Home Companies SC Automation Limited

Zone 0 Mtl5546 Isolating Driver Sic Isolated Gate Driver

SC Automation Limited

Contact Us

[China] country

Trade Verify

Address: Unit 1406B 14/F,The Belgian Bank Building, Nos. 721-725 Nathan Road, Mongkok, Kowloon,Hong kong.

Contact name:Joy chen

Inquir Now

SC Automation Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Zone 0 Mtl5546 Isolating Driver Sic Isolated Gate Driver

Country/Region china
City & Province hong kong
Categories Flow Measuring Instruments
InquireNow

Product Details

MTL5546 ISOLATING DRIVER

The MTLx546 accepts a 4/20mA floating signal from a safe-area controller to drive a current/pressure converter (or any other load up to 800Ω) in a hazardous area. For HART valve positioners, the module also permits bi-directional transmission of digital communication signals. Process controllers with a readback facility can detect open or short circuits in the field wiring: if these occur, the current taken into the terminals drops to a preset level. The MTL4546C and the MTLx546Y are very similar to the MTLx546 except that they provide open circuit detection only (i.e. no short-circuit detection).

 

SPECIFICATION

Number of channels

One

Location of I/P converter

Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A, hazardous location

Working range

4 to 20mA

Digital signal bandwidth

500Hz to 10kHz

Maximum load resistance

800Ω (16V at 20mA)

Minimum load resistance

90Ω (short-circuit detection at < 50Ω)

Output resistance

> 1MΩ

Under/over range capability

Under range = 1mA

Over range = 24mA (load ≤ 520Ω)

Input and output circuit ripple

< 40µA peak-to-peak

Transfer accuracy at 20°C

Better than 20µA

Temperature drift

< 1.0µA/°C

Response time

Settles within 200µA of final value within 100ms

Communications supported

HART

LED indicator

Green: power indication

Maximum current consumption (with 20mA signals into 250Ω load)

35mA at 24V dc

Power dissipation within unit (with 20mA signals into 250Ω load)

0.8W at 24V

Safety description

Uo =28V Io =93mA Po =651mW Um = 253V rms or dc

 

​Related Part Number:

 

 

MTL5521

MTL4546Y

MTL7761PAC

MTL5522

MTL4549Y

MTL7765AC

MTL5531

MTL4573

MTL7787+

MTL5532

MTL4575

MTL7787P+

MTL5541

MTL4646Y

MTLCPS16

MTL5541S

MTL4850

NJ5-18GK-N

MTL5544

MTL4851

SD150X

MTL5544D

MTL4852

SD32

MTL5546

MTL5018

SD32X

MTL5546Y

MTL5032

SDRTD

MTL5561

MTL5042

SLP32D

MTL5573

MTL5044

TP48-3-I-NDI

MTL5575

MTL5049

TP48-3-N-NDI

MTL5582B

MTL5511

TP48-4-I-NDI

MTL7728+

MTL5514D

TP48-4-N-NDI

MTL7756AC

MTL5516

TP48-N-NDI

MTL7760AC

MTL5516C

ZB24571

 

 

 

Hot Products

Emerson Ovation Analog Input Module 1C31113G05 Emerson offers a wide inventory of factory-certified ...
Rosemount 751 Field Signal Indicator 751AM7I5 Product Description Gain access to important process ...
Rosemount 396 Submersion/Insertion pH Sensor 396-54-62 TUpH sensors for your tough pH/oxidation ...
Rosemount 3051T In-Line Transmitter 3051TG5A2B21AB4M5K5HR5 Rosemount 3051T In-Line Pressure ...
Rosemount 3051C Coplanar Pressure Transmitter 3051CD2A22A1BI1M5Q4 Rosemount 3051C Coplanar Pressure ...
Bently Nevada 3500/65 16-Channel Temperature Monitor 3500/65-01-00 145988-02 172115-01 Description ...