Home Companies SC Automation Limited

MTL5516C Switch MTL Safety Barrier Proximity Detector Interface 35mA 24V

SC Automation Limited

Contact Us

[China] country

Trade Verify

Address: Unit 1406B 14/F,The Belgian Bank Building, Nos. 721-725 Nathan Road, Mongkok, Kowloon,Hong kong.

Contact name:Joy chen

Inquir Now

SC Automation Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

MTL5516C Switch MTL Safety Barrier Proximity Detector Interface 35mA 24V

Country/Region china
City & Province hong kong
Categories Testing Equipment
InquireNow

Product Details

MTL5516C SWITCH/ PROXIMITY DETECTOR INTERFACE

The MTLx516/C enable two safe-area loads to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the line- fault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for each channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.

 

SPECIFICATION

 

Number of channels

Two

Location of switches

Zone 0, IIC, T6 hazardous area

Div. 1, Group A hazardous location

Location of proximity detector

Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location

Hazardous-area inputs

Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)

Voltage applied to sensor

7 to 9V dc from 1kΩ ±10%

Input/output characteristics

Normal phase

Outputs closed if input > 2.1mA (< 2kΩ in input circuit) Outputs open if input < 1.2mA (> 10kΩ in input circuit)

Hysteresis: 200µA (650Ω) nominal

Line fault detection (LFD) (when selected)

User-selectable via switches on the side of the unit. Line faults are indicated by an LED for each channel. The channel output relay is de-energisedif an input line fault is detected.

Open-circuit alarm on if Iin < 50µA

Open-circuit alarm offif Iin > 250µA

Short-circuit alarm on if Rin < 100Ω

Note: Resistors must be fitted when using the LFD facility with a contact input 500Ω to 1kΩ in series with switch

20kΩ to 25kΩ in parallel with switch

Safe-area output

Two single-pole relays with changeover contacts

Note: reactive loads must be adequately suppressed

Maximum current consumption

35mA at 24V

Power dissipation within unit

0.84W at 24V

LED indicators

Green: power indication

Yellow: two: channel status, on when output energised

Red: two: LFD indication, on when line fault detected

 

Related Part Number:

 

 

HCU16

MTL5521

MTL4546Y

MTL7761PAC

HCU3700

MTL5522

MTL4549Y

MTL7765AC

HM64RIB20-1.0

MTL5531

MTL4573

MTL7787+

HM64RIB20-1.5

MTL5532

MTL4575

MTL7787P+

HMM64

MTL5541

MTL4646Y

MTLCPS16

HMRIB16-1.0

MTL5541S

MTL4850

NJ5-18GK-N

HMS64

MTL5544

MTL4851

SD150X

HTP-SC32

MTL5544D

MTL4852

SD32

MTL4044D

MTL5546

MTL5018

SD32X

MTL4511

MTL5546Y

MTL5032

SDRTD

MTL4516

MTL5561

MTL5042

SLP32D

MTL4516C

MTL5573

MTL5044

TP48-3-I-NDI

MTL4521

MTL5575

MTL5049

TP48-3-N-NDI

MTL4541

MTL5582B

MTL5511

TP48-4-I-NDI

PCL45USB

MTL7728+

MTL5514D

TP48-4-N-NDI

MTL4544

MTL7756AC

MTL5516

TP48-N-NDI

MTL4544D

MTL7760AC

MTL5516C

ZB24571

 

 

 

Hot Products

Emerson Ovation Analog Input Module 1C31113G05 Emerson offers a wide inventory of factory-certified ...
Rosemount 751 Field Signal Indicator 751AM7I5 Product Description Gain access to important process ...
Rosemount 396 Submersion/Insertion pH Sensor 396-54-62 TUpH sensors for your tough pH/oxidation ...
Rosemount 3051T In-Line Transmitter 3051TG5A2B21AB4M5K5HR5 Rosemount 3051T In-Line Pressure ...
Rosemount 3051C Coplanar Pressure Transmitter 3051CD2A22A1BI1M5Q4 Rosemount 3051C Coplanar Pressure ...
Bently Nevada 3500/65 16-Channel Temperature Monitor 3500/65-01-00 145988-02 172115-01 Description ...