SHANGHAI SUNNY ELEVATOR CO.,LTD |
Verified Suppliers
|
|
VVVF 1000kg-5000kg Safe And Reliable Strcture Building Freight Elevator
Stainless Steel VVVF Wide 5000kg 0.25M Freight Lift Elevator Stainless Steel
Load goods gently and arrive at destination floor stably
1. Safe and reliable strcture and high intensity
2. Durable in use and stable in operation
3. Wide opening door and high performance cost ratio
4. Complete in specifications and excellent performance
Load | Speed | Car size | Door opening size | Shaft size | Maximum landing | Maximum lifting height | MRH mm Net height of machine room | ||||||
kg | m/s | CW | CD | CH | OP | OPH | HW | HD | K | S | |||
1000 Non-cut through type | 0.5 | 1400 | 1600 | 2200 | 1300 | 2100 | 2500 | 2080 | 4200 | 1400 | 8 | 30 | 2600 |
1 | 4400 | 15 | 60 | ||||||||||
1000 Cut through type | 0.5 | 4200 | 8 | 30 | |||||||||
1 | 4400 | 15 | 60 | ||||||||||
2000 Non-cut through type | 0.5 | 1700 | 2400 | 2200 | 1500 | 2100 | 2800 | 2880 | 4200 | 1400 | 8 | 30 | 2600 |
1 | 4400 | 15 | 60 | ||||||||||
2000 Cut through type | 0.5 | 4200 | 8 | 30 | |||||||||
1 | 4400 | 15 | 60 | ||||||||||
3000 Non-cut through type | 0.5 | 2000 | 2800 | 2200 | 1700 | 2100 | 3250 | 3280 | 4400 | 1400 | 8 | 30 | 2600 |
1 | 4500 | 15 | 60 | ||||||||||
3000 Cut through type | 0.5 | 4400 | 8 | 30 | |||||||||
1 | 4500 | 15 | 60 | ||||||||||
4000 Non-cut through type | 0.25 | 2000 | 3600 | 2400 | 2000 | 2300 | 3450 | 4080 | 4500 | 1500 | 4 | 15 | 2600 |
0.5 | 8 | 30 | |||||||||||
4000 Cut through type | 0.25 | 4 | 15 | ||||||||||
0.5 | 8 | 30 | |||||||||||
5000 Non-cut through type | 0.25 | 2400 | 3600 | 2400 | 2200 | 2300 | 3800 | 4080 | 4700 | 1500 | 4 | 15 | 2600 |
0.5 | 8 | 30 | |||||||||||
5000 Cut through type | 0.25 | 4 | 15 | ||||||||||
0.5 | 8 | 30 | |||||||||||
6400 Non-cut through type | 0.25 | 2600 | 4300 | 2400 | 2400 | 2300 | 4100 | 4780 | 4800 | 1500 | 4 | 15 | 2600 |
6400 Cut through type | 0.25 | 4 | 15 | ||||||||||
8000 Non-cut through type | 0.25 | 2700 | 5000 | 2500 | 2500 | 2400 | 4300 | 5500 | 5300 | 1600 | 4 | 15 | 2900 |
8000 Cut through type | 0.25 | 4 | 15 | ||||||||||
10000 Non-cut through type | 0.25 | 2800 | 6000 | 2500 | 2600 | 2400 | 4500 | 6500 | 5300 | 1600 | 4 | 15 | 2900 |
10000 Cut through type | 0.25 | 4 | 15 | ||||||||||
Construction Sketch
STANDARD CONFIGURATION
FAQ
1. Is it dangerous for power failure suddenly during the elevator
running?
If it occurs, the elevator will automatically stop due to the
electrical and mechanical safety device. In case of power
failure,elevator brakes will automatically taken. In addition, the
power supply departments such as planned outage, prior notice are
also operating.
2. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of
elevator will automatically restart without any danger. With anti
clamping switch, once the gate touched, this switching action make
the elevator unable to be closed and even reopened. In addition,
closing force is also available here.
3. How the elevator running?
Elevators are operated with a counterweight wire rope through the
(tractor) traction drive, making ups and downs on the guide rail.
4. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.