Home Companies Sinuo Testing Equipment Co. , Limited

IEC 60884-1 2022 Compression Testing Apparatus For VDE Type Plugs Sockets

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 60884-1 2022 Compression Testing Apparatus For VDE Type Plugs Sockets

Country/Region china
City & Province guangzhou guangdong
Categories Connectors
InquireNow

Product Details

 

IEC 60884-1: 2022 Compression Testing Apparatus For VDE Type Plugs Sockets

 

Product Information For Compression Testing Apparatus:

 

The specimens are subjected to a compression test as shown in figure 8 of IEC 60884- 1:2013, the temperature of the pressure plate, of the base and of the specimens being (23±2) ℃ and the force applied being 300 N.

The specimens are first placed in position a), as shown in figure 8 of IEC 60884-1, and the force is applied for 1 min. They are then placed in position b), as shown in figure 8 of IEC 60884-1, and again subjected to the force for 1 min.

The specimens are removed from the test apparatus and after 15 min they shall show no damage within the meaning of this standard.

 

Technical Parameters For Compression Testing Apparatus:

 

Number of Test Station1
Operating methodBy manual
Weight150N and 300N (consists of 2 pc of 150N weight)
Conforms to standardIEC 60884-1 Clause 10.1, Clause 24.5, Fig8
 

Test method For Compression Testing Apparatus:

 

1. Put the apparatus in a constant temperature environment for testing, and keep the temperature of the pressure plate, base and sample at 23±2℃.

2. Rotate the handle to lift the weight, place the sample directly under the pressing block as shown in Figure a below, rotate the handle to lower the weight, make the sample bear a force of 300N, and start timing for 1min.

3. After 1min, place the sample as shown in Figure b, and bear the force of 300N again for 1min.

4. After the sample is removed from the test device for 15 minutes, the sample should not appear damaged within the standard meaning.

 

Notice:

 

1. Please do not damage the appliance shape (such as scratching, bending, etc.).

2. Prevented from dust and moisture environment, in order to avoid the oxidation to affect the dimensional accuracy.

 

 

 

Hot Products

Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...
5RT Air Enthalpy Laboratory Air Conditioner Energy Efficiency Performance Lab System overview This ...
IEC61855 Figure 9 Dryer Air Volume Test System For Household And Similar Purposes Standards: QB...
Dryer Air Volume Test Equipment For Measure Air Volume Or Airflow Performance Of Dryer IEC 61855 ...