IEC 61851-1 Impulse Voltages Generator For Over-Voltages Test

 

Product information:

 

The impulse test generator conforms to the standard requirements of IEC 61851-1 clause 12.7, IEC 61851-23 clause 11.4, etc.

 

Technical parameters:

 

Model

SN1104

SN1104A (Optional)

DC high voltage

Max. 12.5kV

6kV

Impulse voltage wave

Impulse wavefront time: 1.2 µs ± 30 %;

Half value of after wave time: 50 µs ± 20 %

Please note that the waveform should be checked on an external oscilloscope

Impulse wavefront time: 10 µs ± 30 %;

Half value of after wave time: 700 µs ± 20 %

Please note that the waveform should be checked on an external oscilloscope

Instrument internal resistance

12Ω± 10%and 500Ω± 10%

40Ω±10%

Peak voltage: 300 V~ 12,500V

300-12500V, Low: 300 V~ 2,500V;

High: 2,500 V~ 12,500V

0~6kV, ± 5%

Impact interval time

5 ~ 99s

30~999s

Impact cycles

1 ~ 9999

Polarity

Positive and negative

Working power sourceRated voltage: ~ 220V±10%, 50Hz, Power consumption: 50 VA
Dimension430mm×180mm×480mm
Weight20 KG
 

Application:

 

It is used to verify that the appliances shall withstand the transient over-voltages to which they may be subjected. The impulse voltage test is a destructive test in which a breakdown occurs if the test specimen cannot withstand the applied voltage. When the sample breaks down, sparks and discharge sounds will be generated. The peak voltage of the instrument will drop significantly (close to zero) when it is no-load. When the same voltage is applied again, the above phenomenon will occur.

 

 

Hot Products

IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...
Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
IEC 62552 Refrigerator Freezer Energy Efficiency Lab Overview: This refrigerator performance lab is ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...
5RT Air Enthalpy Laboratory Air Conditioner Energy Efficiency Performance Lab System overview This ...