Home Companies Wuhan Rising Electric Co., Ltd.

RSJY-80 Transformer Oil Testing Equipment , Transformer Oil Dielectric Strength Tester

Wuhan Rising Electric Co., Ltd.
Active Member

Contact Us

[China] country

Address: 1st Floor, Block B, Innovation Park, Changzui Science and Technology Park, Sixth High-tech Road, Jiangxia District, Wuhan City, Hubei Province

Contact name:Jason

Inquir Now

Wuhan Rising Electric Co., Ltd.

RSJY-80 Transformer Oil Testing Equipment , Transformer Oil Dielectric Strength Tester

Country/Region china
City & Province wuhan hubei
InquireNow

Product Details

RSJY-80 Transformer Oil Testing Equipment Transformer

Oil Dielectric Strength Tester BDV Tester

Notes 

The dielectric strength tester for insulating oil is developed according to the national standard GB-86 <insulating oil dielectric strength measurement method>. The instrument is preset by a dial switch, and the program is executed strictly according to the preset parameters by a computer. After operation, the results can be printed as required. The instrument has strong anti-interference, simple operation and sound light prompt.

Test unfiltered processed oil medium

The recovered unfiltered oil medium is called inferior oil. It contains quite a lot of moisture and impurities for worse quality, and its dielectric strength is mostly below 12000V. Especially for the inferior oil with more moisture. Some of users also test it with the instrument measuring the high insulation strength in order to know the degree of its deterioration. As a result, the high-voltage test system of this instrument is damaged.

Normally, the gap between the two strings of balls of the high voltage electrode is filled with insulating oil. During the test, the voltage difference between the two electrodes increases with the step-by-step of the external pressure electrode. The oil dielectric with different insulation strength can bear the high-voltage electric field of different values. This rising high-voltage electric field causes the insulation oil dielectric to be suddenly broken down when it can't bear it. The transient large current during the breakdown is collected by the instrument and immediately cut off the switch and lose the high voltage, and then transferred to the step-down operation.

When testing the inferior oil with heavy water content, the voltage between the electrodes of the two hemispheres increases continuously. At the same time, the water particles in the oil medium are absorbed into the ball gap under the action of high-voltage electric field to form a light white mist water column, which becomes thicker and thinner, and the water resistance becomes smaller and smaller. This kind of slow change process that the water resistance becomes small and the high-voltage transformer increases (without breakdown and sudden discharge) causes the instrument to be damaged, the current limiting resistance, the fuse tube to burn out, etc.

Technical Parameters
Input voltageAC 220V
Output voltageAC 0~80kV
Rate of voltage rise2kV/s±10%
Measurement accuracy2.0 class
Time1-9/time
Mix time0~99 sec
Standing time:0~9 min 59 sec
Environmental temperature5-40℃
Relative humidity≤90%RH
Volume420mm*325mm*300mm
Weight28kg

Hot Products

RSBC-D Transformer Testing Equipment Range 0.9~10000 Automatic Variable Ratio Grouping Tester ...
RSBC-D Transformer Testing Equipment Automatic Variable Ratio Grouping Tester for Testing the Z Type ...
RSZR-01 Transformer Testing Equipment Direct-circuit HV Winding Resistance and LV Winding Resistance ...
RSZR-01 Transformer Testing Equipment Resolution 0.1μΩ Direct-Circuit Rapid Resistance Tester ...
RSZR-01 Transformer Testing Equipment 10A Transformer DC Winding Tester Three Phase Digital ...
ZSR20E Transformer Testing Equipment Double-Channel Temperature Rise DC Resistance Tester Product ...