New upgrades to simplify,to meet customer needs. Increase the supply anti-reversefunction. The use of opto isolated input and output,enhanced anti-jamming
capabilit consumption. Set parameter after power for ever memories. Signal terminal voltage signal can be maintained for a longtime. to ensure stability,industrial grade board,class PLC. Product parameters: Size:64.2mm*34.8mm*18.5mm. Relay Specifications:AC 220V 10A or DC 30V 10A. Quiescent Current:20mA,Operating Current:50mA. Working voltage:10~16V (if other ranges can be customized). Signal voltage:4V~20V (if other ranges can be customized). life:about100,000times,Working temperature:-40~85'C.
Selection:After power on,long press K12 seconds later into the
select function mode,P1-1~P1-4forchoose. P1-1 operating modes:a
signal to trigger relay, time is up,the relay disconnect users,You
can set relay time T,click K2 the hundreddigital tube starts
flashing,then press K3, the hundred digital change;click K2 ten
digital tube starts flashing,then press K3,ten digit changes;click
K2 bit digital tube starts flashing, then press K3, single-digit
change;then click K2,; digital pipe does not blink,then press the
K3, shifting the decimalpoint,the decimalpointin abitindicates
0-999minutesin ten represents 0 to 99.9 seconds withou
tadecimalpointrepresents 0-999 seconds;goodchoice,bringing the time
setting is completed.Short press K1,enterfunction offine-tuning
settings,triggerthedefaultdelayperiod is invalid, press K1, during
the delay trigger active(re-timing),clickon the K1, during the
delay reset (timer turned off,the relay reset) press again to
repeat the default settings for the first time. P1-2 operating
modes:Asignal trigger ,digital countdown begins,X seconds
after,there lay open Y seconds,then close.Users can set the relay
time X,Y;P1-1different time settings similar to the blue lights
that set the relay time,blue light indicates setting relay off
time. Short press K1, enter function offine-tuning the set,the
default trigger is invalid during the delay,pressK1,during the
delay trigger active(re-timing),then click the first repeat default
settings. P1-3 operating modes:Open X seconds,disconnect Yseconds,
infinite loop.Users can set the relay timeX,Y;time setting similar
to P1-2.Short press K1,enter function offine-tuning set,The default
function is:set up an electric circuit the relay first open, press
the K1,there lay first close.Press again to repeat the default
functionality. P1-4 operating modes:a signal to trigger the relay
open but do not start the timer,when the trigger signal
disappears,digital count down begins,X time after,the relayclose;
During the delay,again to the signal,digital count down canceled,
stays energized, the signal disappears, restart count down;
(equivalentto release the button to start timing, commonly usedin power-offdelay).Users canset the relay time X; time setting
similar to P1-1.
# 1.25-36V Voltage Board MOSFET Switch DSN6000AUD Package Included : 1PCS x DC12V Delay Timer Control Switch Module |