Ship Refrigeration Use Shell and Tube Heat Exchanger

 

Water Cooled Evaporator

 

Shell and tube chiller evaporator is a two-layer metal plate with high-pressure gas expansion molding or

 

mechanical pressure nine way to make, can also be made of aluminum alloy die-casting. This is widely

 

used in refrigerators, merchandise showcases, popsicles storage boxes and other small refrigeration

 

equipment. Aluminum alloy die-casting made of flat shell and tube Yanfa is widely used in contact with the

 

freeze, commonly known as flat shell and tube quickzer.

 

The heat transfer coefficient of the shell-and-tube chiller evaporator is larger in the liquid than in the gas,

 

in the flow state than in the stationary state.

 

Shell and tube chiller evaporator due to better heat transfer, compact structure, small footprint, easy

 

installation, so the application is very extensive. The structure of the shell and tube chiller evaporator is

 

the same as that of the horizontal shell and tube condenser. In order to control the proper flow rate, the

 

refrigerant enters from the lower part of the end cap, flows out from the upper part and flows back and

 

forth within the duct and the end cap, and becomes a multi-way flow. And the refrigerant flows outside the

 

tube, and the refrigerant liquid after the throttling enters from the bottom or the side of the evaporator,

 

and the gas after the fire is discharged from the upper part.

 

 

FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL (SINGLE CIRCUIT)

 

CAPACITY: 700KW TO 1800KW

 

Models  QX-700MQX-820MQX-950MQX-1100MQX-1300QX-1500QX-1800
Refrigerant R22 (or other environmental refrigerants) Refrigerating capacity (KW)7008209501100130015001800
Heating capacity (KW)81095011201350162518752250
Wam3/h121141.5164190224258.5310
Wbm3/h151177205237280323387
Dpnbar0.630.650.680.720.760.790.86

 

ModelsQX-700MQX-820MQX-950MQX-1100MQX-1300MQX-1500MQX-1800M
Dimension(mm)A2710271027102710271028503050
A1500500550550550550550
A2400400450450450450450
L12860286028602860286030003200
B1420142015801580167016701670
B1740740820820860860860
C192092010031003105310531053
C292092010031003105310531053
D1480480566566616616616
D2530530616616666666666
H1350350420420420420420
H2280280380380420420420

Inlet/Outlet (diameter)

Connection

a/b(DN)200200250250250250250
c1-2 (mm)42424242545454
d1(mm)92105105105105105105
d2(mm)80808092929292
Corresponding external oilVolume (L)85100110160200240300
WeightP (KG)1360158017901930227024802660

Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water

Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C

Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C.

 

CONDENSER SERIES DOUBLE CIRCUIT

 

CAPACITY: 10RT TO 40RT

 

ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
DT1TACC2E
QXC10D6103.7816848310657518523392787.8
QXC15D6155.67168635136975185233928511.6
QXC20D6207.56168819173790185233929615.8
QXC25D6259.4521981917559023828511313219.5
QXC30D63011.3421981917559023828511313723
QXC35D63513.2321981917559023828511314527.3
QXC40D64015.1221995320249023828511316231

 

ModelS (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)
FPT(inner pipe thread)FPT(inner pipe thread)
QXC10D61/45/85/81-1/2
QXC15D61/47/85/81-1/2
QXC20D61/47/85/81-1/2
QXC25D61/41-1/87/82
QXC30D61/41-1/87/82-1/2
QXC35D61/41-3/87/82-1/2
QXC40D61/41-3/87/82-1/2

 

CONDENSER SERIES SINGLE CIRCUIT

 

CAPACITY: 220RT TO 426RT

 

ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
DT1TACEH1H2
QXC220S16A22078.5542628603326150530260310310730165.8
QXC240S16A24081.6542628603326150530260310310763181
QXC260S20A26084.3648032003666150530280310310802195.5
QXC280S20A28088.2448032003666150530280400290841211
QXC320S20A32095.2148032003666150600280400290912240.6
QXC340S22A34098.6853035003966150600300400290963256
QXC380S22A380106.53530350039661506503004002901015285.5
QXC426S22A426115.62530380042661506503004002901088320

 

ModelS (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)W (optional port)
FPT(inner pipe thread)Male flangeMale flange
QXC220S16A3/83-1/81-5/8DN125DN125
QXC240S16A3/83-1/81-5/8DN125DN125
QXC260S20A3/83-1/81-5/8DN125DN125
QXC280S20A3/84-1/82-1/8DN150DN150
QXC320S20A3/84-1/82-1/8DN150DN150
QXC340S22A3/84-1/82-1/8DN150DN200
QXC380S22A3/84-1/82-5/8DN200DN250
QXC426S22A3/84-1/82-5/8DN200DN250

 

 

COOPERATED CLENTS

Hot Products

Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...