TRW Medical Instrument Co.,Ltd |
Verified Suppliers
|
|
Medical ligation titanium Ligating Clip Cartridge Open and Endoscopic with CE
Specification:
Medical ligation titanium clips for use with open and endoscopic | ||||||
1 | Product code | Work with | Color | Size | Clips | EA/BX |
2 | TU401-01 | LT100 | Blue | Smal | 6 | 20 |
3 | TU401-02 | LT200 | White | Medium | 6 | 20 |
4 | TT401-03 | LT300 | Green | Medium large | 6 | 20 |
5 | TU401-04 | LT400 | Yellow | Large | 6 | 20 |
1. Using inert polymer materials
Has good biocompatibility and stabilityDoes not affect X-ray, CT,
MRI and otherimaging examinations
2. Safety lock, curved, elastic and non-slip design
Intraoperative ligation is fast, safe and reliable
3. Three model specifications
Can meet various intraoperative ligation requirementsThe lock
release device can correct the ligation position duringthe
operation
Specification
The product is intended to be used in ligating vessel /tissue
bundle for open or laparoscopic surgery
General Surgery:
Gastrectomv/Cholecystectomv/Splenectomv/ColoproctectomvAppendectomy/Hepatectomy/Gastrojejunostomy/Fundoplication
etc
Obstetrics and Gynecology:
Salpingectomy/0ophorectomy/Hysterectomy/Pelvic
Lymphadenectomy/Chocolate Cyst Excision etc.
Urinary Surgery:
Nephrectomy/Adrenalectomy/Cyst Ablation/Radical Cystectomy/Radical
Prostatectomy etc
Note:
Careful handling
For example, a choledochal duct with elasticity can still be pulled
when clamped shut, and with more space in the deltoid area, it's
still sloppy to clamp in the wrong direction and cut it longer and
shorter.
Picture I
Mistake: The curved sides of the clamp are all in the same
direction.
In hepatic cancer resection and segmental hepatectomy, due to the
poor elasticity of cirrhotic blood vessels and the narrow space
between the tumor and the liver tissue, misuse may tear the blood
vessels, or even cause hemorrhage after hooking or clamping off
half of the ducts due to failure to clearly observe the head of the
clamps, the correct use of the forceps and clamps is especially
critical.
Operation Illustration:
The direction of the clip latch (A→B) should always be toward the
operator, making it easy for the operator to see if any foreign
material or excess tissue is hooked or entrapped when the clip is
locked. This is why the clamps are designed in such a directional
arc.
In turn, the notches C (C1, C2) of the clamp are oriented toward
the ductal tissue that needs to be clipped or handled or prepped.
The design of the curved notches of the forceps is consistent with
the principles of surgical instrumentation. This requires the nurse
to choose between positive and negative orientations for
installation when securing the clamp to the head end of the
forceps, depending on the situation.
Safety:
Locking device makes clamping safer;
Anti-slip and anti-collapse design;
Can maintain the activity of the ligated stump;
Non-absorbable material, antibacterial, non-toxic, non-rejection by
human tissue.
Reliable:
Tactile sensing closing method, feeling safe;
Clamping is more complete;
No development or artifacts for X-ray, MRI and CT examinations;
No tissue reactivity, no tissue adhesion and eschar;
Hinges + bow-shaped nail legs to expand the ligation and stretch
range.
Fast:
Effectively grasp the ligation target and reduce the separation
of the ligated tissue area;
Design that does not allow the nail to fall out, saves operation
time, and can replace traditional silk ligation;
The reverse buckle device penetrates the surrounding tissue and
saves operation time.
Note:
Hem-O-Lok ligation staples are supplied sterile. Do not disinfect
the ligation nail repeatedly. The Hem-O-Lok ligation cartridge
contains barium and is radiopaque. Ligation forceps care, cleaning
and disinfection:
The biting surfaces of manual ligation forceps are very delicate
and easily damaged. Incorrect handling of the ligating forceps will
result in incorrect insertion and/or closure of the ligating
staples. Proper care, cleaning and repair are very important to
ensure proper function. Please inspect this ligation forceps before
every surgery to prevent potential damage. Pay special attention to
the clamps. Damaged or misoriented jaws may not allow the nail to
achieve acceptable closure of the occlusion.
Hem-O-Lok Large Ligature Forceps are supplied non-sterile. The
ligation forceps should be cleaned, lubricated and disinfected
before each use. Keep this booklet in a safe place.