Home Companies Sinuo Testing Equipment Co. , Limited

IEC 60884-1 Electric Shock Prevention And Plug Socket Contact Sequence Tester

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 60884-1 Electric Shock Prevention And Plug Socket Contact Sequence Tester

Country/Region china
City & Province guangzhou guangdong
Categories Other Roadway Products
InquireNow

Product Details

 

IEC 60884-1 Electric Shock Prevention And Plug Socket Contact Sequence Tester

 

Product Information For Electric Shock Prevention And Plug Socket Contact Sequence Tester:

 

Standard: IEC60884-1:2006 "Plugs and socket-outlets for household and similar purposes - Part1: General requirements" clause 11

 

Sample: Household electrical accessories with grounding contacts

 

Test purpose: It’s used for structural performance requirements for the contact sequence of plugs, sockets, electrodes and pins

 

Technical Parameters For Electric Shock Prevention And Plug Socket Contact Sequence Tester:

 
ModelSN2210-19T
Test stationSingle
Electrical control methodElectrical Intelligent Integrated Control
Test items

1. Anti-shock test

2. Contact sequence test

Use environmentPower supply: AC220V±10%/50-60Hz, power 0.5kW
 
Test Steps For Electric Shock Prevention And Plug Socket Contact Sequence Tester:
 

1. Connect the power plug of the device to the power grid (220V~), turn on the power switch, and the reset light is on, that is, turn on the power, and press the reset button to make the instrument enter the initial state.

2. Insert the wire connecting the socket and plug into the terminal corresponding to the socket and plug of the instrument.

3. Insert the socket and plug together, and then you can judge whether it is qualified or not (if the ground electrode is in contact with the electricity first, it will be judged as qualified, otherwise it will be unqualified).

4. Pull out the plug from the socket, and then you can judge whether it is qualified or not (if the ground pole is disconnected at the end, it is judged as qualified, otherwise it is unqualified; if the plug is inserted into the socket, the three poles must be in contact with power before pulling out discrimination).

5. After the test is completed, press the reset button to make the machine enter the initial state of the next test.

6. The output voltage of the anti-electric shock test is AC 40~50V, and it is tested with various anti-electric shock probes. If it is turned on, the indicator light will light up.

 

Hot Products

ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
IEC61855 Figure 9 Dryer Air Volume Test System For Household And Similar Purposes Standards: QB...
Dryer Air Volume Test Equipment For Measure Air Volume Or Airflow Performance Of Dryer IEC 61855 ...
IEC 61591: 2014 Range Hood Air Performance (Air Volume) Testing System For Pressure Efficiency Test ...
IEC 60879 Tower Fan Table Fans Energy Efficiency Performance Test Chamber Standards Application: IEC ...
Automatic Test Drying Rate Testing Device For Hair Dryer With PLC Control IEC 61855 Product ...