Med Accessories Technology Dongguan Co., Ltd. |
Verified Suppliers
|
|
Compatible Nelllcor Adult soft Direct-Connect SpO2 Sensor
Manufacturer | Model |
---|---|
Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
CAS Med | 511, 740 |
Cardio Aid | 200 |
Covidien > Nellcor | N-3000, N-395, N-390, N-560, N-550,N-595, N-6000, N-600, N-600x, NPB-290, NPB-295, Oximeters that require Nellcor
OxiMax sensors, Symphony N-3000 |
Criticare | 506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506N3, 506NV3, 506NVP3 |
DRE | Waveline |
Datex Ohmeda | Cardiocap/5, enGuard CM5 |
Digicare | LW600 |
Fukuda Denshi | Dynascope DS-7100 |
GE Healthcare > Critikon > Dinamap | Carescape B650, Carescape V100, E-NSAT, M-NSAT Modules, Pro 1000,
Pro 1000 V3, Pro 200, Pro 300, Pro 300V2, Pro 400, Pro Series, Pro
Series V2, ProCare, ProCare 200, ProCare 300, ProCare 400, ProCare
Ausculatory 400, ProSeries V2, V300 |
Huntleigh | All |
Invivo | Escort II OPT30 Prism, MDE Escort Prism, T8 |
Mediana | M30, YM6000 |
Midmark > Cardell | 9403, 9500HD |
Mindray > Datascope | Accutor V, Accutorr Plus, Accutorr Plus (Nellcor), Accutorr V, Duo,
EPM4, Passport 2, Passport 2LT, Passport V, Passport XG, Spectrum,
Spectrum OR, Trio, V-Series, V12, V21 |
Nihon Kohden | BSM-2300, BSM-2304A, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100 |
Omron > Colin | BP-306, BP-508, BP-808, BP-88, BP-88S, BP-S510, Press-Mate, T105NXM |
Oridion | Capnostream 20 |
Equipment: * Connect the sensor cable to the appropriate device (pulse
oximeter) * Turn on the device and check correct operation by
consulting the monitor's operating instructions. *To ensure proper
operation of the monitor, please connect and disconnect the sensor
cable from the monitor cable. Use correctly and safely
The sensor and its connecting cable require system inspection at
least once or more per month, depending on frequency of use and
sanitization of the cable *Visual inspection (appearance of
insulator, connector contact pins, etc.) *Verification of
mechanical integrity of the connector Do not use and discard any
sensor with mechanical or electrical defects. The operating
conditions of the SpO2 sensor and its cable are as follows:
*Ambient temperature: 0° to +40° C
*Relative humidity: 0 to 80%
*Atmospheric pressure: 860 to 1060 HPa For use of SpO2 sensors and
their connecting cables in departments where compliance with
sterility levels is required, Med Accessories recommends the
following cleaning, disinfection or sterilization methods:
Cleaning equipment: Clean the sensor and its connecting cable with
warm soapy water. The probe and cable must be cleaned with a soft
cloth moistened with soapy water or 70% isopropyl alcohol. Be
careful to avoid damage
Visual indicators and detector surfaces. Allow the probe and cable
to dry thoroughly before use. Do not use any abrasives or chemicals
other than 70% isopropyl alcohol
Do not irradiate, autoclave, soak, or immerse the probe in any type
of solution. Keep the probe clean and dry. Under the conditions of
use advocated in these operating instructions, the average life
expectancy of the SpO2 sensor is more than one year.
During the Warranty Period: Med Accessories offers a warranty on its products that includes replacement for any quality-related issues that arise within the specified warranty period. This warranty applies to normal conditions of use. If a quality issue occurs during the warranty period, Med Accessories will provide replacement service to correct the problem.
Compatibility Guarantee: Med Accessories understands the importance of compatibility between its products and the devices with which they are intended to be used. If after purchasing a Med Accessories product it is discovered that the product is incompatible with the specific device for which it was intended, Med Accessories will take immediate action. They will provide a new replacement that is compatible with the customer's device or provide a refund on the purchase.