IEC 60884-1 2022 Label Marking Abrasion Test Apparatus For VDE Type Plug Socket

Country/Region china
City & Province guangzhou guangdong
Categories Connectors
InquireNow

Product Details

 

IEC 60884-1:2022 Label Marking Abrasion Test Apparatus For VDE Type Plug Socket

 

Product Information For Label Marking Abrasion Test Apparatus:

 

This label marking abrasion test apparatus conforms to IEC 60884-1: 2022 Clause 8.8 figure 5, IEC 60669-1: 2017 Clause 8.9, etc.

 

Technical parameters For  Label Marking Abrasion Test Apparatus:

 

Test stations2 stations
Test stroke10-60mm, adjustable(Manually adjustable)
Speed5-60 times /min, adjustable
Counter0-9999 adjustable
Compression force5N±1N, 2 pieces
Test Piston

Two pieces of test pistons, designed according to IEC 60884-1: 2022 figure 5, made of an elastic material and has a Shore-A hardness of 47±1 (for example synthetic rubber)

 

VoltageAC 220V±10%, 60Hz
 

Troubleshooting For Label Marking Abrasion Test Apparatus:

 

1 If the POWER is turned on, the instrument is not powered on or the power indicator is not light: if the power indicator is damaged, replace the indicator; if there is no power output at the power output terminal, please check the power cord or power socket-outlet.

2 If the power is turned on, the power indicator lights, but the machine does not work when operator presses the SWITCH button. Please check whether there is a disconnection. If there is a disconnection, please connect it in time. If there is no disconnection of the relay, indicating that the counter is damaged, the counter should be replaced in time.

3 When the number of times set on the counter is finished, but the motor does not stop working, indicating that the counter is damaged.

4 If the power indicator light is on but the counter has no display, it means that the counter is damaged and the counter needs to be replaced.

 

Maintenance Notes For Label Marking Abrasion Test Apparatus:

 

1 The instrument must be placed on a stable surface before use.

2 It is not allowed to move the machine during use.

3 Select the appropriate power supply voltage, should not be too high, to avoid burning the instrument.

4 If the instrument works abnormal, please contact with us for timely processing.

5 The instrument must be used in a good ventilation environment.

6 Please add lubricating oil to the mechanical transmission part in time due to the large operating load of each component of the button mechanism.

7 After each test is completed, operator should clean the machine.

8 The control box part must be wiped with a dry cloth.

 

 

 

 

 

Hot Products

Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...
5RT Air Enthalpy Laboratory Air Conditioner Energy Efficiency Performance Lab System overview This ...
IEC61855 Figure 9 Dryer Air Volume Test System For Household And Similar Purposes Standards: QB...
Dryer Air Volume Test Equipment For Measure Air Volume Or Airflow Performance Of Dryer IEC 61855 ...