Home Companies EVERCROSS BRIDGE TECHNOLOGY (SHANGHAI) CO.,LTD.

ODM Steel Cable Stayed Bridges Steel Wire Suspension Bridge For Large Span

EVERCROSS BRIDGE TECHNOLOGY (SHANGHAI) CO.,LTD.

Contact Us

[China] country

Trade Verify

Address: BUILDING C,NO.888,HUANHU WEST 2ND ROAD,LINGANG SPECIAL AREA,CHINA (SHANGHAI) PILOT FREE ZONE,SHANGHAI,CHINA

Contact name:Libby Chen

Inquir Now

EVERCROSS BRIDGE TECHNOLOGY (SHANGHAI) CO.,LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

ODM Steel Cable Stayed Bridges Steel Wire Suspension Bridge For Large Span

Country/Region china
City & Province shanghai shanghai
Categories Ventilation Fans
InquireNow

Product Details

Steel Cable Suspension Cable Stayed Bridges High Strength For Large Span

 

Description:

 

 

Cable-stayed bridge, also known as diagonal bridge, is a kind of bridge where the main beam is directly pulled on the bridge tower with many cables. It is a structural system composed of a pressurized tower, a strained cable and a bent beam body.

 

       

    

 

Span layout

1. Twin tower three span: because of its main span is larger, generally suitable for crossing larger rivers.

 

          

 

 

2. Single tower double span: due to its main hole span is generally smaller than the main hole span of the twin tower three spans, it is suitable for crossing small and medium-sized rivers and urban channels.

 

       

 

 

3.Three-tower four-span and multi-tower multi-span: due to the middle tower top of the multi-tower multi-span cable-stayed bridge and suspension bridge has no end anchor cable to effectively limit its displacement, cable-stayed bridge or suspension bridge with flexible structure adopts multi-tower and multi-span will further increase the flexibility of the structure, which may lead to excessive deformation.

 

           

 

4. Auxiliary pier and side lead span

 

        

                                        

Live load often produces a large positive bending moment near the end of the side span beam, and leads to the rotation of the beam body, and the expansion joint is easy to be damaged. In this case, it can be solved by lengthening the side beam to form the lead span or setting the auxiliary pier.

 

In addition, the installation of auxiliary piers is also convenient for the cantilever construction of cable-stayed bridge, that is, double cantilever construction to the auxiliary pier is equivalent to single cantilever construction, and its swing is small and safer.

 

 

The cable-stayed bridge is mainly divided into three parts: main beam, cable tower and stay cable.

The main beam generally adopts concrete structure, steel-concrete combination structure.

Steel structure or steel and concrete mixed structure.

Cable tower -it adopts concrete, steel-concrete combination or steel structure. Most of them are concrete structures.

Stay cable - is made of high strength material (high strength steel wire or steel strand).

 

 

 

 

Cable tower arrangement of cable-stayed bridge

 

The form of the cable tower

Cable tower is the main structure to express the personality and visual effect of cable-stayed bridge, so the aesthetic design of cable tower should be paid enough attention.

The tower design must be suitable for the arrangement of the cable, the force transmission should be simple and clear, and the tower should be under axial pressure as far as possible under the action of dead load.

 

      

 

(a) It is single column type main tower, which is simple in structure.

(b) It is A-shape.

(c) It is inverted Y type, which has high stiffness along the bridge and is conducive to withstand the unbalanced tension of the cable on both sides of the cable tower. The A-shape can also reduce the negative bending moment of the main beam at this point.

 

The layout of the cable tower cross bridge direction can be divided into single column type, double column type, door type or H type, A type, gem type or inverted Y type.

 

          

 

The vertical and horizontal arrangement of the pylon is single-column type, which is only suitable for single-plane cable-stayed bridges. When it is necessary to strengthen the wind stiffness of the transverse bridge, the g or h type can be used. b~d is generally suitable for the case of biplanar cables. e, f, and i are generally suitable for cable-stayed bridges with double diagonal cable surfaces.

 

The height to span ratio of the tower

The height of the tower determines the stiffness and economy of the entire bridge.

