Home Companies Dongguan Ampfort Electronics Co., Ltd.

Micro Box Radial Sub Miniature Fuse 20A 350V Leaded Time Lag

Dongguan Ampfort Electronics Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.1, Yixiang ,Liwu Industrial Park,Liwuyuan Village,Xihu District, Shilong Town,Dongguan 523325,Guangdong ,China

Contact name:James Lai

Inquir Now

Dongguan Ampfort Electronics Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Micro Box Radial Sub Miniature Fuse 20A 350V Leaded Time Lag

Country/Region china
City & Province dongguan guangdong
Categories Video Game Player Chargers
InquireNow

Product Details

 

Micro Box Type Radial Leaded Time Lag Subminiature Fuse TMS T20A 350V With UL TUV Certifications

 

Description Of The Time Lag Subminiature Fuse

 

Subminiature, radial lead, High I2 t, time-lag design, rated 350VAC, 72 DC, up to 20A, Approved by UL,CUL,TUV and complied with UL 248-Standards:In accordance with IEC60127-1, IEC60127-3 Standard sheet4, GB9364.1-1997, GB9364.3-1997.

 

 

Certification Of The Time Lag Subminiature Fuse

 

Agency

Ampere Range

Agency File Number

c UL us50mA ~ 20AE340427 (JDYX )(JDYX7)
TUV50mA ~ 20AJ50466477
c UR us50mA ~ 6.3AE340427(JDYX8) (JDYX2)

 

 

Features Of The Time Lag Subminiature Fuse

 

- High I2 t, High amp ratings to 20A

- Time lag (350 VAC)

- Meet UL 248-14

- Wide operating temperature range

- Bulk and Tape & Ammo packing available

- Full compliance with EU Directive 2011/65/EU and amending directive 2015/863

- Halogen Free and Lead Free

- UL,CUL,TUV

 

 

Application Of The Time Lag Subminiature Fuse

 

Provide individual protection for components or internal circuits.

- Power supplies

- Battery chargers

- Consumer Electronics

- Adapter

- Industrial Controllers

 

 

Part Numbering Of The Time Lag Subminiature Fuse

 

Breaking Capacity: 35A or 10In whichever is greater.
After the test, the insulation resistance value is greater than 0.1ΜΩ

 

Part No.

Ampere

Rating

Voltage

Rating

Max Voltage

Drop (mv)

I2TMelting

Integral(A2.S)

TMS0050A50mA350V16000.015
TMS0063A63mA350V16000.016
TMS0080A80mA350V15000.017
TMS0100A100mA350V15000.02
TMS0125A125mA350V7600.10
TMS0160A160mA350V5000.15
TMS0200A200mA350V2600.21
TMS0250A250mA350V2400.48
TMS0315A315mA350V2200.78
TMS0400A400mA350V2001.22
TMS0500A500mA350V1902.11
TMS0630A630mA350V1802.88
TMS0800A800mA350V1603.92
TMS1100A1A350V1405.77
TMS1125A1.25A350V1308.34
TMS1160A1.6A350V12013.60
TMS1200A2A350V10026
TMS1250A2.5A350V10042
TMS1300A3A350V10045
TMS1315A3.15A350V10090
TMS1350A3.5A350V100100
TMS1400A4A350V100120
TMS1500A5A350V100170
TMS1630A6.3A350V100290
TMS1800A8A350V100320
TMS2100A10A350V95450
TMS2120A12A350V95460
TMS2150A15A350V85480
TMS2160A16A350V85515
TMS2200A20A350V85960

 

 

Operating Characteristics Of The Time Lag Subminiature Fuse

 

% of Ampere Rating(In)

Blowing Time

150%* In60 min Minimum
210%* In2 min Max
275%* In400 ms~10 s
400%* In150 ms~3 s
1000%* In20 ms~150 ms

 

 

Selection Table Of The Time Lag Subminiature Fuse

 

 

 

 

 

Can fast-acting fuse replaced by slow blow fuse ?

 

The two can replace each other in some circuits with less stringent requirements, but cannot replace each other in circuits with strict requirements.
T2A is a slow blow fuse and F2A is a fast blow fuse. The main difference between a slow-blow fuse and a fast-blow fuse is its ability to withstand instantaneous pulse current, which means that it can resist the impact of surge current when switching on and off without moving, thus ensuring the normal operation of the equipment, so slow-blow fuses Often referred to as a surge fuse.
From a technical point of view, slow-blow fuses have a larger melting heat value and require a larger amount of energy to fuse. Therefore, for fuses with the same rated current, slow-blow fuses are much more resistant to pulses than fast-blow fuses.
Since the thermal energy value of the slow-blow fuse is larger than that of the fast-blow fuse of the same specification, the fusing time will be slower than that of the fast-blow fuse when an overcurrent occurs in the circuit.
Once the circuit fails, the overcurrent will not disappear by itself. The energy of the continuous overcurrent will greatly exceed the thermal energy value of the fuse. No matter what kind of fuse will be blown, the time difference between slow blowing and fast blowing is important for its protection requirements. It is not very important, only when there are sensitive devices in the protected circuit that need to be protected, slow fuse will have an impact on the protection performance.

Because of these differences, slow-blow fuses and fast-blow fuses are used in different circuits: pure resistive circuits (no or little surge) or circuits that need to protect sensitive and valuable components such as ICs must use fast-blow fuses; For capacitive or inductive circuits (there is a surge when switching on and off), it is best to use slow-blow fuses in the input/output parts of the power supply; in addition to protecting IC circuits, slow-blow fuses can be used in most situations where fast-blow fuses are used. It improves the anti-interference ability; on the contrary, if the fast-blow fuse is used in the place where the slow-blow fuse is used, it will often cause the phenomenon that the instant-blow fuse cannot work normally.

Hot Products

35mm Radial Disc Thermistor NTC 15A 32A 28A 25A 23A 22A 21A 20A 19A 18A 17A 16A 14A 13A 11A 10A For ...
Thin Film 10K Ohm NTC Thermistors 3270 3435 3450 3470 3950 3970 3975 4100 4200 1% 2% 5% 20mm R25(Ω)...
Power NTC Thermistor MF71-5D-30MSH MF72 5D-30 MF11 MF12 MF52 MF51 MF57 MF58 MF59 MFB Inrush Current ...
SCK-472 Analogue NTC Thermistor MF72 47D-13 47 ohm 2A 20% Negative Temperature Coefficient 47D13 ...
SCK10103LIY501 Equivalent Disc NTC Thermistor MF72 10D-11 10 Ohm 3A 2800K For 48V Electric Vehicle ...
Product Description: Features: Product Name: Power NTC Thermistor Zero power resistance @ 25°C: 5, ...