Corrosion Resistant Tube Heat Exchanger Evaporator

 

Water - Cooled Heat Exchanger

 

Product advantages:

 

1. Internal tube: industrial 316L stainless steel tube, direct use in the strong acid bubble;

 

2. Shell: industrial corrosion-resistant chemical pipeline, white PP plastic;

 

3. Temperature can be -20 ℃ to 65 ℃ normal work;

 

4. open open maintenance, easy to clean;

 

5. Can be customized.
 
For heat exchange tube, copper pipe, copper nickel alloy tube, aluminum brass tube, stainless steel tube,

 

etc.
 
The shell raw material mainly are seamless steel tube, stainless steel pipe.

 
1, Heat exchange tube: four main tube type.
 
(1) ∅ within 3/8 "thread copper coil, it is mainly used for" U "type tube evaporator.
 
(2) ∅ within 1/2 "threaded straight copper tube, straight tube is mainly used for dry-type evaporator.
 
(3) ∅ 1/2 "corrugated straight stainless steel tube, straight tube is mainly used in food industry of dry evaporator.
 
(4) ∅ 5/8 "inside outside screw wing efficient copper tube, it is mainly used for air precooling industry dry evaporator.
 
2, shell raw material:
 
There are two of the major materials:
 
(1) # 20 seamless steel tube, mainly used for all kinds of load - more than 20 ℃ cold agent.
 
(2) 304/316 l stainless steel tube, it is mainly used for food and low temperature (below 25 ℃, higher than

 

40 ℃) of the refrigerant, 316 l can also be used for cooling load of the sulfate for industry.
 
3, interface: 

CORROSION RESISTANT TUBE HEAT EXCHANGER EVAPORATOR

 

(DOUBLE MACHINE) CAPACITY: 320KW TO 680KW

 

Models  RE320D10RE360D12RE420D12RE470D12RE540D14RE620D14RE680D14

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW320360420470540620680
Kcal/h(×103 )267317361404464533585
Wnm3 /h53.36272.280.893107116
Wmm3 /h687081.7100105140145
Dpnbar0.430.430.350.460.410.470.49

 

ModelsRE320D10RE360D12RE420D12RE470D12RE540D14RE620D14RE680D14
Dimension(mm)A140140150150150170170
B273273325325355377377
C2500169024001500269026902860
D360360406406440460460
E370370380380400400400
F2586258624882586277627762946
VentS11/21/21/21/21/21/21/2
OutletS21/21/21/21/21/21/21/2
ConnectionW(DN)100100125125125150150
D1(mm)35354242424242
D2(mm)67678080909090
P(kg)296380398442459654669

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

CORROSION RESISTANT TUBE HEAT EXCHANGER EVAPORATOR

 

(DOUBLE MACHINE) CAPACITY: 2400KW TO 4000KW

 

Models  QX-2400MQX-2650MQX-2900MQX-3200MQX-3500MQX-3750MQX-4000M
Refrigerant R22 (or other environmental refrigerants) Refrigerating capacity (KW)2400265029003200350037504000
Heating capacity (KW)3000340037503850400043504500
Wam3/h413456.5499.6550.6602.3646688.5
Wbm3/h516571624670700750773
Dpnbar0.850.870.870.760.790.820.84

 

ModelsQX-2400MQX-2650MQX-2900MQX-3200MQX-3500MQX-3750MQX-4000M
Dimension(mm)A4845484548454845503550355035
A1550550550550550550600
A2450450450450450450500
L12500250025002500269026902690
B1570157016701670167016701670
B1805805855855855855905
C11058105811081108110811081158
C21058105811081108110811081158
D1566566616616616616666
D2616616666666666666766
H1420420420420500500550
H2420420420420500500550

Inlet/Outlet (diameter)

Connection

a/b(DN)250250250250250250300
c1-4 (mm)54545454545454
d1-2(mm)105105105105105105105
D3-4(mm)80929292929292
Corresponding external oilVolume (L)200*2210*2220*2240*2250*2270*2300*2
WeightP (KG)3820425546105080555060706900

Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water

Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C

Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C.

 

COMPANY PRODUCT IMAGES

 


COOPERATED CLENTS
 

Hot Products

Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...