Product Details

40KA Single Line Type 2 Surge Protection For power supply in communication station
 

Lightning protection of power supply system of communication station
 
(1) Underground power cables are used for the power lines leading into the communication equipment room, and both ends of the cable metal sheath are well grounded.
 
(2) The high-voltage side of the distribution transformer is connected to a high-voltage zinc oxide surge arrester, and the low-voltage side is connected to a power surge arrester. The transformer case and the ground of the arrester shall be connected to the grounding grid in a unified manner and shall be well grounded.
 
(3) The power supply in the communication room adopts multi-level surge protection measures. A 380V overvoltage protector is connected in parallel to the AC bus; a high-frequency switching power supply is connected to a 380V overvoltage protector in parallel; a varistor is connected to the entrance of the -48V power supply. The positive pole of the power supply of the communication equipment is connected to the grounding bus on the power supply side and the equipment side respectively.
 
(4) The power supply of communication equipment in the substation is installed in the main control room together with other substation equipment due to the lack of communication equipment. The DC power supply is taken from the 220V DC operating power supply of the substation, and transformed into -48V power supply by the DC/DC module for communication equipment. Therefore, install a first-level 380V/100G AC overvoltage protection device on the AC busbar of the electric cabinet used in the substation as a first-level lightning protection; install a first-level AC overvoltage protection device at the inlet of the high-frequency switching power supply, and The 48V output side of the DC/DC module is equipped with a primary 48V DC surge protection; finally, a 48V varistor is installed at the 48V entrance of the communication equipment.
 
(5) All AC and DC power distribution cabinets in the computer room are protected by grounding. The AC protective grounding wire is directly drawn from the grounding bus. It is strictly forbidden to use the neutral wire as the AC protective grounding wire.
 
OBV5-C40
The surge arrestors OBV5-C40-LT meet the type 2 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions. The use of high-performance varistors permits a rapid response time and a low protection level, without any line follow current. If circumstances are uncertain and there is a risk of fire from an overload, the internal cut-off unit disconnects the arrestor from the mains if necessary. In addition, the QR code printed on the arrestor allows disary. In addition, the QR code printed on the arrestor allows direct access to the online installation instructions.
Technical Parameters

Model: OBV5-C40
Maximum continuous voltage ACUcV275/320/385/440
SPD to EN 61643-11  Type 2
SPD to IEC 61643-1  class II
Nominal discharge current (8/20< s)InkA20
Maximum discharge current (8/20< s)ImaxkA40
Voltage protection levelUpkV< 1,3/1,5/1,8/2,0
Response timetAns< 25
Maximum back-up fuse A125
Temperature rangeϑ-40℃~+85℃
Protection rating  IP 20
Max. cable cross-section flexible (fine-wire) mm²25
Max. cable cross-section rigid (single wire/multi-wire) mm²35

 
Feature&Benefits
 
1,Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715.
5,It can effectively ensure the equipments work properly.
·Easy installation or retrofit.
·Din-rail mountable.
·Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact.
·IP20 finger-safe designVisual indicator.
·Small foot print.
 
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
 
Others
Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~)Response Time(ns)
DGM1(2)-D5220/380

275/320
385/420

5101.2≤25
DGM1(2)-D101021.6
DGM1(2)-C2020401.8
DGM13-B303060.2.2
DGM3(4)-B4010802.4
DGM(4)-B60601002.8
DGM-N-PE220/25540/6060/801.2≤100

 
Transient voltage surgesin lv power lines
Transient overvoltages are voltage surges that can reach tens ofkilovolts with a duration of the order of microseconds.Despite theirshort duration, the high energy content can cause serious problemsto equipment connected to the line, from premature aging to destruction, causing disruptions to service and financial loss.Thistype of surge can have various different causes, including atmospheric lightning directly striking the external protection(lightning rods) on a building or transmission line or the associatedinduction of electromagnetic fields on metallic conductors.
Outdoor and longer lines are the most exposed to these fields,which often receive high levels of induction.
It is also common for non-weather phenomena, such as transformer centre switching or the disconnection of motors orother inductive loads to cause voltage spikes in adjacent lines.
 

Surges in telecom andsignalling networks
 
Surges tend to induce currents in allmetal conductors; not only are thepower lines affected, but so are allcables to a greater or lesser extent,depending on the distance to the focusof the surge.
Although a lower current is induced,the effect produced is equally or moredestructive, due to the greatersensitivity of electronic equipmentconnected to communications lines(telephone, Ethernet, R, etc.).

 
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so limiting the peak voltage to an acceptablevalue for connected electrical equipment.
A ground connection in adequate condition is, therefore,a key aspect for effective protection against overvoltages.Monitoring ground connection condition guaranteesproper operation of surge protection devices.
 

Comprehensive protection
 
An effective overvoltage protection must combine thefollowing protection systems:
External protection (ESE lightning rods and faradization).System for protection against direct lightningstrike.These capture the lightning within the protectedarea and lead it, in a controlled manner, safely to ground. Internal protection (power frequency overvoltage andsurge protection devices). Equipment designed to protectagainst the effects of overvoltages in equipment connected to the power supply systems and/or communications networks.Grounding systems (grounding and insulation monitoring).Systems that allow atmospheric dischargecurrents to be dispersed into the ground. The need formonitoring the grounding system.CUAJE offers a widerange of products for each of these systems. It alsodevelops custom products, provides advice and consultingservices and the best possible aftersales service.
 
What skills should lightning protectors have in the selection?
 
1.Confirm power supply system

First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
 
2.Know the main parameters of the lightning arrester.
 
FAQ

 
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
 
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
 
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
 
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.

Hot Products

Voltage dependant resistor - MOV(metal oxide varistor)- 14D471K Quick Detail: • Wide voltage range ...
SMD Varistor Surface Mount Varistors SMT Metal Oxide Varistor MOV SMD MOVS voltage dependent ...
3225 SMD varistor Original 3225K201 21S Metal Oxide Varistor MOV ZOV Feature 1.Advancedpackagingtech...
UL DC 26V Factory Sale All Series SMD Varistor MOV Chip Varistor Variable Resistor AC175V - 320V ...
SMD Varistor Surface Mount Varistors SMT Metal Oxide Varistor MOV SMD MOVS voltage dependent ...
Metal Oxide Varistors OEM Adapter Use 0402 SMD Varistor Bulk Quick Detail: 1)Leadless,size 1005[0402...