Home Companies Sinuo Testing Equipment Co. , Limited

3500Hz Battery Vibration Impact Test Bench With Print Function

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

3500Hz Battery Vibration Impact Test Bench With Print Function

Country/Region china
City & Province guangzhou guangdong
Categories Optical Instruments
InquireNow

Product Details

 

IEC 62133-1 Battery Vibration Impact Test Bench With Print Function

 

Overview:

 

This vibration system conforms to IEC 60068-2-6, it is required by IEC 62133-1:2017 clause 7.2.2, IEC 62133-2:2017 clause 7.3.8.1,etc.

 

Technical Parameters:

 

Vibration generator
Sinusoidal thrust2940N (300kg.f)
Random thrust2940N (300kg.f)
Impact thrust5880N(600kg.f)
Frequency rangeDG~3500Hz
Continuous displacement20mm
Impact displacement (maximum displacement)25mm
Maximum speed1.8m/s
Maximum acceleration981m/s2 (100g) (No-load)
Dynamic diameterΦ150mm
First-order resonant frequency2900 Hz±5%
Allowable eccentric moment≤2500N·cm
Equivalent mass of moving parts3kg
Load connection point13
Table screw size (standard)M8
Table screw layout (diameter, Yuan Zhou)13-M8 Depth 16mm
Axial vibration isolation frequency<3Hz
Maximum load120kg
Magnetic flux leakage≤1mT
Ambient temperature0~40℃
Size1600mm×800mm×700mm
Weight1100kg
Power amplifier output3kVA
Signal-to-noise ratio>65dB
System protection
  1. Power amplifier overvoltage protection
  2. System timing protection
  3. Power amplifier undervoltage protection
  4. Zero Signal Protection (Reset)
  5. over displacement protection
  6. Leakage protection
  7. Table overheat protection
  8. Excitation fuse protection
  9. Module overheat protection
  10. External timing protection
  11. Output overcurrent protection
  12. External zero signal protection
  13. Output overvoltage protection
  14. Water Smoothing Platform Interlocking Protection
  15. Module over-current protection
  16. Thermal overload protection
  17. Module timing protection
  18. Power amplifier boot soft start protection
Rated output voltage100Vrms
Output currentWith the 150A step, the maximum can be up to 6000A
Input impedance≥15kΩ
Input signal voltage≤1.5Rms
Efficiency of power amplifier>92%
Harmonic distortion (resistance load)<1.0%
Output voltage measurement error≤5%
Output current measurement error≤5%
Output current crest factor≥3
DC stabilityZero drift at the output is less than 30mv/8h
Frequency range1-3500Hz:±3dB ; Medium frequency gain:≥80
DC/AC conversion efficiency>92%
Load propertyResistive, capacitive, emotionally arbitrary
Unbalance of parallel flow≤2.8%
Average time free working time(MTBF)>3500 hours
Cooling modeForced air cooling
PowerAC 3phase 380V±10%, 60Hz
Size600mm×620mm×1600mm
Weight580kg
Cooling fan with muffler
Fan power0.75kW
Air volume0.1m3/s
Duct diameter125mm
Duct length4m
wind pressure1kpa
Size500mm×520mm×650mm
Weight30kg
Horizontal extension slide
Platform size500×500mm
Equivalent mass (maximum load-bearing)28kg
Upper bound frequencySine 2000Hz, random 2000HZ
MaterialMagnesium aluminum alloy
Vertical Expansion Table
Platform size500mm×500mm
Equivalent mass (maximum load-bearing)28kg
Upper bound frequencySine 1500Hz,random 2000HZ
MaterialMagnesium aluminum alloy
 

Digital Switch Power Amplifier Overview:

 

1. Users can check the working status of each module and system at any time. If a power module fails, it can be removed manually.

2. With power factor compensation device, the power factor of the whole power amplifier is up to 92%, so that the power grid capacity can be fully utilized.

3. Using sinusoidal frequency double pulse width modulation technology, the power amplifier has a high signal-to-noise ratio.

4. Using the working principle of switching power supply, the conversion efficiency is high, and the conversion efficiency of the power module can reach 92%. The entire power amplifier system is completely forced air-cooled.

5. Using electronic automatic current-sharing technology, the parallel connection of each module is almost the same, and the parallel unbalanced current sharing ratio is ≤2%.

6. The power device adopts imported field effect modules (other domestic manufacturers generally use field effect single-tube). The protection circuit is reduced, the reliability is improved, the current capacity is large, and the maximum output of a single power module box is 25 kVA.

7. The power module box is small in size, with 5kVA, 10kVA, 15kVA, 20kVA, etc., which can be selected according to the user's actual situation.

8. Complete protection function, the entire power amplifier has 18 protection functions

 

Vertical Expansion Table:

 

In the actual vibration test, the tested product is often larger than the electric table top. At this time, it is necessary to expand the original table top. A common method is to install an auxiliary table. Some tested products require special installations. This requires a custom fixture to meet this installation. Both of the above conditions must meet certain technical specifications, such as working frequency, table weight, table acceleration, amplitude uniformity and laterality, etc. Therefore, there are strict requirements for such tables or fixtures. The TB expansion table and special fixtures have been carefully calculated and carefully designed to ensure the user obtains the optimal performance from the structure, materials, and manufacturing processes.

 

Horizontal extension slide:

 

It has a high tipping moment and lateral limitation. At the same time to maintain the steering oil film damping characteristics. The water smoothing platform is composed of a skateboard, a connector, a natural granite plate, and a horizontal slide base.

The high-pressure oil becomes a low-pressure oil through the damper, forming a layer of oil film between the bottom surface of the slide table and the granite plate. The oil film mainly plays the role of lubrication and reduces the friction generated when the sliding table mesa moves on the granite plate. Make the horizontal slide table free to move on the granite slab. The high-pressure oil source and the horizontal slide are connected together by the high-pressure oil pipe, so that the horizontal slide system has a simple structure, convenient operation and maintenance, and reliable operation.

 

 

Hot Products

IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...
Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
IEC 62552 Refrigerator Freezer Energy Efficiency Lab Overview: This refrigerator performance lab is ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...
5RT Air Enthalpy Laboratory Air Conditioner Energy Efficiency Performance Lab System overview This ...