Home Companies Sinuo Testing Equipment Co. , Limited

IEC 60335-2-6 Stationary Ovens 4.5kg Load For Testing Rotating Spits

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 60335-2-6 Stationary Ovens 4.5kg Load For Testing Rotating Spits

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

 

IEC 60335-2-6 Stationary Ovens 4.5kg Load For Testing Rotating Spits

 

Product overview:

IEC 60335-2-9 clause 3.1.9.102 Figure102, Household and similar electrical appliances -Safety-Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances

IEC60335-2-6 clause 3.1.9.104 Figure 103, Household and similar electrical appliances-Safety- Part 2-6: Particular requirements for stationary cooking ranges, hobs, ovens and similar appliances

The equivalent mass is about 4. 5kg.

It is made of stainless steel.

Size: Ф100+20 mm * 85+10 mm.

 

Technical Characteristics:

 

Applied Standards & ClausesIEC 60335-2-9 clause 3.1.9.102 Figure102
IEC60335-2-6 clause 3.1.9.104 Figure 103
Load DiameterФ100+20 mm
Load Thickness85+10 mm
Load MaterialStainless steel
Load Equivalent Mass4.5 kg
 

 

Test procedures and operation

Take IEC 60335-2-6:2018 clause 3.1.9.103:

Rotating spits in ovens or grills are operated with the load on the rotating spit as shown in Figure 103. The appliance is operated taking into account the instructions with regard to

-the heating elements to be operated;

-the setting of the thermal control;

-the position of t he door and grill pan.

 

In the absence of such insstructions, the contril is adjusted to its highest setting and the door is fully open or is placed in the most unfavourable intermediate position in which it may be left.

 

Any grill pan is placed in its lowest position.

 

Notice

1. Please do not damage the appliance shape (such as scratching, bending, etc.).

2. Prevented from dust and moisture environment, in order to avoid the oxidation to affect the dimensional accuracy.

 

 

IEC 60335-2-9 clause 3.1.9.102 Figure102

 

Hot Products

IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...
Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
IEC 61591 Air Performance Test System for Cooking Fume Extractors Technical parameters: 1. ...
IEC 62552 Refrigerator Freezer Energy Efficiency Lab Overview: This refrigerator performance lab is ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...