 

     

 

 

Dragline arrangement

 

Cable-plane position

There are generally three types of cable surface positions, namely (a) single cable plane (b) vertical double cable plane (c) oblique double cable plane and multiple cable plane.

 

      

 

Single cable plane: Box section with large mechanical torsional stiffness. The advantage is that from a perspective, the cable does not work against torsion. Therefore, the main beam should be used on the bridge floor with a wide field of view.

Vertical double cable plane: The torque acting on the bridge can be resisted by the axial force of the cable, and the main beam can use a section with lower torsional stiffness. Its wind resistance is relatively weak.

Diagonal double cable plane, which is particularly beneficial for the bridge deck beam body to resist wind torsional vibration (diagonal double cable plane limits the transverse swing of the main beam). Inclined double cable faces should adopt Y, A or twin pylons. If the span is too small, consider the view, should not be adopted. Generally, it is used when the span is greater than 600m, or when it cannot meet the requirements of wind resistance.

 

Cable-plane shape

 

There are three basic types of cable surface shapes as shown, namely (a) radial shape, (b) harp shape and (c) sector. Their respective characteristics are as follows:

Stay cable elevation layout

a) radiative shape. b) Harp shape. c) Sector.

 

(a) The radial arrangement of the cable is evenly distributed along the main beam, while on the tower it is concentrated at the top point. Because the average intersection angle between the cable and the horizontal plane is large, the vertical component of the cable has a large supporting effect on the main beam, but the structure of the anchorage point on the top of the tower is complicated.

b) The cable in the harp-shaped arrangement is arranged in parallel, which is more concise when the number of cables is small, and can simplify the connection structure of the cable and the cable tower. The anchorage points on the tower are scattered, which is beneficial to the force of the cable tower. The disadvantage is that the inclination angle of the cable is small, the total tension of the cable is large, so the cable is used more.

(c) The sector arrangement of the cable is not parallel to each other, it has the advantages of the above two arrangements, and has been widely used in design.

 

 

   

 

Layout of cable spacing

The arrangement of cable distance can be divided into "thin cable" and "dense cable".

 

The advantages of the dense cable system are as follows:

1. The cable distance is small, the main beam bending moment is small (the cable distance on the main beam is generally 4-10m concrete beam, steel beam is 12-20m).

2. The cable force is small, the anchoring point structure is simple.

3. The change of stress flow near the anchoring point is small, and the reinforcement range is small.

4. Conducive to arm erection.

5. Easy to change cable.

6. When the cable-stayed bridge is erected by cantilever method, the cable spacing should be 5 ~ 15m.

 

The structural system of cable-stayed bridges can be divided into the following different ways:

According to the combination of tower, beam and pier: floating system, semi-floating system, tower beam consolidation system and rigid structure system.

     

        

 

According to the continuous mode of the main beam, there are continuous system and T-structure system.

According to the anchoring method of the cable, it is classified as self-anchoring and ground anchoring.

 

 

Low tower partial cable-stayed bridge system

Classification by tower height: conventional cable-stayed bridges and partial cable-stayed bridges with low towers.

 

         

    The mechanical performance of the low-pylon partial cable-stayed bridge is between the beam bridge and the cable-stayed bridge.

 

 

The structure of the main beam of the cable-stayed bridge

 

The function of the main beam has three aspects:

(1) Distribute the dead load and live load to the cable. The smaller the stiffness of the beam, the smaller the bending moment.

(2) As part of the whole bridge together with the cable and tower, the force borne by the main beam is mainly the axial pressure formed by the horizontal component of the cable, so it needs to have sufficient stiffness to prevent buckling.

(3) Resist transverse wind and seismic loads and transmit these forces to the substructure.

 

When the cable distance is large, the main beam is designed by the bending moment control. 

In addition, it should be considered that the main beam has sufficient strength and stiffness to replace the cable with a reduced live load. It is also necessary to consider that the structure still has enough safety reserve when the individual cable breaks or exits the work accidentally.

