Home Companies HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD

Lightweight Three Phase Protection Relay Test Set With 8inch LCD Screen

HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
Active Member

Contact Us

[China] country

Address: 806, No.24 Nanlian Road, Nanlian Community, Longgang Street, Longgang District, Shenzhen City, 518116 China

Contact name:William Wang

Inquir Now

HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD

Lightweight Three Phase Protection Relay Test Set With 8inch LCD Screen

Country/Region china
City & Province shenzhen
InquireNow

Product Details

Comprehensive Three-phase Protection Relay Test Set

 

Model: RELAYSTAR-806

The RELAYSTAR-806 is comprehensive three-phase protection relay test set and commissioning tool. It has 7 channels for output((3I + 4U), and every output channel is independent and simultaneous control of magnitude, phase angle and frequency values.

The RELAYSTAR-806 kit can be independently operated via embedded industrial PC with 8-inch LCD screen, full keyboard and mouse, no PC required. The operator also can connect RELAYSTAR-806 kit to laptop, use RELAYSTAR software running on the laptop with Windows operating system to fully control the RELAYSTAR-806 kit to complete all tests and save the test results into laptop.

 

Main Features

1) Universal relay test applications

2) 7-channel outputs(3I + 4U)

2) Embedded industrial PC with 8-inch LCD screen, full keyboard and mouse

3) Control and operate with or without PC

4) Independent AUX DC output

5) End to end test with in-built GPS

6) Full functional RELAYSTAR test software

7) RIO file import & export facility

8) Power system model for dynamic testing

9) Online vector display

10) Switch on to fault test(SOTF)

11) Automatic test report creation

12) Software upgrade free of charge

 

Technical Data

Current Generator

Setting range3-phase AC(L-N)3x0…40A
1-phase AC(LL-LN)1x0…120A
DC(L-N)3x…±10A

 

Power

 

3-phase AC(L-N)3x300VA at 40A
1-phase AC(LL-LN)1x1000VA at 120A
DC(L-N)3x120VA at 10A
AccuracyAC: ±1mA(≤0.2A), ≤0.1% (0.2~40A)
DC: ±5mA(0~0.5A), ≤0.2% (0.5~10A)
Resolution1mA

 

Voltage Generator

Setting range4-phase AC(L-N)4x0…150V
1-phase AC(L-L)1x0…300V
DC(L-N)3x…±160V
Power4-phase AC(L-N)4x70VA at 150V
1-phase AC(L-L)1x140VA at 300V
DC(L-N)3x80VA at 160V
AccuracyAC: ±2mV(0.2~2V), ≤0.1% (2~150V)
DC: ±10mV (0~5V), ≤0.2% (5~160V)
Resolution1mV

 

Auxiliary DC Output

Voltage range110V/220V(max.1.5A)
Powermax.165VA/330VA

 

Binary Inputs

Number8
Input characteristicsidle contact or potential-free contact
Threshold characteristics“0”:0~6V; “1”:12V~250V
Max. measuring time999999.999s
Time accuracy±1ms
Time resolution1ms

 

Binary Outputs

Number4
Typeidle contact
Break capacity250VAC/0.5A, 250VDC/0.2A

 

General Generators

Frequencyrange: 0~1200Hz
accuracy:<1mHz(0~65Hz),<10mHz(65~450Hz),<20mHz(450~1200Hz)
resolution: 0.001Hz
Phaserange: -360° ~+360°
accuracy: 0.1°
resolution: 0.01°
Harmonicsuperposition order: 2~24 times
distortion: ≤0.5%

 

Power Supply

Nominal input voltagecustomized (AC 220V/230V/120V±10%, 1-phase)
Nominal frequency50/60 Hz
Rated current10A at 230V / 12A at 115V
Connectionstandard AC socket (IEC 60320)

 

Miscellaneous

Weight18kg(39.68 lb)
Dimensions (W x H x D, without handle)405×300×164mm(15.94x11.81x6.46 in)
Connection port2 USB2.0 ports, 1 Ethernet port

 

The Comprehensive Three-phase Protection Relay Test Set RELAYSTAR-806 is primarily designed for secondary testing of protection relays. Virtually all types protection relays defined by ANSI/IEEE can be tested. The examples of what RELAYSTAR-806 can test are shown as below table.

ANSI / IEEE No.Device or Function Name
2Time Delay Staring
3Checking or Interlocking Relay
7Rate-of-change Relay
13Synchronous-speed Device
15Speed or Frequency, Matching Device
16Data Communication Device
18Accelerating or Decelerating Device
21Distance Relay
24Volts per Hertz Relay
25Synchronizing or Synchronism-check Device
27Undervoltage Relay
30Annunciator Relay
32Directional Power Relay
36Polarity or Polarizing Voltage Device
37Undercurrent or Underpower Relay
40Field Relay
44Unit Sequence Starting Relay
46Reverse-phase or Phase-balance Current Relay
47Phase-sequence Voltage Relay
48Incomplete Sequence Relay
50Instantaneous Overcurrent or Rate of Rise Relay
51AC Time Overcurrent Relay
55Power Factor Relay
59Overvoltage Relay
60Voltage or Current Balance Relay
62Time-delay Stopping or Opening Relay
66Notching or Jogging Device
67AC Directional Overcurrent Relay
68Out-of-step or Blocking Relay
69Permissive Control Device
74Alarm Relay
76DC Current Relay
77Telemetering Device
78Phase-angle Measuring Relay
79AC Reclosing Relay
81Frequency Relay
82DC Load-measuring Reclosing Relay
83Automatic Selective Control or Transfer Relay
85Carrier or Pilot-wire Receiver Relay
86Lockout Relay
87Differential Protective Relay
91Voltage Directional Relay
92Voltage and Power Directional Relay
94Tripping or Trip-free Relay

 

 

Hot Products

Economical 3-phase Protection Relay Test Set Model: HME-702 The HME-702 is classic 3-phase ...
Multifunctional Six-Phase Protection Relay Test Set Model: RELAYSTAR-1600 The Six-Phase Protection ...
High Accuracy Six-phase Protection Relay Test Set Model: RELAYSTAR-H60 High Accuracy Six-phase ...
Basic Three-phase Protection Relay Test Set Model: HME-702 The HME-702 is a basic and economical ...
Comprehensive Three-phase Protection Relay Test Set Model: RELAYSTAR-806 The RELAYSTAR-806 is ...
Multipurpose Protection Relay Test Set Model: RELAYSTAR-7000 The RELAYSTAR-7000 is a multipurpose ...