IEC 61439 Low-Voltage Switchgear And Controlgear Assemblies Static Load Test Bench

 

Standards & Clauses:

IEC 61439-5:2014 Low-voltage switchgear and controlgear assemblies - Part 5: Assemblies for power distribution in public networks

IEC 61587-1:2007 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation

IEC 62208:2011 Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements

IEC 62271-202:2014 High-voltage switchgear and controlgear - Part 202: High-voltage/ low-voltage prefabricated substation

 

Technical Parameters:

1Loading directionHorizontal 2, vertical 1
2Movable range3 to 8 degrees of freedom
3Loading wayelectric
4Scope of application of a force0-20KN
5Applying speed0.1-50 mm/s
6The power supply220V/50Hz
 
 

Product Overview

Static load test bench is mainly used for mechanical loading test and related scientific research test of low-voltage meter box, pre-installed substation, electrical equipment shell. It is convenient for mechanical performance test of metal meter box, non-metal meter box, cable branch box and other multi-specification meter box.

The machine adopts frame structure, which is divided into horizontal loading part and vertical loading part. Each loading actuator can move freely in the plane with 3 degrees of freedom. A total of 8 dof mobile loading was achieved by three actuators.

Practical structure: the device adopts the whole frame structure, firm and reliable.

 

Hot Products

IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...
Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
IEC 61591 Air Performance Test System for Cooking Fume Extractors Technical parameters: 1. ...
IEC 62552 Refrigerator Freezer Energy Efficiency Lab Overview: This refrigerator performance lab is ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...