Home Companies ZHANGJIAGANG MEDPHARM MACHINERY LTD.

Biosafety Large Capacity Laboratory Sterilizer With Electronic Circuit Safety Protection

ZHANGJIAGANG MEDPHARM MACHINERY LTD.

Contact Us

[China] country

Trade Verify

Address: B631, HUAFANG INTERNATIONAL MANSION, No.178 CHENGBEI STR., ZHANGJIAGANG, JIANGSU, PRC, 215600

Contact name:Juliet

Inquir Now

ZHANGJIAGANG MEDPHARM MACHINERY LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Biosafety Large Capacity Laboratory Sterilizer With Electronic Circuit Safety Protection

Country/Region china
City & Province jiangsu
InquireNow

Product Details

 

Biosafety Large Capacity Laboratory Sterilizer With Electronic Circuit Safety Protection

 

 

Description

 

All models can be configured for either single entry or pass-through. All Medpharm Systems

models are fitted with a wide selection of features as standard, all designed to ensure

optimum performance.

 

Capacities: 1000, 1200 and 1500 liters

Pass-Through: Available throughout range
Section: Rectangular
Loading: Front 
Heating Source: Integral/stand-alone steam generator or direct steam supply

 

Features

 

  • Special design for BSL3 and BSL4 laboratories
  • Extreme process reliability
  • User-friendly HMI
  • Parameters could be easy adjusted for perfect compliance with customer requirements
  • Efficient drying based on a high performance vacuum system
  • Minimal media consumption
  • Strictly isolated technologies adopted to ensure safety
  • No recontamination for environment and human being

 

Parameters

 

Model

Chamber Size

Overall Size

Steam

Water

Power

W*H*D mm

W*H*D mm

Kg/cycle

Kg/cycle

KVA

MDL-1.0

680*1180*1250

1350*2000*1590

40

100

4

MDL-1.2

680*1180*1500

1350*2000*1840

45

120

4

MDL-1.5

680*1180*1870

1350*2000*2210

50

150

4.5

 

Biosafety And Waste Treatment Facilities

 

Medpharm supplies full sterilization solutions for the treatment of bio hazardous materials and waste.

 

Medpharm autoclave sterilizers can be customized to meet the specific requirements of laboratories

classified as BSL3/4 (Bio Contaminant Level 3 or 4) where harmful pathogens and viruses that

leave the sterilizer prior to disposal must be fully sterilized. The bio-hazardous waste sterilization cycle will efficiently process any load without risk to the environment.

 

These autoclaves are supplied with a thermal effluent decontamination stage that sterilizes chamber air and waste water prior to their release into the atmosphere and drain.

 

An additional sterilization system is incorporated into the autoclave which prevents bio-hazardous

aerosol generation.

 

During the air removal phase, the exhaust, aerosol and condensation pass through a secondary sterilization treatment that sterilizes the effluent.

 

During the heating and sterilization phases all effluent is not allowed to exit the chamber until the sterilization phase is fully complete.

 

Protecting People And The Environment

 

There are many types of materials in laboratories, hygiene standards are extremely high. Perfect sterilization processes are the prerequisite for safety in laboratory operation. Suitable methods have to be used to validate sterilization processes in terms of the desired effect, because perfect sterilization results can only be achieved by precisely matching sterilization processes to the material to be sterilized.

 

 

Brochure load down from here

Medpharm medical large steam autoclave brochure.pdf

Hot Products

High Vacuum Degree Sterilizers Autoclave With Low Noise Water-ring Vacuum Pump For Silence ...
Rectangular Chamber With Smooth Round Corners And Jacket Medical Instrument Sterilizer Machine Model ...
Liquid Cycle With Pressure Ballasting Steam Sterilization Using Autoclave Feature 1. Hinged door ...
High Pressure High Vacuum Autoclave Sterilizers Ensuring Perfect Sterilization For Hospital And ...
Overpressure Protection Autoclave and Sterilizers With Safety Door System Main parameter PLC based ...
Overpressure protection autoclave and sterilizers with safety door system Main parameter: PLC based ...