 

Suitable span of main beams of different materials

The main beams of cable-stayed bridges are composed of four different ways:

1. Prestressed concrete beams, known as concrete cable-stayed bridges, economic span less than 400m.

2. Steel-concrete composite beam, called composite beam cable-stayed bridge, economic span 400 ~ 600m.

3. All steel main beam, known as steel cable-stayed bridge, economic span more than 600m.

4. The main span is a steel main beam or a steel-concrete composite beam, and the side span is a concrete beam, which is called a hybrid cable-stayed bridge with an economic span of more than 600m.

 

 

Cable tower of the cable-stayed bridge

 

The composition of the cable tower components: the tower plays a decisive role in aesthetics: careful selection of shapes, drawing size proportions, using models, and local optimization.

The main component of the cable tower is the tower column, and there are also beams or other connecting members between the tower columns.

The former is a bending beam for setting the support of the main beam, and a pressure rod beam or a tie rod beam at the bend of the tower column. The latter is the top beam of the tower and the middle beam of the tower column without turning.

 

              

 

 

The structure of the concrete tower

Generally, solid body cable tower is suitable for small and medium span cable-stayed bridge, for small span can be used equal section, for more than medium span cable-stayed bridge column can be used hollow section.

 

      

The structure of the rectangular section cable tower is simple, and its four corners should be made of chamfer or rounded corners to facilitate wind resistance. The H-section pylon is the most unfavorable against the wind. Octagonal section is conducive to the configuration of closed circumferential prestressed tendons, but the structure is slightly complicated.

 

The H-shaped section on the facade cannot expose the anchor head, which improves the appearance, but at the same time creates four cable planes.

This problem can be solved by using H-section towers with two cable planes. However, using one form will cause the bridge tower to be twisted, and using two forms to cross the upper and lower settings can avoid the bridge tower to be twisted but not beautiful.

 

 

Stay cable of the cable-stayed bridge

 

The construction of stay cable

The structure of dragline is basically divided into two categories: integral installation cable and dispersed installation cable. The representation of former is parallel wire cables with cold-cast anchors, while the representation of the latter is parallel wire cables with clip anchors.

 

1.Parallel wire cable with cold cast anchor 

 

        

 

2.Parallel steel cable with clip anchor

 

  

 

The steel wire in the parallel wire cable is replaced by a steel strand of equal section, which becomes a steel strand cable.

Single steel strand cable weight is light, transport and installation is convenient, but the anchor head needs on-site protection, quality assurance difficulty increases.

 

The mechanism of action is that the long cable is converted into a relatively short cable through the connection, so that the vibration base frequency of the cable is increased, and the vibration of the cable is suppressed.

 

Anchorage of the cable

1. Anchorage of the cable on the beam

The vertical component is balanced by the stiffening oblique bar.

 

2. Anchoring of the cable on the cable tower

Damping of the cable

The wind-induced vibration of the cable is common in all kinds of span and types of cable-stayed bridges, and the vibration of the cable is easy to cause fatigue and damage. At present, the main measures to reduce the vibration of the cable of the cable-stayed bridge are as follows:

(1) Pneumatic control method.

(2) Damping vibration reduction method.

(3) Changing the dynamic characteristics of the cable.

 

(1) Pneumatic control method

The original smooth surface of the cable is made into a non-smooth surface with spiral ridges, bar ridges, V-shaped grooves or circular concave points. The bump on the cable surface can prevent the formation of the cable waterline when it rains, thus preventing the occurrence of rain vibration.

(2) Damping vibration reduction method

The mechanism of damping vibration reduction method is to increase the damping ratio of the cable by installing damping device so as to restrain the vibration of the cable. According to the relationship between the damping device and the cable, the damping device can be divided into an internal damper placed in the sleeve and an external damper attached to the cable.

(3) Method of changing cable dynamic characteristics

Several cables are connected to each other by couplings (cable clamps) or auxiliary cables, which may be of a much smaller diameter than the main cable.

 

 

Characteristics of cable-stayed Bridges:

Great crossing ability.

The height of the beam is small.

