Home Companies Sinuo Testing Equipment Co. , Limited

IEC 60695-2-2 Needle Flame Flammability Test Chamber Touch Screen

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 60695-2-2 Needle Flame Flammability Test Chamber Touch Screen

Country/Region china
City & Province guangzhou guangdong
Categories Solar Chargers
InquireNow

Product Details

 

IEC 60695-2-2 Needle Flame Flammability Test Chamber PLC Control

 

 

Test principle:


Needle flame tester is a needle burner with a specified size (φ 0.9mm), with specific gas (butane), with 45° Angle timing and directional burning test, depending on whether the test is ignited and holding the combustion time and combustion length to assess the fire risk of small flame caused by fault conditions inside the equipment.

 

Equipment advantages:


The device can give a quick and accurate warning: the time from 100°±5°C to 700°±3°C is 23.5s ±1s. When combustible occurs within the equipment due to failure conditions, the fire hazard of the equipment is assessed by the time and length of time the sample can be ignited or burned.
Needle flame test box is equipped with advanced PLC control, 7 "color touch screen, easy to operate.

Mainly used in lighting equipment, low-voltage electrical appliances, household electrical appliances, machine tools, and other components of the research, production and quality testing departments. Also suitable for insulating materials, engineering plastics or motor, power tools, electronic instruments, electrical instruments, electrical connectors, electrical and electronic equipment and other solid burning materials industry.

 

 

Technical parameters:

 

Parameter/ modelSN773B (PLC + touch screen version)
Working voltageMatch client's local power supply requirements
ControlAdvanced PLC
Display7 inch color touch screen
Timing device9999X0.1S
CombustorInner boreφ0.5mm ± 0.1mm, OD ≤φ0.9mm, L ≥ 35mm, stainless steel
Combustion angletilt 45° (testing) or vertical (when adjust the height of the flame)
Height of the flame12±1mm adjustable (with flame height gauge)
Gas category95% Butane (should be prepared by user)
Range of temperature test0~1000℃
Flame warming requirementFrom 100°to 700°, time for standard values within 23.5S±1S
Temperature thermocoupleφ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple
Work shop0.5 cube, stainless steel case, dark background
Testing processTest procedure automatic control, independent air draft
Volume size adjustmentFlowmeter adjustment
Equipment size & weight1100mm* 550mm* 1100mm, 120KGS
Conforms to standardIEC 60695-11-5, IEC60335-1, etc.
 
 

Hot Products

IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...
Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
IEC 61591 Air Performance Test System for Cooking Fume Extractors Technical parameters: 1. ...
IEC 62552 Refrigerator Freezer Energy Efficiency Lab Overview: This refrigerator performance lab is ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...