ISO 105 SAE JI885 High Quality Xenon Lamp Aging Environmental Test Chamber

 

Product Description:
The Xenon lamp aging test chamber uses imported 6500W long-arc water-cooled xenon lamp as the light source. it simulates the comprehensive conditions of light, heat and rainfall of the outdoor climate by changing and controlling the light irradiance, temperature (sample holder temperature, working room temperature), relative humidity, spray method, etc., then artificial aging tests are performed on the samples. This equipment complies with multiple test methods such as GB, ISO, ASTM, etc., and is suitable for laboratory light source exposure tests for various materials and products such as coatings, plastics, rubber, chemical building materials, and auto parts.

 

Technical Parameters:

Dimensions124cm×114cm×202cm (W×D×H)
Exposure area6500cm2/ About 65 standard samples (140mm×70mm)
Light source6.5kW long arc water-cooled xenon lamp (imported from the United States Q-LAB)
Light source lifeAbout 2000h (based on irradiance 0.51W/m2 @340nm)
Irradiance display band340nm,420nm,300~400nm optional
Irradiance range

0.3W/m2~1.1 W/m2(@340nm)

40 W/m2~120 W/m2(@300nm~400nm)

Sample temperature

Blackboard temperature: 40℃~110℃

Black mark temperature:40℃~120℃

Temperature in the chamber38℃~80℃
Humidity in the chamber

When illuminated: 30%RH~75%RH (related to temperature)

In the dark: up to 100%RH

Test Conditions

Free combination of light, darkness and water spray

Supported test standards

Conforms to SAE J2412, SAE J2527, ASTMG 155, ISO 105-B02, ISO 105-B04, ISO 105-B06, ISO 4892-2-A, SO 11341-1, GB/T 16422-2,GB/T 1865, etc.

With 4 custom methods, users can set test parameters by themselves to meet most common standard requirements.

 

Equipment Features:

  1. PLC controller of American GE company, automatic control, safe and reliable operation
  2. With touch screen man-machine interface, the operation is simple and powerful
  3. c) Real-time display and automatic control of sample rack temperature (BST, BPT), working room temperature (DB), relative humidity, light irradiance energy, test time
  4. Equipment status and equipment failure monitoring
  5. With 16 programs of defaut setting as per different standards and 4 custom programs which can be defined by operator
  6. Come with pure water treatment machine and chiller, which ensure the water supply quality for testing is high
  7. It is with imported Q-LAB water-cooled xenon-arc lamp, spectral irradiance 0.3W/m2~1.1 W/m2 (@340nm), together with other imported high quality components, the chamber’s quality is much higher than other versions of xenon weathering test chambers in the markets.

Comparisons between our Xenon Ageing Test Chamber with others in the markets:

 SN883-X65OthersComparison results
Cooling systemWater cooling systemMainly air cooling systemSN883-X65 can reach a higher power level to meet the needs of current and future test development. There is cooling water flowing between the filters, which can effectively reduce the infrared heat to the sample surface. And reduce the generation of ozone, increase the accurate matching with the external environment.
Cooling effect: water cooling is better than air cooling.
Lighting sourceOrignial 6500W xenon lamp tube imported from the United States
Brand: Q-LAB
Domestic lamps (mostly produced by Shanghai Aojia)Imported lamp tube: (spectral energy distribution) curve shape is stable, and it has been specially tested before leaving the factory. Water-cooled full-spectrum xenon arc lamp, chemical analysis grade xenon lamp SPD spectral energy part of the whole life almost unchanged
Other domestic equipment generally uses Shanghai Aojia lamp and power supply integration, and there is uncertainty in lamp life and spectrum.
Irradiation intensity range0.3 W/m2~1.1 W/m2(@340nm)
40 W/m2~120 W/m2(@300nm~400nm)
Use long wave and for example 550w/m2 to expressSN883-X65 can reach 2 of levels which close to the sun level . Other domestic equipment is generally customized based on a certain standard and does not understand the irradiance requirements of different fields.
Sample area6500cm2 (65 standard samples: 14*7cm)Express according to cabinet specificationsRemark: SN883-X65 is based on the American ATLAS CI4000, including the parameter specifications, the expression method is based on the exposure area. Other domestic products generally follow the expression method of temperature chamber.
Lamp life2000-3000 hours500-800 hoursDomestic lamps are easier to attenuate in terms of irradiance and have a shorter life span.
Way to control340nm, 420nm or 300-400nm can be switchedGenerally use long wave band controlOther domestic xenon lamps are generally based on a certain standard, such as IEC65-2-5 or GB/T2324 will be expressed in 1120W/m2 or 550W/m2
Blackboard temperature
Black mark temperature
BPT40~110℃
BPT40~120℃
Generally there is only one control methodSN883-X65 can independently control the temperature of the blackboard/black mark and the temperature in the box. The switch of BST/BPT can be selected on the control screen. There is no need to replace any sensors, which greatly simplifies the operation. Automatically identify and select control according to standard requirements. The thermometer rotates at the same position as the sample, which truly represents the surface temperature of the sample.