The horizontal component of the cable is balanced by the axial pressure of the main beam.

 

 

The construction method of cable-stayed bridge can be summarized as follows: there are support construction method, push construction method, rotary construction method and cantilever construction method (cantilever assembly and cantilever pouring).

 

 

The main components of a cable-stayed bridge are:

 

Deck: The bridge deck is the roadway or walkway that carries the traffic or pedestrians across the span. It can be made of various materials such as concrete, steel, or composite materials.

Towers: Cable-stayed bridges have tall towers that rise above the deck level. These towers support the weight of the deck and transmit the loads to the ground. The towers are typically made of concrete or steel and are designed to withstand the forces exerted by the cables.

Cables: The cables of a cable-stayed bridge are the primary load-bearing elements. They extend from the towers and attach to the deck at specific points. The cables are usually made of high-strength steel or other strong materials. They are tensioned to provide support and stability to the bridge deck.

Pylons: Pylons are the structures that connect the cables to the towers. They are designed to distribute the forces from the cables to the towers in an efficient manner.

 

 

The advantages of cable-stayed bridges:

 

Easy to cantilever construction.

The size of the beam body is small, and the crossing capacity of the bridge is large.

Less restricted by the bridge clearance and deck elevation.

There is no need for centralized anchorage structure like suspension bridge.

 

 

Application of cable-stayed bridges:

Road and Highway Bridges: Cable-stayed bridges are frequently used for road and highway crossings. They offer advantages such as long-span capabilities, cost-effectiveness, and aesthetic appeal.

Pedestrian and Bicycle Bridges: Cable-stayed bridges are also utilized for pedestrian and bicycle crossings.

Highway cable-stayed bridge, railway cable-stayed bridge.

 

 

Evercross Steel Bridges Overview :

EVERCROSS STEEL BRIDGE SPECIFICATION
EVERCROSS
STEEL BRIDGE
Bailey bridge (Compact-200, Compact-100, LSB, PB100, China-321, BSB)
Modular bridge (GWD, Delta, 450-type, etc.),
Truss Bridge, Warren bridge,
Arch bridge, Plate bridge, Beam bridge, Box girder bridge,
Suspension bridge, Cable-stayed bridge,
Floating bridge, etc.
DESIGN SPANS10M TO 300M Single span
CARRIAGE WAYSINGLE LANE, DOUBLE LANES, MULTILANE, WALKWAY, ETC
LOADING CAPACITYAASHTO HL93.HS15-44, HS20-44, HS25-44,
BS5400 HA+20HB, HA+30HB,
AS5100 Truck-T44,
IRC 70R Class A/B,
NATO STANAG MLC80/ MLC110.
Truck-60T, Trailer-80/100Ton, etc.
STEEL GRADEEN10025 S355JR S355J0/EN10219 S460J0/ EN10113 S460N/BS4360 Grade 55C
AS/ NZS3678/ 3679/ 1163/ Grade 350,
ASTM A572/A572M GR50/GR65
GB1591 GB355B/C/D/460C, etc.
CERTIFICATESISO9001, ISO14001, ISO45001, EN1090, CIDB, COC, PVOC, SONCAP, etc.
WELDINGAWS D1.1/AWS D1.5
AS/NZS 1554 or equivalent
BOLTSISO898, AS/NZS1252, BS3692 or equivalent
GALVANIZATION CODEISO1461
AS/NZS 4680
ASTM-A123,
BS1706
or equivalent
 

 


 

 



Hot Products

Convenient Transport And Speedy Erection Cable Stayed Bridges Description: Cable-stayed bridge, also ...
Description: Cable-stayed bridge, also known as diagonal bridge, is a kind of bridge where the main ...
Description: Cable-stayed bridge, also known as diagonal bridge, is a kind of bridge where the main ...
Description: Cable-stayed bridge, also known as diagonal bridge, is a kind of bridge where the main ...
Description: Cable-stayed bridge, also known as diagonal bridge, is a kind of bridge where the main ...
Customized Cable Stayed Bridges High Strength Big Loading Capacity Description: Cable-stayed bridge, ...