Shanghai Shenghua Cable (Group) Co., Ltd. |
Verified Suppliers
|
|
Three Cores or More 450V / 750V Fire Resistant Cables Mica Tape PE
Insulation PVC Sheath FR Cable
Structure
Conductor : Class 1, 2, 5 as per IEC60228 Copper Conductor
Screen: Mica tape
Insulation: PVC or PE
Sheath: PVC/PE/LSOH
Rated Voltage : 450/750V
Standards
International: IEC 60227
China: GB/T 5023-2008
Other standards such as BS,DIN and ICEA upon request
Application
Flexible cable for medium mechanical stresses. Permitted frequent
bending and twisting. Specially suitable for application in
household, kitchens and offices in dry and damp conditions, for
inst. washing-machines, dryers, refrigerators etc., as long as the
cable is adapted to essential specifications of the device. Also
suitable for cookers, i.e. hot devices, on condition that it does
not get in direct contact with hot parts of the device and is not
exposed to heat irradiation. Suitable for fixed installation in
furniture, partition walls, decorative linings and cavities in
prefabricated construction elements
Technical Data
Temperature range :
during installationi : +5 °C up to +70 °C
fixed installed : -30 °C up to +70 °C
at short circuit of max. 5 s : up to 150 °C
ambient temperature at storage : up to 40 °C
Nominal voltage : Uο/U = 300/500 V
Test voltage : 2000 V
Minimal inner bending radius : 4D for D < 8 mm
5D for 8 - 12 mm
6D for D > 12 mm
Specifications for flexible fire cable wires
corexsection mm2 | conductor structure | External diameter mm | Insulation thickness mm | Sheath thickness mm | Conductor resistance at 20 °C Ω/km | Specific. el. resistance of insulation at 70°C MΩkm |
2x0.75 | 24x0.2 | 5.7-7.2 | 0.6 | 0.8 | 26.0 | 0.011 |
2x1 | 32x0.2 | 5.9-7.5 | 0.6 | 0.8 | 19.5 | 0.010 |
2x1.5 | 30x0.25 | 6.8-8.6 | 0.7 | 0.8 | 13.3 | 0.010 |
2x2.5 | 50x0.25 | 8.4-10.6 | 0.8 | 1.0 | 7.98 | 0.0095 |
3x0.75 | 24x0.2 | 6.0-7.6 | 0.6 | 0.8 | 26.0 | 0.011 |
3x1 | 32x0.2 | 6.3-8.0 | 0.6 | 0.8 | 19.5 | 0.010 |
3x1.5 | 30x0.25 | 7.4-9.4 | 0.7 | 0.9 | 13.3 | 0.010 |
3x2.5 | 50x0.25 | 9.2-11.4 | 0.8 | 1.1 | 7.98 | 0.0095 |
3x4 | 56x0.3 | 10.5-13.1 | 0.8 | 1.2 | 4.95 | 0.0078 |
4x0.75 | 24x0.2 | 6.6-8.3 | 0.6 | 0.8 | 26.0 | 0.011 |
4x1 | 32 x 0,20 | 7,1 - 09,0 | 0.6 | 0.9 | 19.5 | 0.010 |
4x1.5 | 30 x 0,25 | 8,4 - 10,5 | 0.7 | 1.0 | 13,3 | 0,010 |
4x2.5 | 50 x 0,25 | 10,1 - 12,5 | 0,8 | 1.1 | 7,98 | 0,0095 |
4x4 | 56 x 0,30 | 11,5 - 14,3 | 0,8 | 1.2 | 4,95 | 0,0078 |
4x6 | 84 x 0,30 | 14,7 | 0.8 | 1.2 | 3,30 | 0,0068 |
5x0.75 | 24 x 0,20 | 7,4 - 9,3 | 0.6 | 0.9 | 26.0 | 0.011 |
5x1 | 32 x 0,20 | 7,8 - 9,8 | 0.6 | 0.9 | 19.5 | 0,010 |
5x1.5 | 30 x 0,25 | 9,3 - 11,6 | 0.7 | 1.1 | 13.3 | 0,010 |
5x2.5 | 50 x 0,25 | 11,2 - 13,9 | 0.8 | 1.2 | 7,98 | 0,0095 |
Operation Feature
1. Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C;
2. Installing temperature of cable should not be less than 0°C;
3. Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec;
4. Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
5. Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
Choose US!