Product Details

Insertion Ultrasonic Flow meter TF1100-EI Wall-mounted Type Liquid Measure
 
Insertion Ultrasonic Flow meter TF1100-EI launched by Lanry combines years experience in metering research and development, adopting state-of-the-art technology and sophisticated production. It has been proven that Insertion Ultrasonic Flow meter TF1100-EI is reliable and absolute matured achievement in high accuracy measurement.
Insertion Ultrasonic Flow meter TF1100-EI provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
 
Insertion Ultrasonic Flow meter TF1100-EI Wall-mounted Type Liquid Measure Features:
 
1. Thermal energy measurement capability can be optional.
2. Wide liquid temperature range: -35℃~200℃.
3. Data logger function for insertion ultrasonic flow meter
4. For commonly used pipe materials and diameters from 20mm to over 6.0m.
5. Hot-tapped installation, no pipe line flow interrupted

6. Wide bi-directional flow range of 0.01 m/s to 12 m/s..

 

Application
 

General

● Performance and efficiency measurement
● Service and maintenance

● Support of commissioning process and installation
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

● Energy efficiency audits

● Replacement of defective devices

 

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry

Food , beverage and pharmaceutical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

 
 

Specifications:Transmitter

 

Measurement principleUltrasonic transit-time difference correlation principle
Flow velocity range0.01 to 12 m/s, bi-directional
Resolution0.25mm/s
Repeatability0.2% of reading
Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time0.5s
Sensitivity0.003m/s
Damping of displayed value0-99s(selectable by user)
Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
Power SupplyAC: 85-265V DC: 24V/500mA
Enclosure typeWall-mounted
Degree of protectionIP66 according to EN60529
Operating temperature-20℃ to +60℃
Housing materialFiberglass
Display4 line×16 English letters LCD graphic display, backlit
UnitsUser Configured (English and Metric)
RateRate and Velocity Display
Totalizedgallons, ft³, barrels, lbs, liters, m³,kg
Thermal energyunit GJ,KWh can be optional
Communication4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
SecurityKeypad lockout, system lockout
Size244*196*144mm
Weight2.4kg

 

Specifications:Transducer

 

Degree of protectionIP67 or IP68 according to EN60529
Suited Liquid TemperatureStd. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Pipe diameter rangeDN65-6000
Transducer SizeType S Φ58*199mm
Material of transducerStainless Steel
Cable LengthStd: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 

 

Packing & Delivery

 

Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 

Delivery

Inserted Type Ultrasonic Flow Meter With 4-20mA Output 

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Hot Products

Ultrasonic flow meter clamp on flow sensor TF1100-EC by transit-time principle Ultrasonic flow meter ...
Ultrasonic transit time flow meter TF1100-EC with non contact level sensor The protection degree of ...
Insertion Ultrasonic Flow meter TF1100-EI Wall-mounted Type Liquid Measure Insertion Ultrasonic Flow ...
Insertion type ultrasonic flow meter TF1100-EI for waste water industry Insertion type ultrasonic ...
Insertion ultrasonic flow meter TF1100-EI fix installation for Chemical industry Insertion ...
Wall installed ultrasonic flow meter TF1100-EC with clamp on sensor Wall installed ultrasonic flow ...