Home Companies Sinuo Testing Equipment Co. , Limited

New Energy Vehicles Particular Safety Test System For Whole Vehicle

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

New Energy Vehicles Particular Safety Test System For Whole Vehicle

Country/Region china
City & Province guangzhou guangdong
Categories Polishers
InquireNow

Product Details

 

New Energy Vehicles Particular Safety Test System for Whole Vehicle

 
System features:
1. Meet the requirements of automotive-related national and international standards: such as GB/T 18384, GB/T 18487, GB/T 20234, etc.
2. Multi-function in one: AC and DC withstand voltage, charging socket insulation, whole vehicle insulation, insulation resistance monitoring, leakage current, potential equalization, fast charging function, slow charging function.
3. High test accuracy: the basic accuracy of safety testing is 1.5%, and the measurement accuracy of electrical parameters is 0.5%.
4. Record the vehicle VIN number, VSN number and main part number, and print a test result for each vehicle.
5. Bar code recognition, automatic matching, automation, and intelligent testing.
6. Data storage, query and screening, information management.
7. Perfect protection: if the plug is not plugged in, the device will not start high voltage detection; pulling out the plug in the detection state will cut off the power supply to the socket.
8. It can be extended to connect with MES system.

9. 19" LCD display
10. Support customization.

 
Technical Parameters:

Potential Equalization
Test channel10 channels
Test method/No-load output voltageFour-wire system
Output current setting rangeDC:1.00~32.00A
Output current accuracy± (1% of setting+0.20A)
Grounding resistance setting rangeUpper limit: 0~600mΩ; lower limit: 0~600mΩ; 0=off
Grounding resistance measuring range0.0~600mΩ
Grounding resistance measuring accuracy± (1% of reading+3mΩ)
Test time setting range0.0, 0.1~999.9s 0.0=Continuous output
Test time setting range accuracy± (1% of setting+0.05s)
Charging Socket Insulation
Output voltage rippleResistive load, 1000V/1mA, <5%
Output voltage setting range/accuracyDC:100~1000V ccontinuous adjustable
± (1% of setting+3V)
Insulation resistance setting rangeUpper limit: 0,1~3000MΩ; lower limit: 1~3000MΩ; 0=off
Resistance compensation>30MΩ
Insulation resistance measuring range0.05~99.99~999.9~3000MΩ
Insulation resistance measuring accuracy100~499V:0.1 ~2000MΩ:± (5% of reading+2MΩ)
 500~1000V:0.2 ~1000MΩ:± (2% of reading+2digitals)
 1000 MΩ~3000 MΩ:± (5% of reading+2digitals)
Delay time setting range0.5~999.9s
Test time setting range0.0, 0.1~999.9s, 0.0= Continuous output
Test time setting accuracy± (1% of setting+0.05s)
Whole Vehicle Insulation Test
Insulation resistance setting range

Upper limit 0,0.00-100.0MΩ 0=close,

lower limit 0.00- 100 00MΩ

Insulation resistance measurement range0.20- 100.00MΩ
Insulation resistance measurement accuracy±(2% reading value + 2 words)
Test time setting range

0.0- 999.9S

0.0=continuous output

Test time setting accuracy±(0.1% setting value+0.05s)
Insulation Monitoring
Test time setting range

0.0- 999.9S

0.0=continuous output

Test time accuracy±(0.1% setting value+0.05s)
Judgment typeWhether the automotive insulation monitoring is normal and alarm
AC Withstand Voltage
Withstand voltage test typeCold withstand voltage test
Rated output load200VA (AC: 5000V/40mA )
Output voltage adjustment rate<2% (no load to full load)
Output voltage setting rangeAC:100-5000V ;50Hz/60Hz
Output voltage accuracy±(1% setting value+3V)
Breakdown current setting rangeUpper limit: 0.000-9.999- -40.00mA
Lower limit: 0.000-9.999- -40.00mA 0.000=close
Zero current0.000-2.000mA
Breakdown current measurement range0.050- 9.999-40.00mA
Breakdown current measurement accuracy±(1% of reading value + 5 words)
Rise time/slow down time0.0-999.9s
Test time setting range

0.0, 0.1-999.9S

0,0=continuous output

Test time setting accuracy±(0.1% setting value+0.05s)
DC Withstand Voltage
Withstand voltage test typeCold withstand voltage test
Rated output load60VA (DC: 6000V/10mA )
Output voltage adjustment rate<2% (no load to full load)
Output voltage setting rangeDC:100-6000V
Output voltage accuracy±(1% setting value+3V)
Breakdown current setting range

Upper limit: 0.000-9.999-10.00mA;

Lower limit: 0.000-9.999-10.00mA 0.000=off

Zero current0.000- -2 000mA
Breakdown current measurement range0.020-9.999-10.00mA
Breakdown current measurement accuracy±(1% of reading value+0.005mA)
Rise time/slow down time0.0-999.9s
Test time setting range

0.0, 0.1-999.9S

0.0=continuous output

Test time setting accuracy±(0.1% setting value+0.05s)
Leakage Current
Leak type settingStatic
Output voltage ratio

1.1 times input voltage (output by isolation transformer)/arbitrarily set voltage (output by variable frequency power supply)

 

Output voltage setting rangeAC:0.0-3000V
Output voltage setting measuring rangeAC:5.0-300.0V
Output voltage measurement accuracy±(1% of reading value+3V)
Leakage current setting range

Upper limit: 0.000-5.000mA; Lower limit: 0.000-5.000mA

0.000=off

Zero current0.000-2.000mA
Leakage current measurement range0.050-9.999 - 20.00mA
Leakage current measurement accuracy± (1% of reading value + 5 digits)
Test time setting range

0.0, 0.5-999.9S

0.0=continuous output

Test time setting accuracy(0.1% setting value+0.05s)
Slow Charging Function Detection (Customization)
Voltage setting rangeAC:0.0-300.0V
Charging current measurement range0.050-9,999-32.00A
Test time setting range

0-999.9S

0.0=continuous output

Fast Charging Function Detection (Customization)
Charging voltage measurement rangeDC;0.0-700.0V
Charging current measurement range0.050-9,999-63.00A
Test time setting range

0.0-999.9S

0.0=continuous output

 
 
 

Hot Products

IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...
Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
IEC 61591 Air Performance Test System for Cooking Fume Extractors Technical parameters: 1. ...
IEC 62552 Refrigerator Freezer Energy Efficiency Lab Overview: This refrigerator performance lab is ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...