Home Companies GUANGDONG KEJIAN INSTRUMENT CO.,LTD

408L -40℃~170℃ Programmable Temperature Humidity Test Chamber With TEMI880 Control System

GUANGDONG KEJIAN INSTRUMENT CO.,LTD

Contact Us

[China] country

Trade Verify

Address: Room B101,North Block,Gaosheng Technical Park,Hongtu Road,Nancheng District,Dongguan City,Guangdong Province,China

Contact name:Silivia Zhang

Inquir Now

GUANGDONG KEJIAN INSTRUMENT CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

408L -40℃~170℃ Programmable Temperature Humidity Test Chamber With TEMI880 Control System

Country/Region china
City & Province dongguan guangdong
Categories Wet Wipes
InquireNow

Product Details

408L Programmable Temperature and Humidity Test Chamber With TEMI880 Control System
  


Uses:


500L Programmable Temperature and Humidity Test Chamber With TEMI880 Control System can simulate different environment condition. It's appropriate for testing material performance, such as resist heat, resist dry,resist humidity and resist cold. That can define performance of material.
 


Character:


1.Use the high precision microcomputer touch temperature and humidity controller with high stability of platinum resistance to temperature and wind speed in the circulatory system of temperature and humidity test.
2.control temperature&humidity well-distributed, precisely and steady.
3. Completely independent system separate for testing in high temperature, low temperature and constant temperature&humidity environment.
 


Standard:

 

GB11158High Temperature Test Chamber Technical Condition
GB10589-89Low Temperature Test Chamber Technical Condition
GB10592-89High-low Temperature Test Chamber Technical Condition
GB/T10586-89Damp Heat Test Chamber Technical Condition
GB/T2423.1-2001Low Temperature Test Chamber Test Methods
GB/T2423.2-2001High Temperature Test Chamber Test Methods
GB/T2423.3-93Damp Heat Test Chamber Test Methods
GB/T2423.4-93Alternating Damp-Heat Test Methods
GB/T2423.22-2001Temperature Changing Test Methods
IEC60068-2-1.1990Low Temperature Test Chamber Test Methods 
IEC60068-2-2.1974High Temperature Test Chamber Test Methods
GJB150.3High Temperature Test Methods
GJB150.4Low Temperature Test Methods
GJB150.9Damp Heat Test Methods
 
 

Specification:

 

ModelKJ-2091
Inner size W×H×D(cm)80 x 70 x 80
Outside size W×H×D(cm)130 x 100 x 170
Inner chamber volume(V)500L
Outside size130 x 100 x 1700
Temperature and humidity Controll range-40℃~150℃ RH20%-98%
FunctionTemperature and humidty fluctuation±0.5℃;±2.5%RH
Temperature and humidity deviation±0.5℃-±2℃;±3%RH(>75%RH); ±5%RH(≤75%RH)
Controller resolution±0.3℃;±2.5%RH
Controller brandKorea TEMI880

Heating Time
(RT-HT)℃/min

100150
4050

Cooling Time
(RT-LT)℃/min

-20-40-60-70
40505580
Power supply KW4.06.06.06.0
MaterialInner materialSUS 304# steel plate
Outside materialSUS 304# steel plate(surface disposing)
Thermal insulation materialThermostability high density chlorine formic acid foam insulator material
System wind pathround-robin modecentrifugal fan-broadband enforce circulation
Refrigeration waySingle stage compression refrigeration
Refrigeratorwhole sealing piston France Taikang brand Compressor
Freezing fluidR4O4A or USA Dupont environmental protection refrigerant(R23+R404)
Condensation wayforced air cooling or water-cooling
HeaterNichrome heating wire heating
HumidifierSemi-enclosed steam humidification
Water-provide wayfull-automatic periodical feeding
Standard configuration1 Observe window(double-deck cavity toughened glass),1 50mm test hole in the left,1 PL inner chamber lamp,2clapboards, 1 bag of wet and dry bulb,3 fuses, 1 power line.
Safety deviceNon- fuse-switch〔compressor overload, refrigerant high low voltage,over-humidity and temperature protection,Protection switch,fuse stoppage warning system
Power1φ 220V AC±10% 50/60Hz 3φ 380V AC±10% 50/60Hz
 
 

RFQ:


Why choose us?
1. Considerate Service Different countries plugs, manually change the-voltage from 110V to 220V, insurance indicator.
2. Excellent after sale service:
1 YEAR warranty. If you have any problems during testing process, we promise we will give you a reply with 24 hours and solution provide within 3 working days. What you need to do is to send us the controller.
 
3. Good Packaging:
Covered with air bubble film before put the machine into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
 

 

Pictures:


Hot Products

1200×620×550mm 4.5m/min Speed Continuous Hotmelt Coating Laminating Machine Easy Install Uses: The ...
Round Roller Extrusion Hot melt Coating Machine Easy Install with size 1200×620×550mm Description ...
5KW Hot Melt Lamination Machine With Water Based Lab Coating And Comma Scraper Uses: This machine is ...
120KG Hot Melt Coating Machine With 1200 × 620 × 550mm Size 1 Phase AC 220V Uses: The precision ...
1200×620×550mm White UV Lab Coating Machine Hot Melt Adhesive 1 Phase Ac 220v 1050w Uses: Spot Hot ...
Laboratory Film Automatic Coater Small Automatic Proofing Machine Usage: In order to make it ...