Sino-NSH Oil Purifier Manufacture Co., Ltd |
Verified Suppliers
|
|
Insulation oil purifier Oil Filtration equipment Vacuum filtration system transformer oil filtration plant
I. Description of transformer insulation oil purifier
VFD transformer oil purifier can effectively remove moisture, gas and impurities in the insulating oil, improve the pressure resistance of the oil and the quality of the oil, and ensure the safe operation of the power equipment. Mainly used in the power sector and industrial and mining enterprises to deal with unqualified transformer oil, transformer oil, switch oil and so on.
II. Insulation oil purifier machines' features
1. This machine has the characteristics of small size, high
efficiency and convenient movement, especially suitable for on-site
live working. It can also dry the moisture of the power equipment,
and can also conveniently vacuum the power equipment.
2. The infrared liquid level automatic control device, the system
pressure automatic protection device and the high-efficiency
degassing component are adopted in the structure; the operation is
convenient.
Operation notes
1. When the vacuum pump is working, it should pay attention to the
oil condition indicated by the oil mark (the oil should be on the
oil mark line). When the vacuum pump oil has more water, it should
be replaced in time.
2. During the operation, if there is more water in the cooler, it
should be released in time.
3. Always pay attention to the change of pressure gauge value. When
the pressure is >0.3Mpa, the filter should be cleaned or the
filter element replaced.
4. The filter screen of the primary filter, the secondary filter
and the fine filter should be removed and cleaned frequently to
keep it clean so as not to block the plug, resulting in
insufficient oil or excessive pressure.
5. During operation, pay attention to whether the running noise of
the pump and the corresponding motor is normal. If abnormal, it
should be eliminated immediately.
6. When the machine is not in use, the residual oil in the oil
machine should be put out.
III. Available Options of our tansformer insulation oil purifier
1. Normal appearance type,shelf-covering type and explosion-proof
type.For outside using to protect the machine escape from sunshine
and rainy.
2. Fixing type,mobile type with four wheels and mobile type with
trailer.For factory using, you can move it to everywhere you want.
3. Avaliable in different color as you required.
IV.Another models of transformer oil purifier
VF series-- Single-Stage Vacuum Insulation Oil Filtration Machine
VFD series-- Double-Stage Vacuum Transformer Oil Filtration Machine
VFD-R series-- Double-Stage Vacuum Insulation Oil Regeneration Filtration Machine
V. Technical Specification
Technical Specification | |||||||||
Item | Unit | VFD-30 | VFD-50 | VFD-80 | VFD-100 | VFD-150 | VFD-200 | VFD-300 | |
Flow Rate | L/H | 1800 | 3000 | 4800 | 6000 | 9000 | 12000 | 18000 | |
Vacuum Range | Mpa | -0.092 ~ -0.099 | |||||||
Working Pressure | Mpa | ≤0.2 | |||||||
Max Vacuum Range | Pa | ≤50 | |||||||
Temperature Range | ℃ | 45 ~ 65 | |||||||
Breakdown Voltage | Kv | ≥75 | |||||||
Impurity Size | μm | ≤5 | |||||||
Dielectric Loss | Tg | ≤0.005 | |||||||
Interfacial Tension | mn/m | ≥40 | |||||||
Water Content | PPM | ≤4 | |||||||
Gas Content | % | ≤0.1 | |||||||
Power Supply | 380V/3P/50Hz(or as needed) | ||||||||
Working Noise | dB(A) | ≤72 | ≤78 | ||||||
Heating Power | Kw | 30 | 48 | 72 | 90 | 120 | 180 | 240 | |
Total Power | Kw | 35 | 54 | 77 | 98 | 129 | 189 | 254 | |
Pipeline Diameter | mm | DN25 | DN32 | DN32 | DN40 | DN50 | DN65 | DN65 | |
Net Weight | Kg | 550 | 850 | 1000 | 1100 | 1400 | 1600 | 2200 | |
Size | length | mm | 1500 | 1500 | 1700 | 1900 | 2100 | 2100 | 2600 |
width | mm | 1200 | 1200 | 1500 | 1400 | 1550 | 1550 | 1800 | |
high | mm | 1750 | 1750 | 1850 | 1800 | 1900 | 1900 | 2000 |
VI. Another types of our oil purifier machines
TF series: Turbine oil purifier system is particularly suitable for
purifying turbine lubricating oil. It also applys to treat
hydraulic, coolant oil and other lubrication in which contain large
of water, vapor, impurities, sludge, dielectric and colloid. It can
eliminate them effectively and efficiently.
LV series: Lubrication Oil Filter System are suitable especially for
purifying and restoring hydraulic oil, machine oil, coolant oil and
various other lubrication oil.
GER series: Used oil regeneration system is suitable to regenerate used
internal-combustion engine oil including diesel engine oil,
gasoline engine oil, and used hydraulic oil, other used lubrication
oil of machinery.
GED series: it is used to recycle all kinds of waste oil into base oil or diesel oil with high quality.