Home Companies Sinuo Testing Equipment Co. , Limited

IEC 60884-1 2022 7 In One Modular Integrated Information Safety Analyzer

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 60884-1 2022 7 In One Modular Integrated Information Safety Analyzer

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

 

IEC 60884-1: 2022 7 In One Modular Integrated Information Safety Analyzer

 

Product Information For Modular Integrated Information Safety Analyzer:

 

This 7 in one electrical safety tester Conforms to IEC 60884-1:2022 clause 11, 17, IEC 60669-1:2017 clause 11 and Clause 16, IEC 60950:2013 clause 2.6.3.4, 5.2 and 6.2.2.3, IEC 60335-1 Clause 13, Clause 16, Clause 27 and etc. It integrates 7 functions of AC withstand voltage, DC withstand voltage, insulation, grounding, leakage, power, low-voltage start testing.

 

Features For Modular Integrated Information Safety Analyzer:

 

Global new modular information and safety regulation integrated analyzer, safety regulation function modular, realize information interconnection, with data acquisition, storage, analysis,

Transmission and other functions, is the best solution of the Internet factory detection.

■ 12-inch full-color touch screen, built-in touch keyboard, fast input;

■ Independently develop test system software to fully meet the requirements of intelligent testing;

■ Local storage of test data, which can be connected with MES and other information management systems;

■ Main item accuracy 1%, power test accuracy 0.2%;

■ Diversified communication modes: WIFI, network port, USB, RS232, RS485, CAN

■ Modular modular: each function module card design, multi-function selection, modular function customization, the establishment of sales service innovation system.

■ Parallel test parallel test: withstand voltage insulation and grounding can be tested at the same time, greatly shorten the overall test time, improve the test efficiency.

■ Fault self-diagnosis fault self-diagnosis: display the cause of equipment failure, with remote upgrade and modular design, to achieve a quick solution to equipment problems.

■ Remote Upgrade Remote upgrade: Remotely upgrade the latest version of the software to solve problems encountered in the use of the software and update the customization requirements.

■ Rapid discharge rapid discharge: rapid discharge patented technology, to achieve the measured object within 50ms discharge.

■ Anti-high voltage anti-high voltage GFI: : real-time monitoring loop, self-dynamic measurement of the measured object state, if there are personnel contact high voltage loop, automatically disconnect high voltage output, eliminate

Electric shock injury to ensure personnel safety

■WiFi function: it can connect to wireless network and mobile hotspot, realize network information transmission, remote diagnosis, remote upgrade and other networking functions.

■ Built-in power supply built-in power supply: frequency conversion power supply built-in, can real-time output voltage and frequency testing required, built-in power within 6KVA, more power

Can be customized.

■ Arc detection Arc detection: by detecting the abnormal current circuit of the tested object, screen out the exposed short-circuit defective products,

Bar code scanning: bar code start test, bar code test group and other functions, bar code and test data interconnection, easy data management and analysis.

■ Data management data management: real-time display of statistical data in the form of charts, conducive to data analysis and management, compatible with databases, and MES and other information systems docking.

 

Technical Parameters For Modular Integrated Information Safety Analyzer:
 
ModelTest ProjectFunctionAccuracy
ACWDCWIRGBLCPWRSTRO/SVariable frequency power supplyTransformer1%
SN6872F  

 

AC Withstand Voltage (ACW)
Rated output5KV/100mA, short-circuit current>200mA
The output voltage range100 ~ 5000V
Output voltage accuracy±(1%× set value +2 words)
Voltage resolution1V
Output frequency50/60Hz
Frequency accuracy±0.1Hz
Output adjustment±(1%× set value +2 words)
Current upper limit0.00 to 100.00mA
The current lower limit0.000 to 9.999mA
Current measurement range0.00 ~ 100.0mA
The current measurement resolution0.001/0.01mA
Current measurement accuracy±(1%× reading value +5 words)
Slow rise time0-999.9s
Slow down time0.1-999.9s
Test time0,0.3-999.9s
Time resolution0.1s
Time accuracy±(0.2% x set value +1 word)
Arc detection0-9
Current compensation range0.000-20.00mA
 
DC Withstand Voltage (DCW)
Rated output6KV/10mA
The output voltage range200~6000V
Output voltage accuracy±(1%× set value +2 words)
The output ripple<2%
Current upper limit0.00 to 10.00mA
The current lower limit0.000 to 9.999mA
Current measurement range0.00 ~ 10.0mA
The current measurement resolution0.001/0.01mA
Current measurement accuracy±(1%× reading value +5 words)
Slow rise time0-999.9s
Slow down time0.1-999.9s
Test time0,0.3-999.9s
Time resolution0.1s
Time accuracy±(0.2% x set value +1 word)
Arc detection0-9
Current compensation range0.000-5.000mA
Discharge time100ms
 
Insulation Resistance (IR)
Rated output2500V/50GΩ
The output voltage range200~2500V
Voltage resolution1V
Output voltage accuracy±(1%× set value +2 words)
Ripple coefficient≤2%
Resistance measuring range0.00 to 10.00mA
Resolution of resistance measurement0.000 to 9.999mA
Accuracy of measurement

1.000MΩ~999.9MΩ

Output 200-500V

±(7%× reading value +3 words)

1.000MΩ~999.9MΩ

Output 501-2500V

±(5%× reading value +3 words)

1.00GΩ~10.00GΩ

Output 501-2500V

±(7%× reading value +3 words)

