button on the control panel. The Nixie tube displays H00-00 or H00-other numbers. We correspond to the function parameter table code to enter the required function parameter setting. For example, H00-00 is the UP ARM speed adjustment, and then press the confirm button Enter the parameter setting, the number will be displayed on the digital tube, then press the up or down key to set the required UP ARM speed number, and then press the confirm button to complete the ARM-up speed setting.

The other function settings are the same as the example settings.

3. Features

3.1 The running speed can be adjusted from 2.5s to 8s

3.2 Arm can be quickly interchanged.

3.3 Open the barrier gate by motor wheel when power off ,automatically reset after power on

3.4 Curved crank arm three- link movement structure, the operation is stable

3.5 Wireless remote control control open/close

3.6 Auto reverse function(force adjustable)

3.7 Infrared photocells connector is available

3.8 Loop detector connector is available.

3.9 Well-integrated with car parking system equipment,with wire control(must be switch signal)

3.10 Connector for traffic light(AC220V,power less than 40W)

3.11 Offering dry contact signal for car parking system(COM,NC,NO)

3.12 Auto-delay when closing(adjustable)

3.13 RS485 or CAN network communication interface(no need to install module)

3.14 Counting interface

3.15 24V backup battery interface(Can be charged by using solar energy)( optional)

3.16 Arm open when power off ( add backup battery) (Optional)

3.17 Anti-collision alarm device

4.Technical parameters

4.1 Working temperature(motor): -30℃~+70℃

4.2 Rated voltage:DC24V

4.3 Running speed:2.5s-8s

4.4 Rated current:9.5A

4.5 Rated power:150W

4.6 No-load speed:1850rpm

4.7 Rated speed:1400rpm

4.8 Rated torque:59.6N.m

4.9 Relative humidity:≥85%

4.10 Remote control distance:≤100M(in the open place)

4.11 IP Degree:IP44

4.12 Max length of arm:6M

 

 

5.The parameter for selecting the spring

 

Arm typeArm lengthUse of spring
TypeDimension(Wire Diameter*Length)
100*45 Straight arm6mTension spring4.5+5.5
5m4.0+5.5
4.5m4.5+4.5
4m4.5+4.0
3.5m4.5
3m4.5
80*45Straight arm6m5.5+4.0
5m5.5+4.0
4.5m4.5+4.5
4m4.5+4.0
3.5m4.5
3m4.0
Two fence arm4.5m5.5+5.5
4m4.5+5.5
3.5m4.5+4.5
3m4.5+4.5
90 degree arm5m5.5+4.5
4.5m5.5+4.5
4m4.5+4.5
3.5m4.5+4.5
3m4.5+4.0
Three fence arm4.5m5.5+6.8
4m5.5+5.5
3.5m4.5+5.5
3m4.5+4.5
Remark:6.8 yellow,5.5 blue,4.5 red,4.0 green
(the parameter is based on the company’s arm)

 

 

6.Function setting parameter table

 

Menu codeParameter ScaleParameter nameDefaultUnitRemark
H00-0025-95Open speed adjustment40 Corresponding PWM duty cycle 25%-95%, step size is 1
H00-0125-95Close speed adjustment40 Corresponding PWM duty cycle 25%-95%, step size is 1
H00-025-40Open in place decelerate angle35 The larger the angle value, the less likely it is to shake the arm when it is in place.
H00-035-40Close in place decelerate angle35 The larger the angle value, the less likely it is to shake the arm when it is in place.
H00-041-20Open accelerate adjustment1msThe smaller the number, the faster the speed
H00-051-20Close accelerate adjustment8msThe smaller the number, the faster the speed
H00-061-30Open in place angle1degreestep size is 1, when big than 11, will automatically check one side
H00-071-30Close in place angle1degreestep size is 1
H00-087-13Auto reverse force adjustment10Astep size is 1
H00-090-90Delay closing adjustment0secondstep size is 100;0 is not closing automatically,Other value will be closing automatically; This parameter is for the situation that there is no loop detector signals and non-automatic operation occasions
H00-1010-50Self-check speed adjustment30 Corresponding PWM duty cycle 10%-50%, step size is 1
H00-110-2Self-check mode0 0:no operate automatically;1:operate automatically, eliminate after power off;2:operate automatically,Power failure memory.3.intelligent automatically operation.
H00-120-5Self-lock force adjustment0 0:Invalid , 1or 2 valid
H00-131-20Motor deceleration time when paused5 The larger the setting, the longer the pause time will take
H00-140-1Bid-direction setting0 0:Closing,1:opening
H00-150-2Energy saving closing arm direction0 

0:invalid

1:close arm valid(energy saving voltage is determined by 49 items )