Other domestically produced thermometers can only be installed with one thermometer, which can be replaced manually. The thermometer is fixed in one position of the cabinet, which may not be on the sample rack.
Humidity rangeLight cycle: 10-75%,
Dark cycle: up to 100%
Light cycle: 10-75%,
Dark cycle: reach 100%
Other domestically produced refrigeration compressors are used to control the temperature of the cabinet, which is better than SN883-X65, but the process of constant temperature and humidity cabinet is used, and the probe is generally exposed to the lamp, which cannot strictly meet the standard requirements. (The temperature and humidity probe of SN883-X65 adopts electronic rather than wet and dry bulb form, located at the top of the device)
Calibration toolSelf-developed calibratorNone or outsourcingThe calibrator is a necessary tool for evaluating equipment stability. SN883-X65's calibrator can compare and exchange data with imported equipment. Ensure that the reliability of the test data is maintained during the lamp decay process.
Filter combinationU.S. imported internal and external filtration system
A variety of options (including daylight window glass, etc.)
Generally only daylight (domestic glass)SN883-X65 choose the original filter set combination imported from the United States, which can be interchanged with imports. Other domestic products are generally based on the GB/2324 electronic standard, and they only know daylight filtering, and they have not analyzed the cost requirements of the filter cover.
Control System7-inch touch screen control panel displays all test parametersGenerally, domestically produced programs are adopted, and the temperature chamber control mode is usedSN883-X65:The control system can handle custom tests and process pre-programmed tests; the information set and displayed on the control system screen includes: blackboard temperature/black mark temperature, test box temperature, relative humidity, and irradiation intensity.
The system has corresponding predefined test methods. The test method list includes: national standard, SAE, ISO, ASTM, etc. The operator can copy and edit existing test methods (14 factory preset test methods) or custom tests (can be stored) 12 custom programs);

Other domestic products: no relevant standard switching content
Spray SystemProvide a consistent deionized water spray for the sample, and can achieve back sprayUsing ordinary pure water, only the front spray functionSN883-X65 has a spray system that can be sprayed on both sides, and the surface of the sample will gradually become dry during the rotation process. Each revolution is equivalent to a rain shower outdoors, accelerating the simulation of outdoor rainfall.

Other domestic products generally do not understand the standard requirements.

 
Test standardsMeet most of the standard requirements (including national standards, international standards)Meet a small number of national standardsSN883-X65 can meet more standard requirements
Inner DimensionW:124 cm
D:114 cm
H:202 cm(Including top inlet and exhaust ports)
Ordinary dimensionsSN883-X65 has large working volume

 


Hot Products

IEC60456 Water Supply System For Washing Machine Performance Test System overview The test system is ...
Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
60K BTU Double Code Air-Enthalpy Method Calorimeter ISO 5151 System introduction: This air enthalpy ...
30K BTU Single Code Test Laboratory Air Enthalpy Method Calorimeter System overview This air ...
IEC 61591 Air Performance Test System for Cooking Fume Extractors Technical parameters: 1. ...