10.00GΩ~50.00GΩ

Output 1000-2500V

±(15%× reading value +3 words)
Slow rise time0-999.9s
Slow down time0.1-999.9s
Test time0,0.3-999.9s
Time resolution0.1s
Time accuracy±(0.2% x set value +1 word)
Discharge time<100ms
 
Grounding Resistance (GR)
Rated output32A/600mΩ
The output voltage range1.00~32.00A
Voltage resolution0.01A
Output voltage accuracy±(1%× set value +3words)
Current fluctuations≤0.4% x Set value/min
The output voltage3.00-8.00V AC
The resolution of the0.1V
The output frequency50Hz/60Hz
Frequency accuracy±0.1Hz
Upper/lower resistance setting0.1-600mΩ
Resistance range0.1-600mΩ1.00~10.00A

0.1 the Rm Ω

R=(6400/ set current value)m ω

10.10~64.00A
Resolution of resistance measurement0.1/1mΩ
Accuracy of resistance measurement±(1%× reading value +3 words)
Voltage measuring range0.00-6.40V AC
Voltage measurement resolution0.01V
Accuracy of voltage measurement±(1%× reading value +3 words)
Resistance compensation0-100mΩ
The test of time0,0.3-999.9s
Temporal resolution0.1s
Time accuracy±(0.2%× reading value +3 words)
 
Touch current/leakage current

Test Probe Setup

 

Ground contact current: G-L, G-N, AUTO (G-L, G-N)
Contact current to surface: PH-L, PH-PL
7 kinds of human body simulation circuits (MD) are standard (optional customized human body network)MD A.

GB12113/IEC60990,GB4706.1/IEC60335-1

GB7000.1/IEC60598-1,GB4943.1/IEC60950-1

GB4793.1/IEC61010-1,GB8898.1/IEC60065

MD B.UL1563
MD C.GB9706.1/IEC60601-1
MD D.

UL544P

 

MD E.UL544NP/UL484/UL923/ UL1029/UL471/UL867/UL697
MD F.

GB12113/IEC60990

GB7000.1/IEC60598-1

MD G.

GB4943.1/IEC60950-1

GB4793.1/IEC61010-1

Test power supply

 

 

Polarity Switching: On, Off, Auto
Grounded and Un-grounded Conversion: On, Off
The transition between the normal connection state and the non-connection state of the neutral line of the test power supply: ON, OFF
Test voltage outputSingle-phase, requires an external isolation transformer or variable frequency power supply; provides the voltage and frequency required for the test.
Test voltage upper limit setting0.0V~300.0V AC
Test voltage lower limit setting

0.0V~300.0V AC

 

Test voltage resolution

0.1V ;

45Hz~65Hz

Test voltage measurement range0.0V~300.0V,45Hz~65Hz
Test voltage resolution0.1V,45Hz~65Hz
Test voltage measurement accuracy20.0V~300.0V: ±(2%×reading value+3 digits)
load current20A
Overcurrent ProtectionRMS current and response time: 25A<3s
Peak current and response time: 70A<10ms
Touch current measurement upper limit (effective value)0.0mA~20.000mA
Touch current measurement lower limit (RMS)0.0mA~20.000mA
Touch current measurement resolution (RMS)0.001mA
Touch current measurement judgment error (RMS)AC±(1%×reading value+3 digits)

15Hz≤f≤

100kHz

±(1%×reading value+3 digits)

100kHz<f≤

1000kHz

 

±(2%×reading value+3 digits)
Touch current compensation range0.000~1.000mA; automatic measurement; can be turned on or off
testing time0; (1 ~999.9); 0 is infinite
Test time resolution0.1s
test accuracy±( 1% × set value + 1 word)
test methodAUTO (G-L, G-N); time for 1 and a half times each
 
Load Power
Power upper/lower limit settings0.0~6000W
Power measurement range0.0-999.9W,1000-6000W
Power measurement resolution0.1W,1W
Power Measurement AccuracyPF>0.9±(0.1%×reading value+0.1%×range)
PF≤0.9±(0.4%×reading value+0.1%×range)
Voltage measurement range0.0-300.0V
Voltage measurement resolution0.1V
Voltage measurement accuracy±(0.1%×reading value+0.1%×range)
testing time0,0.3~999.9s
Time resolution0.1s
time accuracy±(0.2%×setting value+1 word)
 
Low Voltage Start
Current upper/lower limit setting0.00-20.00A
Current measurement range0.000-9.999A ,10.00-20.00A
Current measurement resolution0.001A/0.01A
Current measurement accuracy±(0.1%×reading value+0.1%×range)
Voltage measurement range0.0-300.0V
Voltage measurement resolution0.1V
Voltage measurement accuracy±(0.1%×reading value+0.1%×range)
testing time0,0.3~999.9s
Time resolution0.1s
time accuracy±(0.2%×setting value+1 word)
 
Configuration
Communication InterfaceWIFI, network port, USB, RS232 (optional RS485, CAN)
Dimensions (W×H×D), mm550*1360 (including casters without alarm light) *600
Accessories (standard)Test box, test clamp, foot switch, alarm light, instruction manual
 
 

Hot Products

ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
IEC61855 Figure 9 Dryer Air Volume Test System For Household And Similar Purposes Standards: QB...
Dryer Air Volume Test Equipment For Measure Air Volume Or Airflow Performance Of Dryer IEC 61855 ...
IEC 61591: 2014 Range Hood Air Performance (Air Volume) Testing System For Pressure Efficiency Test ...
IEC 60879 Tower Fan Table Fans Energy Efficiency Performance Test Chamber Standards Application: IEC ...
IEC 60335-2-24 Hydraulic Pressure Test Apparatus For Pressure Resistance Test Product Information ...