0.5VV DC 45Hz ~ 65Hz Digital Clamp Infrared Themometer

 

3.2 Technical indicators

 

Environment temperature:23±5℃ Relative humidity:<75%

 

3.2.1 AC Current

 

RangeResolutionAccuracy
6A0.001A±(3.0% + 20)
60A0.01A±(2.5% + 8)
400A0.1A±(2.5% + 10)

 

- Min input current:0.02A AC

- Max input:400A AC

- Frequency:45Hz ~65Hz

- When ac current is measured, the meter automatically opens an internal low-pass filter to filter out high-frequency current.

 

3.2.2 DC voltage

 

RangeResolutionAccuracy
6V0.001V±(0.5% + 3)
60V0.01V
600V0.1V±(0.8% + 5)

 

- Min/ input voltage:0.5VV DC

- Input impedance:10MW

- Maximum/ input voltage:600V AC (Effective value)OR 600V DC

 

3.2.4 AC voltage 

 

RangeResolutionAccuracy
6V0.001V

 

±(1.0% + 5)

60V0.01V
600V0.1V±(1.2% + 5)

- Min/ input voltage:1.0V DC

- Input impedance:10MW

- Maximum/ input voltage:600V AC (Effective value)or 600V DC

- Frequency range:45Hz ~65Hz

 

 

3.2.5 Frequency 

 

3.2.5.1 Through the V file:

 

RangeResolutionAccuracy
60.0Hz0.1Hz±(1.0% + 5)
1000Hz1Hz

 

- Range:40Hz ~ 1000Hz

- Input range:≥ 0.2A AC(Effective value)

 

3.2.5.2 Through A File (From Clamp)

 

RangeResolutionAccuracy
60.0Hz0.1Hz±(1.0% + 5)
1000Hz1Hz

- Range:40Hz ~ 1000Hz

- Input range:≥ 1.0V AC(Effective value)

 

3.2.6 Resistance

 

RangeResolutionAccuracy
6kW0.001kW±(0.8% + 3)
60kW0.01kW
600kW0.1kW
6MW0.001MW±(1.2% + 3)
10MW0.1MW

 

- Overload protection: 600V DC or AC(Effective value)

 

 

Current measurement

 

1) Hold the trigger, open the pliers, and clamp a wire of the circuit under test in the pliers.
2) When the measured signal is greater than or equal to 0.02A, the main screen of the instrument will display the measured current value, and the secondary screen will display the frequency value of the current (note: the meter will only display the frequency value if the current is greater than or equal to 0.02A)

 

Noted


1) The correct measurement results cannot be obtained by clamping two or more wires of the circuit under test at the same time.
2) In order to obtain accurate readings, the conductor under test should be placed as far as possible in the center of the current clamp.
3)  Represents the maximum input ac current of 400 A.
4) Please hold the clamp head when the current measurement machine to open the clamp head and nose pliers head clip conductor under test, and then slowly let go of the trigger, until the clamp head closed completely, please be sure to test whether the conductor is picking up in the middle of the tong head, not in the tong head center will produce additional error, clamp table can only measure electrical conductor, a conductor if two or more current is measured at the same time, the measuring reading will be wrong.

Hot Products

Anti Shock Digital Smart Multimeter Auto Ranging 9.999nF 99.99nF Description: 1.1.1 When using the ...
Manual Range 1000V Digital Smart Multimeter Sine Wave Signal RMS Measurement Manual Range 60Hz ...
LCD display True Rms Digital Smart Multimeter Anti High Voltage Circuit Description: True RMS The ...
LCD Digital multimeter DC AC Voltage Diode Freguence multimeter Volt Tester Test Current Follow the ...
Lightweight 600V DC Auto Ranging Digital Multimeter 9999 Counts Display Technical indicators Ambient ...
1000V DC 0.01V 600V AC 19999 Counts Electrical Digital Multimeter True RMS Voltage Meter Technical ...