Ferrite Inverter Welding SMPS Flyback Transformer
ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted:
PARAMETER | TEST CONDITIONS | VALUE |
D.C. RESISTANCE 1-3 | @20°C | 0.160 ohms max |
D.C. RESISTANCE 6-4 | @20°C | 0.400 ohms max |
INDUCTANCE 1-3 | 100KHz,10mVAC,Ls | 370uH min. |
DIELECTRIC 1-6 | 6250vac,1 second | 5000Vrms, 1 minute |
TURNS RATIO | (6-4):(1-3) | 2:1±2% |
GENERAL SPECIFICATIONS:
- OPERATING TEMPERATURE RANGE: -40°C TO +85°C .
- CURRENT RATING: 1A
- VOLTAGE-TIME: 20Vus for Unipolar operation
40Vus for Bipolar operation
- SWITCHING FREQUENCY: 150KHz min.
- 11mm min. creepage and clearance between PRI & SEC.
- COPLANARITY: All 6 terminals must lie on a plane within .004[.10]
of Surface A after leaf tinning,
- Designed to comply with the following requirements as defined by
IEC60601-1(ed): Amendment 1: -Providing two means of Patient
Protection up to a working voltage of 360VAC.
- Complies with the following requirements as defined by IEC60950-1,
EN60950-1, UL60950-1/CSA60950-1 and AS/NZS60950-1: -Reinforced
insulation for a primary circuit at a working voltage of
55-VAC, overvoltage Category II,Pollution Degree 2, up to 2km above
sea level Designed to comply with the following requirements
as defined by IEC60664-1: -Reinforced insulation for a primary
circuit at a working volatage of 44VAC up to 2km above sea level,
- Designed to comply with the following requirements as defined by
IEC61010-1: -Reinforced insulation for a line to neutral
voltage up to 1000Vrms, Overvoltage Category ll, up to
2km above sea level. -Reinforced insulation for a line to
neutral voltage up to 600Vrms, Overvoltage Category ll, up to
5km above sea level.
- Complies with the following requirements as defined by IEC62368-1,
UL/CSA62368-1 and EN62368-1: - Reinforced insulation for ES3,
operating frequency above 30KHz, working voltage up to 550Vrms,
1600Vpeak , Overvoltage Category ll, Pollution Degreeii , and up
to 2km above sea level.
- Qualified to AEC-Q200
Ferrite Inverter Welding SMPS Flyback Transformer
HOW TO ORDER
1. Please send me your datasheet or part number you need.
2. We will offer the replacement quotation for your reference
3. The free samples are available for your approval.
4. After sample testing, we will step into the mass order.
5. The Proforma Invoice will send for your confirmation
6. After the goods finished, we send the goods to you and tell you
the tracking number.
7. We will track your goods until you receive the goods.
Remarks:
1. Sample orders are avaliable.
2. Price is negotiable for orders of large quantity.
3. Customized orders (OEM/ODM orders) are avaliable.
4. Contact us for available flavors list. International
Certifications:
1. ISO9001:2008
2. UL
3. Reach
4. RoHs