Comprehensive Electrical Appliance Testing Equipment AC Hipot Insulation Ground Resistance Leakage Test

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

 

Electrical Safety Comprehensive AC Hipot Test Equipment , Hipot Insulation Tester

 

 

Standards & Clauses:

 

IEC60884-1:2013 “Plugs and socket-outlets for household and similar purposes- Part1: General requirements”

IEC60335-1:2016 “Household and similar electrical appliances-Safety-Part1: General requirements”

IEC60950-1:2013 “Information technology equipment-Safety-Part1: General requirements”

IEC60065:2014 “Audio, video and similar electronic apparatus-Safety requirements”

 

Samples and Restrictions:

 

Household appliances, electrical accessories, lamps, etc.

 

Application:

 

Various types of home appliance manufacturers, as well as institutions that conduct home appliance safety testing and certification, research institutes

 

Test Contents:

 

AC Hipot test, insulation resistance test, ground resistance test, leakage current test, run power and low voltage start performance test

 

Structure:

 

Floor-standing

Technical Parameters:

 

AC Hipot test
Booster rated output capacity500VA (5000V/100mA), short circuit current is greater than 200mA
Output voltage waveform, distortion, adjustment rateSine wave, <3% (pure resistance,5000V/1mA), <3% (from empty load to full load)
Output voltage settingRange500~5000V
Resolution, accuracy5V,±(3%×setting+10V)
Frequency settingRange, accuracy50Hz/60Hz, ±0.1%×setting
Alarming limits settingCurrent upper-limit0.10~99.99mA
Current lower-limit0.00~10.00mA
Compensation current settingRange0.00~10.00mA, automatic testing, compensation can be set to ON/OFF
Time settingRange1~999s
Ramp up time range1~100s
Accuracy±(0.1%×setting+1count)
Breakdown current alarmRange, accuracy0.10~99.99mA, ±(3%×reading+3counts)
Insulation Resistance test
Rated output capacity2VA(1000V/2mA)
Output voltage regulation, output voltage ripple
<3%(From no load to full load), <1%
Output voltage settingRange, accuracyDC 500V or 1000V, ±(3%×setting+3counts)
Alarming limits settingResistance upper-limit range0.0~99.9 MΩ,100~2000MΩ(If upper-limit is set to 0, it will not make adjudgment for upper limit)
Resistance lower-limit range0.3~99.9 MΩ, 100~2000MΩ
Time settingRange, accuracy1~999s, ±(0.1%×setting+1count)
Insulation resistance measurementRange0.0~99.9 MΩ, 100~2000 MΩ
Accuracy

≤200MΩ: ±(3%×reading+3counts)

>200MΩ:±(8%×reading+8counts)

Ground Bond Resistance test
No load output voltage<12V
Output current settingRange, accuracy3~30A, ±(3%×setting+0.2A)
Current frequency settingRange, accuracySine waveform 50Hz/60Hz, ±0.1%×setting
Test time settingRange1~999s
Accuracy±(0.1%×setting+1count)
Result display modeGround resistance or voltage
Ground resistance display mode
Alarming limits settingResistance upper-limit range

3A ≤ output current ≤ 10A:10~600 mΩ

11A ≤ output current ≤ 25A:10~300 mΩ

26A ≤ output current ≤ 30A:10~200 mΩ

Resistance lower-limit range0~100 mΩ
Compensation resistance settingRange0~200 mΩ, automatic testing, compensation can be set to ON/OFF
Ground bond resistance measurementRange, accuracy10~600 mΩ, ±(3%×reading+ 5counts)
Ground voltage display mode
Alarming limits settingVoltage upper-limit range30~7500 mV
Voltage lower-limit range0~3000 mV
Compensation voltage settingRange0~1000 mV, automatic testing, compensation can be set to ON/OFF
Ground bond resistance measurementRange, accuracy10~7500 mV, ±(3%×reading+ 50mV)
Leakage Current test
Leakage current test type settingSingle phase load, static/dynamic leakage current
MD network selectionStandard IEC 60990 figure 4 network; other test network optional
Alarming limits SettingCurrent upper-limit range0.050~9.999mA
Current lower-limit range0.000~5.000mA
Leakage current compensation settingRange0.000~1.000mA, automatic testing, compensation can be set to ON/OFF
Time test settingRange, accuracy1~999s, ±(0.1%×setting+1count)
Leakage current measurementRange0.050~9.999mA
Accuracy