2:open arm valid

H00-161-32RS485communication address1 Up to 32 slaves can be connected
H00-170-2RS485communication rate0 0:9600,1:19200,2:38400;Change the parameter and will be valid after power on again.
H00-180-2Whether to self-check when power on1 0:no self-check,1:self-check;2:self-check with remote control;
H00-190-3self-check setting2 0:Manually invalid,1:Keyboard SET button,2:remote control valid,3,Keyboard SET button and remote control both valid
H00-200-15Monitoring parameter setting index7 00XD000Rotate speed0~2500
10XD001Motor feedback angle0~90 degree
20XD002Busbar voltage(V)0~40.0
30XD003Current output 
40XD004Hall state0~7
50XD005Commutation number 
60XD006Total number of trips 
70XD007Run time(ms)0~9000
80XD008Cumulative running times0`99999999
90xD00ATime of automation operation0~99999999
100xD00CTime of anti-Collision0~99999999
110xD00EThe number of times of the arm is close in place0~99999999
120xD010Power on time(minute)0~99999999
130xD012Power supply power on times0~99999999
140xD014Running statusBinary display
150xD015Fault code0~7
19 Number of UP arm0-65535
20 Number of DOWN arm0-65535
21 Number of STOP0-65535
22 Number of Loop detector0-65535
23 Number of Photocell0-65535
24 Number of Camera0-65535
H00-210-3Factory data reset0 1:Factory data rest,2:cumulative number of times cleared 3:Accumulate the number of times to clear and restore factory settings, return to 0 after execution
H00-220-1Start acceleration time constant0 The higher the value, the slower the acceleration
H00-2312-30Minimal output10 Minimum output duty cycle of UP/DOWN arm
H00-2412-30STOP key function setting  0:whenever you press pause, ARM stay in the current state 1:when close arm, press the STOP key to switch the arm to up command
H00-251-20Reserve   
H00-260-1Camera count timeout(seconds) S0:count cleared when10 minutes time out, Not 0 is timing close arm
H00-270-1    
H00-280-3LED light output mode  0:Do not flash alternately during operation;1:Allow flashing; 2:Green light when UP arm on 45 Degree
H00-290-2Multi function count input  

0:no counting function

1:UP counting

2:Counting input

3:directly stop when the alarm input is valid

4:when the alarm input is valid, it only prompts the alarm, and run normally

H00-300~1DO1 functional output  

0:UP in place

1:DOWN in place

2:UP&DOWN in place

3:Fault input alarm(valid when 29 item set to 1)

H00-31 DO2 functional output0-5 
H00-32 DO3 functional output  
H00-33 485 communication status control  485 communication, analog input port data
H00-34 Peak pattern0-1 Long press remote control whether to prohibit the use of IO port; 0: No prohibition effect; 1: effective
H00-35 Peak status0 1 or 2 :Peak pattern is effective,3:close loop detector function (setting it when 34 item is valid)
H00-36 Beeper setup0 0:close 1:effective
H00-37 Single stroke setting  500~1000 (In bilateral detection, see item 6 of monitoring parameters. In bilateral detection, parameters are invalid.)
H00-47 Motor type setting  

0:Gear

1:Turbine vortex rod

2:Advertising machine

H00-48 Loop detector detect time constant  The smaller the setting, the more sensitive it is to the loop detector
H00-49 Energy-saving voltage of UP&DOWN arm  18.0~23.0V; over-setting will not work properly when power off
H00-50 The delay time of closing arm when loop detector invalid  how long is the delay after turnover is in place, then close arm again

 

Wonsun is a professional manufaturer for barrier gate, boom barrier, sliding gate motor. If any interest, please contact me freely.
Email: keira@wonsunbarrier.com
Skype: zimin1314
Whatsapp: +86 185 0748 1610
Wechat: Keira_Xia

Intearking Barrier Gate 6m Arm with DC24V Brushless Motor For Parking lot SYSTEM

Hot Products

Cheap 24V DC Brushless Motor Speed Adjustale Vehicle Barrier Gate With Backup Battery Vehicle ...
WONSUN Servo Motor 24V Barrier Gate 200W DC Motor Vehicle Barrier Gate Operation Time and Boom ...
Non-spring DC Brushless Motor 24V Barrier Gate Automatic Boom Barrier Gate With 6m Arm Vehicle ...
New Design Non-spring 24V DC Brushless Motor Vehicle Barrier Gate Parking Boom Barrier Without ...
Advertising Barrier Gate 24V BLDC Brushless Motor Advertising Vehicle Barrier Gate Our Advantages: 1...
DC Motor Vehicle Barrier Gate barreras vehículo 6m Automático Description Of Vehicle Barrier Gate 1. ...