Home Companies Shanghai Xunhui Environment Technology Co., Ltd.

Handheld ultrasonic Ultrasonic Flow Meters / water flow meter with clamp on transducer

Shanghai Xunhui Environment Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Room 811 Build 143, No. 1399 Husong Road, Shanghai, China

Contact name:Murphy

Inquir Now

Shanghai Xunhui Environment Technology Co., Ltd.

Handheld ultrasonic Ultrasonic Flow Meters / water flow meter with clamp on transducer

Country/Region china
City & Province shanghai shanghai
InquireNow

Product Details

Handheld ultrasonic flow meter with clamp-on transducer for closed pipe flow measurement

 

Product Description

The portable ultrasonic flow meter features the advanced Trans-Phase measuring technology, providing accurate and reliable flow velocity assessments in closed piping systems. It utilizes a non-invasive clamp-on transducer which is placed on the outside of a pipe. Within seconds, the backlit LCD provides stable flowrate readings in cubic meter per hour or meters per second. This product operates on metal or plastic pipes containing liquids with more than 100 ppm of 100 micron or larger suspended solids or entrained gases.

 

Features

  • High accuracy measurement: accuracy: +/-1%, linearity 0.5%, repeatability: 0.2%
  • Small size, light weight
  • Non intrusive measuring, clamp-on transducer, no pressure drop, no pipe disturbance
  • Wide measuring range, DN15 to DN6000mm
  • Large LCD display of: instantaneous flow, accumulated flow (positive, negative and net), velocity, work status, etc.
  • Built in data logger 24K, store over 2000 lines measuring data

Data sheet:

ContentParameters and performance
Main instrumentWork PrincipleTransit-time ultrasonic flow meter
Accuracy2% FS, Repeatability: 0.2%
Displaybacklit LCD, 4 line, 16 digit
Size200x93x33mm, 390g
OperationCompatible 16 key touch key board and simulation keyboard software
InterfaceInsulated RS232, update software, MODBUS
Outputsingle way OCT pulse
Signal cabletwisted pair cable, RS232 communication selection, (5m x 2)
Pipe conditionMaterialsteel, stainless steel, cast iron, copper, cement pipe, PVC, aluminum, glass fiber
DiameterDN15 - DN6000mm
Straight L10D upstream, 5D downstream, and min 30D away from pump
Liquid mediaMedia typewater, ultra pure liquid, solvents, and other fluid liquid
Media temp.Transducer: -30 to 90, (customized: -40 to 160)
Turbidity10000 ppm or below, less bubble
Flow rate0 - 10 m/s, bi-direction
Flow directionbi-direction flow
EnvironmentTemperatureMain unit: -20 - 60
Transducer: -40 - 160
Humidity85% RH
Power supplyAC 110 - 240V

 

Metering Diagram 

Flow measurement                                                Heat measurement

Reference chart

Type

Model

Pipe dia (mm)

Temperature

Dimension (mm)

Clamp on

TS-2

DN15-100

-30-90℃

45x25x32

TM-1

DN50-700

-30-90℃

64x39x44

TL-1

DN300-6000

-30-90℃

97x54x53

Clamp on (high temperature)

TS-2-HT

DN15-100

-30-90℃

45x25x32

TM-1-HT

DN50-700

-30-90℃

64x39x44

TL-1-HT

DN300-6000

-30-90℃

97x54x53

Insertion type

TC-1

DN80-6000

-30-90℃

190x80x55

TC-2(lengthen)

DN80-6000

-30-90℃

335x80x55

Pipe type

G3 (π type)

DN15-25

-30-160℃

 

G2

DN32/DN40

-30-160℃

 

G3

DN50-6000

-30-160℃

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional temperature transducer

Specification

Model

Dia

Temp.

Water cut

Accuracy

Clamp-on temp. transducer Pt100

CT-1

>DN50

-40-160℃

No

100+ 0.8℃

Insertion temp. Transducer Pt100

TCT-1

Yes

Insertion temp. Pt100 with pressure

PCT-1

No

Insertion temp.Pt100 for small pipe D

SCT-1

<DN50

Yes

 

 

 

 

 

 

Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Applications

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

I

Model

 

 

 

 

 

 

 

 

YF

Electromagnetic flowmeter

 

TF

Turbine

 

VF

Votex

 

LX

Vane wheel

 

T

Ultrasonic

 

 

E/F display mode

E: compact/local display, F: remote display

 

 

 

Pipe Dia

Type (mm)

 

 

 

xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 

400, 500, 600, 800, 1000

 

 

 

Code

Accuracy

 

 

 

1

+ 0.5% FS

 

 

 

2

+ 1.0% FS

 

 

 

3

+ 0.2% FS

 

 

 

 

Code

Type

 

 

 

 

N

Converter: 12 / 24 VDC, pulse output

 

 

 

 

A

Transmitter: 24VDC, 4-20mA outpt

 

 

 

 

B

Intelligent, Lion battery, no local display

 

 

 

 

G

Smart, local display, 4-20mA output

 

 

 

 

C1

Smart, local display, RS485

 

 

 

 

C2

Smart, local display, HART

 

 

 

 

 

Code

Type

 

 

 

 

 

S

Carbon steel housing

 

 

 

 

 

L

Stainless steel housing

 

 

 

 

 

G

High pressure housing

 

 

 

 

 

HL

316L electrode

 

 

 

 

 

HTi

Titanium electrode

 

 

 

 

 

HTa

Tantlum electrode

 

 

 

 

 

HC

Hastelloy-C electrode

 

 

 

 

 

L1

Liquid media

 

 

 

 

 

L2

Gas media

 

 

 

 

 

P

Pressure compensation

 

 

 

 

 

T

Temperature compensation

 

 

 

 

 

PT

Pressure&Temp. Compensation

 

 

 

 

 

F

PTFE liner

 

 

 

 

 

X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F, 

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, 

RS485, 316L electrode, liquid media meter, PTFE liner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Calibration

Work shop

Hot Products

High pressure pump Seawater RO Plant for seawater desalination 750 m3 / day 1. Operation Specificati...
Containerized Seawater Reverse Osmosis Plant for drinking water production 500 m3/day 1. Operation ...
Seawater RO Plant with energy recovery for seawater desalination 2x1000 m3 / day​ 1. Operation ...
High TDS seawater RO plant for drinking water production 360m3/hr​ 1. Operation Specifications: Feed ...
High TDS seawater RO plant for drinking water production 360m3/hr​ 1. Operation Specifications: Feed ...
Mobile Containerized Seawater RO Plant for drinking water production 36 m3/hour 750m3/hour 1. ...