DC~10kHz: ± (3%×reading+0.010mA)

10 kHz ~1MHz: ± (5%×reading+0.050mA)

Output voltage measurementRange, accuracy60~280V(phase voltage), ±(0.5%×reading+2counts)
Run Power Only forAN9651S(F)/AN9651F(F)/AN9651B(F)
Alarming limits settingPower upper-limit range6~6000W
Power lower-limit range0~6000W
Test time settingRange, accuracy1~999s, ±(0.1%×setting+1count)
Voltage measurementRange, accuracy60~280V (phase voltage), ±(0.5%×reading+2counts)
Current measurementRange, accuracy0.030~3.999A, 4.00~25.00A, ±(0.5%×reading+2counts)
Active power measurementRange, accuracy

30.0~199.9W: ±(0.5%×reading+5W),

200~6000W(or2000W): ±(0.5%×reading+30W)

Power factor measurementRange, accuracy0.10~1.00, ±(2%×reading+2 counts)
Low voltage start test
Alarming limits settingCurrent upper-limit range0.30~25.00A
Current lower-limit range0.00~25.00A
Test time settingRange, accuracy1~999s, ±(0.1%×setting +0.05s)
Voltage measurementRange, accuracy60~280V (phase voltage), ±(0.5%×reading+2counts)
Current measurementRange, accuracy0.030~3.999A, 4.00~25.00A, ±(0.5%×reading+2counts)
Power supply for UUT
SN2212B Built-in isolation transformer
Isolation transformer input voltage, frequencyDetermined based on input voltage and frequency
Isolation transformer output voltage ratioLeakage current testThe output voltage is 1.06 times the input voltage
Run power testThe output voltage is 1.00 times the input voltage
Low voltage start testThe output voltage is 0.85 times the input voltage
Isolation transformer capacitySingle phase load rated capacity 6000VA
Isolation transformer voltage regulation3% (from no load to full load)
Overcurrent protectionMaximum current is 30A, automatically cut off the isolated power supply after 5s overcurrent
SN2212S, SN2212F Built-in variable frequency power supply
Max. output capacity5000VA
Output voltage distortion1% @ 47~63Hz
Output voltage stability1%
Programmed output voltageVoltage range0~300V
Voltage accuracy0.5%RD+0.5%F.S.
Programmed output frequencyFrequency Range47~63Hz
Frequency stability0.1%
Output maximum current0~150V file27A
0~300V file14A
SN2212S Configured IN-Pad
ProcessorARM926 core, 400MHz frequency
Operating systemWindows CE
SoftwareESRS-Pad special software for safety test
Display10.4” TFT color LCD
Operation methodInput through touch screen, support input through USB interface mouse and keyboard
Storage50MB FLASH, user can choose large capacity SD memory card
External Interface2-way RS232 interface, 2-way USB interface, CAN interface, DC12V power interface
Mounting brackets3D, full angle, display stand
Bar code scannerOne barcode scanner with an RS232 interface defaulted
Interface function
Remote control interfaceStandard, standard foot switch (start)
Alarm light interfaceStandard, standard three-color warning light (test, qualified, warning)
Communication InterfaceStandard RSA32, optional RS485, network port, GPIB, etc.
Variable frequency power control interfaceOptional
Switch interfaceOptional, start, stop, test, pass, alarm switch output
Printer interfaceOptional, support for dot matrix printers and micro printers
General specification
Verification and calibration environment23 ° C ± 5 ° C, (45 ~ 75)% RH, less dust
Use environment0 ° C ± 40 ° C, (5 ~ 90)% RH, less dust
Storage environment-10 ° C ~ 55 ° C, (5 ~ 95)% RH, less dust
System power220V±10%, 50Hz±5%, 10A
System power consumptionMaximum 1000VA (excluding the operating power consumption of the tested product)
System weight (without packaging)About 80kg
Dimensions (mm, without packaging)SN2212S483(W)x 600(D)x 1355(H)
SN2212F483(W)x 600(D)x 1355(H)
SN2212B530(W)x 460(D)x 1105(H)
 

 

Hot Products

IEC 60879-2019 Ceiling Fans Environmental Test Chamber Energy Efficiency Testing Lab Overview: This ...
IEC 60879-2019 Electric Table Fans Floor Fans Energy Efficiency Test Chamber Overview: This test ...
IEC 60456 Washing Machines Performance Testing Room Energy Efficiency Enviromental Lab Product ...