RS422 RS485 YOKOGAWA Transmitter Module ALR121-S00

Country/Region china
City & Province hong kong
Categories Measuring & Analysing Instrument Agents
InquireNow

Product Details

YOKOGAWA RS422/RS485 Module ALR121-S00

Models ALR111 and ALR121 Serial Communication Modules used with a safety control station (SCS) for performing Modbus communication.

By using the SCS’s Modbus slave communication function, the data in SCS can be set or referred to by the Modbus master which is as separate system from SCS via a serial communication module. Furthermore, the subsystem

data such as from sequencers can be set or referred to via a serial communication module using SCS’s subsystem communication function.

These serial communication modules can be mounted on a safety control unit and a safety node unit.

 

Hardware specifications of ALR111 and ALR121 serial communication modules are as shown below. These modules are interference-free modules that have no interference with the safety loop.

 

Table Serial Communication Module Hardware Specifications

 

ItemSpecifications
ModelALR111ALR121
InterfaceRS-232CRS-422/RS-485 (4-wire system)
Connection methodPoint-to-point

Point-to-point (RS-422)

Multipoint (RS-485)

Communication functionHalf-duplex
Synchronization methodStart-stop synchronization
Transmission speed1200/2400/4800/9600/19200/38400 bps
Transmission codebinary
Character length8 bits (Fixed to 8 bit on the Modbus slave communication function and the subsystem communication function)
Stop bit length1/2 bits (Fixed to 1 bit on the subsystem communication function)
Parity checkNone/even/odd
Lag time after data transmission1 ms
Transmission distanceMaximum 15 mMaximum 1200 m (total extended length)
Installation methodMounted on S2SC70 , SSC60 , SSC50 , SSC57 , or SNB10D
I/O wiringAKB131, AKB132, AKB135, AKB136 cables, etc.Cable with 3-pair shield, AKB161, or AKB162
Wiring connectionD-sub-9-pin (female × 2 ports)Clamped with terminal block’s M4 screws (5 poles × 2 ports)
Communication function (*1)Modbus slave communication function, subsystem communication function
Current consumption0.5 A0.5 A
WeightApprox. 0.3 kgApprox. 0.34 kg

*1: A unit of SCS is capable of handling multiple communication functions: however, different types of communication functions cannot be simultaneously performed on a serial communication module. It means that two ports must have identical

communication functions.

 

Related Part Number:

 

AAI135-S00
AAI143-H00
AAI143-H53
AAI143-S50
AAI543-S00
AAI835-H00
AAI835-H00/K4A00
AAI835-S00
AAI835-S50
AAM51
AAT145-S00
ACCC01
ACM12
ACM12
ADM11c
ADM12
ADM52C
ADV151-P00
ADV151-P50/D5A00
ADV151-P63
ADV151-P63/D5A00
ADV159-P00
ADV551
ADV551-P50/D5A00
ADV551-P63
AED5D-00
AIP601
AIP826
AIP827-2
AIP830-101
AIP830-101-EIM-VESA
AKB331-M020
ALE111-S50
ALE111-S51
ALR121-S00
AMN33
ATD5A-00
ATK4A-00
AX01C-C010-CH
AX01C-C015/CH

 

Hot Products

EJA120E Diff erential Pressure Transmitte EJA120E-JES4J-812EB The high performance draft range diff ...
EJA530E In-Line Mount Gauge Pressure Transmitter EJA530E-JBS4N-019EL The EJA-E series of transmitter...
EJA130E Differential Pressure Transmitter EJA130E-DMS5J-912NB The high performance diff erential ...
EJX110A Differential Pressure Transmitter EJX110A-EMS4G-919DB/KU22/N4 The high performance diff ...
EJX110A Differential Pressure Transmitter EJX110A-EMS5G-919DB/KS21/D4 The EJX-A series is Yokogawa's ...
EJA130E Differential Pressure Transmitter EJA130E-JMS4G-712DD/D4 The EJA-E series of transmitters is ...