Built In Micro Printer Veterinary Autoclave With Bowie Dick Test And Vacuum Leak Test

Country/Region china
City & Province jiangsu
InquireNow

Product Details

 

Built In Micro Printer Veterinary Autoclave With Bowie Dick Test And Vacuum Leak Test

   

Description

 

Steam Sterilizers are configured for prevacuum sterilization of heat- and moisture-stable materials used in medical centers. These units can be equipped with prevacuum, Steam Flush Pressure Pulse (SFPP), gravity, liquid, and daily air removal test cycles which use, for example, a Bowie Dick test pack or a vacuum test to determine the effectiveness

of removing air from a sterilizer chamber.

 

Features

 

  • 304 stainless steel construction - chamber and jacket
  • Fewer welds, resulting in less metal fatigue
  • Fully jacketed chamber to optimize even chamber heating and minimize condensation
  • Motorized hinged door with easy-open locking mechanism
  • Steam-activated gasket to lessen the possibility of air entering the chamber
  • Easy access and loading
  • Easy-to-align loading system eliminates operator handling of hot loads

 

Testing Cycles

 

Bowie-Dick Test Cycle:

 

This cycle is used for conducting Bowie-Dick tests. Recommended load is a properly prepared

Bowie-Dick test pack. Preprogrammed cycle parameters cannot be adjusted by the user.

  • Sterilize temperature: 134°C
  • Sterilize time: 4 minutes 
  • Dry time: 3 minute

 

Vacuum Leak Test:

 

 This cycle is used for testing the vacuum integrity of the sterilizer piping. Sterilizer chamber  must be empty while running this test cycle. All timing is preprogrammed and cannot be adjusted

 

Specifications

 

Model

MD-0.36

Door type

Double door type

Door open method

Motorized Hinge Door

Chamber volume

360L

Chamber Size  

600*600*1000mm

Overall Size         

1350*1800*1340mm

Net Weight            

800kg

Steam               

25Kg/cycle

Water           

40Kg/cycle

Power(KVA)

2KVA

Sterilization temperature rage

105°C to 134°C

Sterilization time rage

 0---99 minutes

Vacuum times

 0---9 times

Drying time

 0---99 minutes

Components
 

SS304 built-in steam generator(Optional)

Touch screen display

PLC control system

High effective liquid-ring vacuum pump

 

 

 

Brochure load down from here

Medpharm medical large steam autoclave brochure.pdf

Hot Products

High Vacuum Degree Sterilizers Autoclave With Low Noise Water-ring Vacuum Pump For Silence ...
Rectangular Chamber With Smooth Round Corners And Jacket Medical Instrument Sterilizer Machine Model ...
Liquid Cycle With Pressure Ballasting Steam Sterilization Using Autoclave Feature 1. Hinged door ...
High Pressure High Vacuum Autoclave Sterilizers Ensuring Perfect Sterilization For Hospital And ...
Overpressure Protection Autoclave and Sterilizers With Safety Door System Main parameter PLC based ...
Overpressure protection autoclave and sterilizers with safety door system Main parameter: PLC based ...