Low Temperature Glycol Chiller Laboratory Air Cooled Water Chiller Beverage Seawater Chiller Refrigeration Unit China from shenzhen China

 

Glycol Chiller 

 

Glycol chillers are industrial refrigeration systems that use for glyco mixed with water for anti-freezing, to lower the freezing point of the circulation water in the cooling system. 

Low temperature glycol chiller is a kind of water cooling equipment, it can provide a constant temperature, constant current, constant pressure of a cooling equipment. The glycol chiller water is between 0℃ and -40℃ and the chilled water will be transported to the equipment or products that need cooling through chiller pump.

 

Air-cooled glyco chiller is built-in insulation water tank and water pump, no need to add another cooling tower to heat. It is very easy to install and move. But it has high requirements on the working environment. It is cooled by hot air circulation, so if the ventilation effect of the installation workshop is not good, it will directly affect the refrigeration effect of the chiller.

 

Application

Industrial glycol water chiller unit is used to cool the hot parts of the equipment, so that the equipment can work normally at low temperature. Used in Beverage filling, spindle cooling, CNC machine tools, grinding miller, reaction system, welding machine, cutting machine and other equipment, temperature adjustment range can be 40 degrees below zero.

 

Specification

 

Model

 

AW-40L

 

nominal cooling capacitykcal/h21323
at -25 ℃kw24.80
input powerkw34
power supply3PH~380V 50HZ
refrigeranttypeR404a
 type of controlexpansion valve
compressortypehermetic scroll(piston)
 power(kw)30
condensertypeShell and tube
 chilled fluid flow (m3/h)28.7
 inlet and outlet pipe diameter (inch)2-1/2
evaporatortypePlate heat exchanger
 chilled fluid flow (m3/h)11.98
 inlet and outlet pipe diameter (inch)2-1/2
pumppower (kw)4
 lift(m)20
safety protectioncompressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing
dimensionmm2400*1100*1980
weightkg1600

 

 

The nominal cooling capacity is according to: Inlet chilled fluid temperature: -20℃,supply chilled fluid temperature: -25℃ 

 

Features of glycol chiller cooling system

 

  • The glycol small water chiller use semi-closed piston compressor, high refrigeration efficiency, excellent performance.
  • Glycol solution can be used as a secondary refrigerant. The industrial glycol chiller outlet temperature of chilled water can reach -40 ℃.
  • The COP efficiency of air cooled glycol water chiller is about 2.6-3.3. According to the industrial needs, it can be refrigerated or heated, which is more used in general laboratories and small production lines.
  • The COP efficiency of water-cooled chiller is relatively high, about 4-5.5, which is used in industrial process cooling and large-scale construction projects.
  • Compared with the high efficiency wate cooled chiller, the air-cooled chiller is only different from the condenser. The low-temperature air-cooled chiller dissipates heat directly through the fan, while the water-cooled chiller takes away the heat from the condenser through cold water and dissipates heat through the cooling tower.
  • The water cooled low temperature water chiller can only refrigeration, if the need for heating, need other heating equipment.

 

The proportion of Ethylene Glycol Aqueous Solution of glycol water chiller unit

Operating temperatureConcentrationDensitySpecific heat capacityHeat conductivityViscosityFreezing point
%×10³ Kg/m³KJ/(kg.k)W/m.kPa.s
0251.033.8340.5113.8-10.6
-10351.0633.5610.47267.3-17.8
-20451.083.3120.44121-26.6
-30551.0972.9750.372590-41.6


 

 

 

 

 

Hot Products

Hvac 60HP Industrial Chiller Integrated System 12 Months Warranty 60HP Integrated Screw Type Water ...
220V 380V 415V Industrial Chiller Integrated System Screw Type 40HP Integrated Screw Type Water ...
85HP Industrial Chiller Integrated System Semi Hermetic Screw Type 85HP Integrated Screw Type Water ...
160HP Integrated Water Cooled Screw Type Chiller R22 Refrigerant 160ton Screw Chiller 160ton Water ...
50HP Integrated Water Cooled Chiller System Shell And Tube Package Unit 50HP Integrated Screw Type ...
Integrated Screw Type 75HP Water Cooled Chiller Easy To Operate 75HP Integrated Screw Type Water ...