Home Companies Sinuo Testing Equipment Co. , Limited

IEC 62133-1 Battery Vibration Impact Test Bench With Real Time Display Function

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 62133-1 Battery Vibration Impact Test Bench With Real Time Display Function

Country/Region china
City & Province guangzhou guangdong
Categories Used Measuring & Analysing Instruments
InquireNow

Product Details

 

IEC 62133-1​ Battery Vibration Impact Test Bench With Real-Time Display Function

 

Overview:

 

This vibration system conforms to IEC 60068-2-6, it is required by IEC 62133-1:2017 clause 7.2.2, IEC 62133-2:2017 clause 7.3.8.1,etc.

 

Technical Parameters:

 

Vibration generator
Sinusoidal thrust2940N (300kg.f)
Random thrust2940N (300kg.f)
Impact thrust5880N(600kg.f)
Frequency rangeDG~3500Hz
Continuous displacement20mm
Impact displacement (maximum displacement)25mm
Maximum speed1.8m/s
Maximum acceleration981m/s2 (100g) (No-load)
Dynamic diameterΦ150mm
First-order resonant frequency2900 Hz±5%
Allowable eccentric moment≤2500N·cm
Equivalent mass of moving parts3kg
Load connection point13
Table screw size (standard)M8
Table screw layout (diameter, Yuan Zhou)13-M8 Depth 16mm
Axial vibration isolation frequency<3Hz
Maximum load120kg
Magnetic flux leakage≤1mT
Ambient temperature0~40℃
Size1600mm×800mm×700mm
Weight1100kg
Power amplifier output3kVA
Signal-to-noise ratio>65dB
System protection
  1. Power amplifier overvoltage protection
  2. System timing protection
  3. Power amplifier undervoltage protection
  4. Zero Signal Protection (Reset)
  5. over displacement protection
  6. Leakage protection
  7. Table overheat protection
  8. Excitation fuse protection
  9. Module overheat protection
  10. External timing protection
  11. Output overcurrent protection
  12. External zero signal protection
  13. Output overvoltage protection
  14. Water Smoothing Platform Interlocking Protection
  15. Module over-current protection
  16. Thermal overload protection
  17. Module timing protection
  18. Power amplifier boot soft start protection
Rated output voltage100Vrms
Output currentWith the 150A step, the maximum can be up to 6000A
Input impedance≥15kΩ
Input signal voltage≤1.5Rms
Efficiency of power amplifier>92%
Harmonic distortion (resistance load)<1.0%
Output voltage measurement error≤5%
Output current measurement error≤5%
Output current crest factor≥3
DC stabilityZero drift at the output is less than 30mv/8h
Frequency range1-3500Hz:±3dB ; Medium frequency gain:≥80
DC/AC conversion efficiency>92%
Load propertyResistive, capacitive, emotionally arbitrary
Unbalance of parallel flow≤2.8%
Average time free working time(MTBF)>3500 hours
Cooling modeForced air cooling
PowerAC 3phase 380V±10%, 60Hz
Size600mm×620mm×1600mm
Weight580kg
Cooling fan with muffler
Fan power0.75kW
Air volume0.1m3/s
Duct diameter125mm
Duct length4m
wind pressure1kpa
Size500mm×520mm×650mm
Weight30kg
Horizontal extension slide
Platform size500×500mm
Equivalent mass (maximum load-bearing)28kg
Upper bound frequencySine 2000Hz, random 2000HZ
MaterialMagnesium aluminum alloy
Vertical Expansion Table
Platform size500mm×500mm
Equivalent mass (maximum load-bearing)28kg
Upper bound frequencySine 1500Hz,random 2000HZ
MaterialMagnesium aluminum alloy
 
Controller overview and main technical parameters:

 

1.Sinusoidal Control Measurement System Specifications and Functions:

 

