Home Companies Sinuo Testing Equipment Co. , Limited

IEC60695-11-10 / 20 Horizontal And Vertical Flame Test Chambers For Plastics

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC60695-11-10 / 20 Horizontal And Vertical Flame Test Chambers For Plastics

Country/Region china
City & Province guangzhou guangdong
Categories Cable Manufacturing Equipment
InquireNow

Product Details

 

IEC60695-11-10 / 20 Horizontal And Vertical Flame Test Chambers For Plastics

 

Overview:

 

This horizontal and vertical burning test device is used to test the flammability of plastic materials for parts of equipment and appliances. accord with IEC60695-11-3,IEC60695-11-4,IEC60695-11-10,IEC60695-11-20 And the requirements of the UL94 standard.

 

The chamber has a volume of at least 0.5 m3. The combustion chamber has a large sight flow glass on the door to observe the ongoing test, and the chamber is ventilated freely, allowing normal thermal circulation of air through the test sample during combustion. The internal surface area of the box should be painted dark. When measuring with the photometer, place the box facing the rear of the box in the sample position. The luminance should be less than 20lx. For safety and convenience, the enclosure (which can be fully enclosed) is fitted with an air extraction device, such as an exhaust fan, to remove potentially toxic combustion products. The suction device can be closed during the test and opened immediately after the test to remove the fire waste water. A positive closing damper can be configured.

 

Technical Parameters:

 

Flames50W flame500W flame
Standards applicationIEC60695-11-4, IEC60695-11-10, UL94IEC60695-11-3, IEC60695-11-20, UL94
Timing device0~9999, resolution:0.1s0~9999, resolution:0.1s
Combustion angle0°, 20°, 45°0°, 20°, 45°
Gas pressure0.1 MPa0.1 MPa
Height of flameTotal height 20±2mmInner flame 40±2mm total height 125
Distance for temperature measurement10±1mm55±1mm
Standard for blast burnerIEC60698-11-4, UL94IEC60695-11-3, UL94
Temperature rangeMax. 1100℃, thermocouple: type KMax. 1100℃, thermocouple: type K
Gas flow rate105 ml/min±5 ml/min965 ml/min±30 ml/min
Water column height<10mm125mm±5mm
Temperature rising timeFrom 100℃±5℃ to 700℃±3℃ is 44s±2sFrom 100℃±5℃ to 700℃±3℃ is 54s±2s
Accuracy of flow rate1%1%
Weight of copper block

Ф5.5mm,

1.76 g±0.01 g

(before drilling)

Ф9mm,

10g±0.05 g

(before drilling)

Type of gasMethane or coal gasMethane or coal gas
Volume of chamber0.75m³, black inner painted
ControlButton operation + remote controller
DisplayDigital display
Using environment

15 °C to 35 °C temperature,

45 % to 75 % relative humidity

 
 
Working Principle:

 

According to a certain flame height and a certain flame angle, multiple flames were applied to the sample in the horizontal or vertical state, and the flammability of the sample was evaluated according to the afterflame time, afterglow time and whether the underlayer of the sample was ignited.

The company can provide all kinds of test equipment according to the requirements of IEC, BS, VDE, Unilever, GB, ISO and other standards, and can customize the test system or equipment according to the specific requirements of customers. We have our own senior professional technical team, and cooperate with colleges and universities, scientific research institutions, coupled with our strong manufacturing capabilities, we can provide customers with rapid response and one-stop service.

 

Hot Products

IEC 61591: 2014 Range Hood Air Performance (Air Volume) Testing System For Pressure Efficiency Test ...
IEC 60879 Tower Fan Table Fans Energy Efficiency Performance Test Chamber Standards Application: IEC ...
IEC60335-2-21 Heating Performance Testing Machine For Range Hood Standards for Range Hoods Heating ...
VDE 0620-1-2005 Abnormal Heat Of Insulating Sleeves Of Plug Pins Testing Apparatus Product ...
IEC60335-2-25 Microwave Oven Door & Refrigerator Door Endurance Test Machine Product Information: ...
IEC60335-2-17 Electric Blanket Spark Ignition Test Device For Test The Flame Resistance Product ...