Horizontal Durable 1500 Liter Large Medical Instrument Steam Sterilizer With Pneumatic Door
 
Features
 

  • All sterilizer models are available in single-door and double-door versions
  • Hinged door(-s) with automatic locking device
  • Chamber and process piping made of stainless steel AISI 316L
  • Motorized Hinge Door has internal side in stainless steel AISI 316L with sanitary polishing finish for durability and ease of cleaning
  • Suitable for floor level installation
  • Colour touch screen panel HMI
  • Output of sterilization parameters on the built-in printer
  • 3 integrated sterilization programs and wide range of customizable ones, allowing to select sterilization time and temperature, drying and cooling
  • 2 test programs (Leak test and Bowie-Dick test for control of steam penetration into porous materials)
  • A wide range of parameter adjustment is available for each program

 
Main Parameters
 

Model

MD-1.5

Door number

Single or double door

Door type

Motorized Hinge Door

Chamber volume

1500 liters

Chamber Size  

680*1180*1870mm

Overall Size         

1450*2000*2210mm

Net Weight            

2150kg

Steam               

50Kg/cycle

Water           

150Kg/cycle

Power(KVA)

4.5KVA

Sterilization temperature rage

105°C to 134°C

Sterilization time rage

 0---99 minutes

Vacuum times

 0---9 times

Drying time

 0---99 minutes

Compressed air

Oil free compressed air is important to the autoclave’s running.

Oil free silence air-compressor is optional for user’s selection.

Compressed air pressure: 0.5---0.8MPa

 
Application
 
Sterilizer designed to meet the most critical sterilization parameters and normative parameters of manufacture and security, being able to sterilizer and dry materials of density such as surgical fields and clothes, packed or unpacked instruments and tools, glasses, gloves, syringes, rubbers, liquids in open vials with calculation, mainly necessary in quality control laboratory with specific program for Bowie & Dick Test and Leak Test. Recommended for use in hospitals, emergency rooms and outpatient care centers, medical clinics, medical analyses laboratories. 
 
Sterilization Cycles
 

All parameters such as number of deep vacuum pulses, sterilization temperature and time for
each stage are user configurable.

Cycle for Packages:

For the sterilization of textiles and of density 
materials. The cycle profile presents load
 conditioning phase through vacuum and steam 
pulses; exposure phase at the temperature of 
134°C and drying phase under mechanical vacuum. 

Cycle for Latex:

Sterilization cycle for thermo sensitive materials 
such as rubber bungs, polypropylene bottles, 
surgical gloves, silicone tubes among others. 

Cycle for Instruments:

Suitable for sterilization of surgical instruments, 
stainless steel materials or other surface 
materials such as glassware, bowls kidney and 
utensils in stainless steel vats and others. By 
default, the cycle presents load conditioning 
phase through vacuum and steam pulses; 
exposure phase at 132 C of temperature and 
under mechanical vacuum drying phase. 

Cycle for liquids in airtight packaging:

The cycle profile presents conditioning phase 
through a single steam pulse: sweeping; exposure; 
121°C temperature exposure phase and slow 
cooling phase with pressure control inside the 
chamber with end of cycle defined by temperature. 

Cycle for liquids (Flasks and Culture medium):

For liquids in not airtight packaging. Cycle profile
 presents conditioning phase through a single 
steam pulse: sweeping; 121°C temperature 
exposure phase and slow cooling phase with 
cycle end defined by temperature. 

Cycle for Bowie & Dick Test

To determine the capacity of the equipment in 
providing the withdrawal of air and penetration 
of the steam in the load to be sterilized.

Cycle for Leak Test

Indicated for the inspection of tightness of the 
sterilization chamber. The cycle consists of vacuum 
pulse, accommodation time and sealing inspection time. 

Cycle for user “A”:

Indicated for sterilization with totally open programming,
 similar to the density cycles

Cycle for user “B”:

 Indicated for sterilization with totally open programming 
similar to the liquids cycles

 


 
Brochure load down from here
Medpharm medical large steam autoclave brochure.pdf












































Hot Products

High Vacuum Degree Sterilizers Autoclave With Low Noise Water-ring Vacuum Pump For Silence ...
Rectangular Chamber With Smooth Round Corners And Jacket Medical Instrument Sterilizer Machine Model ...
Liquid Cycle With Pressure Ballasting Steam Sterilization Using Autoclave Feature 1. Hinged door ...
High Pressure High Vacuum Autoclave Sterilizers Ensuring Perfect Sterilization For Hospital And ...
Overpressure Protection Autoclave and Sterilizers With Safety Door System Main parameter PLC based ...
Overpressure protection autoclave and sterilizers with safety door system Main parameter: PLC based ...