Frequency range2-5000Hz
Crossing point32 segments, and can wait for displacement, equal speed, etc.
Frequency displayThe vibration test curve set by the man-machine dialogue can be directly displayed on the screen. In the vibration test, the vibration curve can be displayed in real time, and the error dB at the time can be displayed continuously.
Output voltage7Vrms
Sweep modeLinear, logarithmic
Sweep rate0.1-10oct/min
Control accuracy±0.5dB
Dynamic Range79dB
Control methodPeak, average, rms, tracking filter
Vibration ModeConstant Frequency, Sweep (Linear, Logarithmic), Pause, Resume, Return
Filter formBiased anti-aliasing filter (eight-stage) passband 0.2dB/oct
Signal formSine wave
Waveform distortion≤0.5%

Setup function: The test specification of the human-machine dialogue setup can be saved for reuse

The controller can be on the rack, integrated with the amplifier cabinet, and can also be separated from the amplifier cabinet

 

2. Random Control Measurement System Specifications and Functions:

 

Frequency range100,200,400,500,1000,2000,4000,5000Hz
Resolution100,200,400,800 lines
Driving spectrum dynamic range60dB
Control spectrum dynamic range40dB
Loop time2000Hz, 400 lines single channel 0.6 seconds
Power spectrum control accuracy±1dB (90% confidence)
RMS value control accuracy±0.2dB
Control ChannelsIndependent Channels
Control methodAverage, maximum
Spectral settingsUp to 32 levels, both with PSD [(m.s2)2/Hz] and dB/oct settings

 

3.Impact control measurement system technology standard and function:

 

WaveformHalf Sine, Triangle, Sawtooth, Square Wave
Frequency Range5-2000Hz
Vibration level presets-18dB, -15dB, -12dB,-9dB,-6dB,-3dB,0dB seven vibration levels, vibration time for each vibration level :Set by the user.
Upgrade ModesAutomatic upgrade and manual upgrade
Display functionWith real-time display, print function.
Protection functionOver-limit alarm, open-circuit protection and automatic over-limit shutdown
Setting functionThe test specification set during the man-machine conversation can be saved for repeated use.
Measuring range0-200g divided into eight gears 1,2.5,5,10,25,50,100,200g range automatically shift
Filter FormatProgrammable anti-aliasing filter (eight-stage) 0.2dB pass band and -55dB/oct stop band
Signal formTrue random, pseudo-random

 

4. Characteristics and Technical Specifications of USB01 Card:

 

Full-scale input16-bit 16-channel single-ended A/D, speed 400KS/S, +/-5V
Full-scale outputOne 16-bit D/A, +/-5V
Win-XPSupports USB1.1 and USB2.0 standards for Win-2000
Main Controller32-bit 120MHz Floating Point Digital Signal Processor (DSP)
Digital output8 bits
High-speed continuous acquisition34K*32Bit high-speed static memory
Clock signal output819.2K filter
Input Channel16-channel single-ended
Analog Input Signal Voltage RangeBipolar +/-5V
Resolution16 bits
A/D conversion time2.5 microseconds
Acquisition pass rate400KHz
AccuracyBetter than 0.015%
Nonlinear deviation<4 LSB
Data Format16-bit twos complement
Input impedance10 MΩ
A/D conversion trigger modeInstruction, timer
D/A output signal voltage rangeBipolar +/-5V
D/A resolution16 bits
Digital/analog conversion time5 microseconds
Accuracybetter than 0.015%
Nonlinear deviation<4 LSB
Data Format16-bit twos complement
Output impedance<0.1Ω
Main controller32-bit 120MHz floating point DSP TMS320VC33
System clock40.96KHz
Two 32-bit timer/countersFor D/A and A/D timing
Digital output8 bits(TTL)
Clock output819.2KHz
Power Consumption<2.5W(5V, 500mA)
 

 

Hot Products

IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...
Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
IEC 62552 Refrigerator Freezer Energy Efficiency Lab Overview: This refrigerator performance lab is ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...
5RT Air Enthalpy Laboratory Air Conditioner Energy Efficiency Performance Lab System overview This ...