RF Wireless Grouping Microwave Movement Sensor HNS106RF 24VDC

Country/Region china
City & Province shenzhen guangdong
InquireNow

Product Details

Model name: HNS106RF       12V DC RF Wireless grouping microwave sensor 

 

This model is a super small, only 46mm in diameter, and it is a small RF wireless motion sensor. It owns 0-10v dimming,

RF wireless grouping two functions, remote control setting, easy operation and intelligent grouping on requierement. 

 

Advantage: 

1.  Ideal for industrial lighting application. Some retrofit project /parking garage / staircase / corridor applications,

     easy installation, free of wiring.

2. Two channels, more fixtures can be connected. 

3. Customized service: YES

 

Product information:

Input voltage: 12V~24V DC Input current: ≥50mA
RF frequency:868MHz/ 915MHz
RF transmission distance :

max. 50m in open area

Function:

0-10v dimming, RF wireless grouping, daylight monitoring function 3 in 1


RF Grouping ( via remote control )

 

Step 1 LearnShort press “Learn” button, the LED indicator flickers three times and the lamp flickers once when the receiver unit successfully starting grouping mode. The LED indicator of the receiver unit flickers (every 2 seconds for 3min).This grouping mode will last for 3min, second short press on it will quit the grouping mode.
Step 2  SendShort press “Send” button to the commander unit, it will flicker quickly three times and the lamp flickers once to start a 5s RF signal sending, and then 2 times ( the LED
indicator flickers three times + the lamp flickers once ) to indicate finish of it.
After the RF signal, the LED indicator of the receiver unite will flicker three times and the lamp flicker once to indicate the success of grouping
Step 3 Erase

Long press “Erase” button for 5s to the sensor unit, the LED indicator will flicker three times and the lamp flickers once, to indicate the success of erasing.

 

Note:
1. If you want the sensor to work as both commander and receiver, you need to repeat the “learn” and “send” process again with the identification exchanged.
2. Each receiver can learn up to max. 32 commanders, late commanders beyond 32pcs will automatically substitute earlier ones.

 

 

 

 

Hot Products

Model name: HNM01 5.8GHz microwave Motion Sensor Module This module is a small size intelligent 5.8G ...
Model name: HNM02 Microwave Motion Sensor Module This model is a small microwave motion sensor ...
Model name: ANT03 5V DC input small Microwave motion sensor module This model is a intelligent ...
Model name: HNM01 5.8GHz Microwave Motion Sensor Module This model is a 5.8GHz microwave motion ...
Model nameL HNM02 5.8GHz small microwave motion sensor module This mode is a super small size ...
Model name: HNS201DC Dry contact microwave motion sensor switch . This model is a 12V DC input, dry ...