S/FTP Network Cable CAT8 23AWG 0.60mm BC PVC Jacket

Country/Region china
City & Province shanghai guangxi
Categories Repeater
InquireNow

Product Details

Cat 8 Network Cable, CAT8 Cable, Ethernet Cable CAT8 Application

 

Cat 8, the latest generation of dual shielded (S/FTP) network cable with 4 pairs, supports 2000MHz of bandwidth and reaches up to 40Gb/s at 30 m, especially useful for connecting servers, switches, patch panels, and other devices in the data center.

 

Compatible with Cat 7/7A and Cat 6A, Cat 8.1/8.2 supports 25G Base-T at more than 30 m (tentatively) and 10G Base-T at 100 m, applies in high-speed and bandwidth-intensive locations outside the data center, and meanwhile supports Power Over Ethernet (POE/POE+).

 


Features

 

Cat 8.2, 8-core S/FTP shielded cable, uses pair shield and overall shield structure, with a separate aluminum foil shield for each pair and an overall tinned copper mesh braided shield.

 

This optimizes Near End Crosstalk/Far End Crosstalk (NEXT/FEXT) and Alien Near End Crosstalk (ANEXT) performance, thus resulting in a maximum transmission frequency of 2000MHz.

 

 

Standards

 

GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2

 

 

Technical Details

 

  Transmission PerformanceCat 8.2
Frequency (MHz)4300600100016002000
IL Attenuation (dB/100M)3.710.715.117.92228.5
Near End Crosstalk Attenuation (NEXT, dB)115125.2110.7122.499.392.9
NEXT Power and PS NEXT (dB)808075.872.569.468
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB)7550.844.740.336.234.6
ACR-F Power and PS ACR-F (dB)8052.746.642.238.136.2
Return Loss (RL, dB)2318.916.815.213.813.1

 

Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.

 
 
  Physical Specifications
Conductor Size (nominal value)4×2×0.60 (AWG23)
Outer Diameter of Cable (nominal
value)
8.2mm
Weight (305m, with package,
nominal value)
22kg

 

 

  Electrical Properties
DC resistance (20℃ )
70Ω/km
Earth Capacity≦ 5.6 nF/100m (@1kHz)
100MHz Characteristic Impedance
100Ω±35Ω
Transverse Conversion Loss (TCL)
≥ 55dB-20×lgf (100-2000MHz)
Delay Skew25ns/100m
NVP
74%
Power Over Ethernet (POE)Enhanced Power Over Ethernet under IEEE 802.3at

 

 

  Mechanical Properties
Minimum Bend Radius (dynamic)
34mm
Minimum Bend Radius (static)
68mm
Maximum Installation Tension100N
Anti-Extrusion Capacity1000N/10cm
Anti-Shock Capacity≥ 10 times
Installation Temperature Range-0℃ ~+40℃
Working Temperature Range-20℃ ~+75℃

 

 

  Flammability (PVC)
PVC Flame Resistance
GB/T 18380.12 (IEC 60332-1-2)
Fire Rating CM
UL 1581/ UL 1666

 

 

  Flammability (LSZH)
Flame Resistance (of single wire)GB/T 18380.12 (IEC 60332-1-2)
Flame Resistance (of bunched wires)GB/T 18380.35 (IEC 60332-3-24)
Smoke DensityGB/T 17651 (IEC 61034-1/-2)
Hazardous Halogen GasGB/T 17650.1/.2 (IEC 60754-1/-2)

Hot Products

Modular Electronic Patch Panel 1U 24Port CAT6 CAT6A Intelligent Network Patch Panel​​ Application ...
Fiber Optic Intelligent Patch Panel Intelligent Fiber Panel Product Application It is used in ...
Automated infrastructure management software(AIM) for Data Center Product Application ICT Infrastruc...
Data Center TCRM Series Modular UPS 20 To 200kVA Rack Mounted Modular UPS TCRM series modular UPS ...
10 to 25kVA Split-Type TCHR33 series Rack Mounted UPS Online Double Conversion Product Application ...
UTP Cat 6 Network Cable, Ethernet Cable, CAT6 Cable​ Application TC's UTP-11/21 series, indoor Cat6 ...