Home Companies Guangdong ALI Testing Equipment Co,.Ltd

Dustproof Temperature Thermal Cycle Test Chamber 220V Multifunctional

Guangdong ALI Testing Equipment Co,.Ltd
Active Member

Contact Us

[China] country

Address: Room 401, Building 3, No. 10, Longxi Road, Nancheng Street, Dongguan, Guangdong

Contact name:Kris

Inquir Now

Guangdong ALI Testing Equipment Co,.Ltd

Dustproof Temperature Thermal Cycle Test Chamber 220V Multifunctional

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

Long Defrosting Cycles Thermal Shock Test Chamber With 2 Zones​
 

The thermal shock test hamber suitable for examining the ability of the whole machine, components, parts and other components to withstand sharp changes in temperature. The temperature impact test can understand the impact of the test sample once or repeatedly due to temperature changes. The main parameters affecting the temperature change test are the high and low temperature values in the range of temperature change, the holding time of the sample at high and low temperature, and the number of cycles of the test, etc.

 

Product Features 

 

1. The product is beautiful in appearance, reasonable in structure, advanced in technology and exquisite in material selection, with simple and convenient operation performance and reliable equipment performance. The equipment is divided into three parts: high temperature box, low temperature box and test box. It adopts a unique thermal insulation structure and heat storage and cold storage effect. During the test, the object to be tested is completely still, and the cold and hot air are switched to the test area. To achieve the purpose of thermal shock test.


2. The most advanced measuring device is adopted, and the controller adopts a large-scale color LCD human-machine touch interactive LCD human-machine interface controller, which is easy to operate, easy to learn, stable and reliable, and displays the complete system operating status, execution in Chinese and English. and set the program curve.


3. With 96 test specifications independently set, the impact time is 999 hours and 59 minutes, and the cycle period can be set from 1 to 999 times. Time to start and stop work automatically;


4. There is a test hole with a diameter of 50mm on the left side of the box, which can be used for external power load wiring test components.

 

Temperature rangeA.high-temperature : +60 degree to +150 degree
B.low-temperature : -10 degree to -40 degree
Control temperature±2 degree
resolution0.01 degree
Heating time at high-temperature regionFrom RT to 150 about 35min (RT is from 5 degree to 30 degree).
Cooling time at low-temperature regionFrom RT to -40 degree about 50min (RT is from 5 degree to 30 degree)
Moving time and temperature recover timeA. testing bastet moving from high-temperature to low-temperature spend 10sec
B.after exchanging the temperature,the tempreature recovery time: 3min to 5min (Stabilization time ≥ 30min)
Device noiseBelow 75dB.
Weight10Kg
Testing region(hot and cold)50cm(W)*50cm(H)*50cm(D)
Outside size140cm(W)*180cm(H)*142cm(D)
Testing basket size30cm(W)*40cm(H)*30cm(D)
Inside materialSUS#304 Cold-Heat-resistant stainless steel
Outside materialSUS#304 Cold-Heat-resistant stainless steel
Insolution materialHigh-density glass wool and high strength PU foam insulation
Anti-sweat structureinsulation layer and door micro-thermal anti-sweat
ExpansionHeat reach 300 degree, cold reach -100 degree




 

Service:


1. Device installation;


2. Equipment Operation Test Technology training;


3. Equipment Calibration;


4. Daily maintenance and maintenance of equipment


5 Free technical training for visiting factories


6 24-hour Online contact


7 Free software upgrades

Requently Asked Questions:


When the temperature and humidity controller of the high and low temperature impact test chamber shows abnormal temperature (overtemperature alarm), the fault and solutions:


1. Check whether the over-temperature protector (black knob with temperature value engraved on it) is set at 150℃.


2. Check whether the circulating motor in the test box is damaged or not running.


3. Check whether the solid-state relay in the temperature part is burnt out and short-circuited.
Solution:


1. Turn the over-temperature protector to the position of 150℃, or add 30℃ to the use temperature.


2. Inform the manufacturer's customer service department to replace the circulating motor.


3. Replace the solid state relay of the temperature part (the solid state relay marked with the wire number T)

 

 

Hot Products

Touching Screen Environmental Chambers Temperature Overshoot ≤±2℃ Test Chamber Applications: 1. To ...
Touching Screen Environmental Chambers Stainless Steel SUS 304# Box structure: The water replenishme...
Touching Screen Environment Test Chambers Stainless Steel SUS 304# Test Chamber Design Features: 1. ...
Touching Screen Environmental Growth Chambers Stainless Steel SUS 304# Why Choose Us: This machine ...
OEM Low Humidity Temperature And Humidity Environment/Climate Test Chamber 100L peculiarity: *The ...
Electronic Stability Environment Climate Constant Temperature And Humidity Test Chamber 100L Product ...