60TPH Pure Water Treatment Plant RO Water Purification System
 
Product introduction of RO Water Treatment System


The reverse osmosis water purification system uses membrane separation technology to remove charged ions, inorganic substances, colloidal particles, bacteria and organic substances in water. One-time removal of more than 98% of ions, organic matter and 100% of microorganisms in raw water, as well as a variety of dissolved and suspended chemical substances and biological substances (mainly bacteria) in water, and to asbestos, a variety of chemical substances that produce taste, color and odor, Particulate, total dissolved solids, turbidity and radium are also effective for industrial processes and drinking water production.

 
Components and Principles of RO Water Treatment System


The reverse osmosis system includes high pressure pump, reverse osmosis membrane element, pressure vessel (membrane shell), cleaning system and control instrument; the principle of reverse osmosis water treatment system is: when a pressure greater than osmotic pressure is applied on the brine side of the membrane, the water The direction of flow will be reversed, and the water in the brine will flow into the fresh water side, a phenomenon called reverse osmosis.
 
Technical Specifications of RO Water Treatment System

 

ModelJFRO-60T
Host Size7200x1500x1800mm (can be customized)
Power45KW
Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure1.2~1.5MPa
Recovery Rate70%
Designed Water Inlet85t/h
Outlet Flow60t/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size8040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes60
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
High Pressure PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP(Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingFRP
Number of Membrane housing10
Pipe Material

U-PVC/ Stainless steel (Optional)

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Application fields of RO Water Treatment System


1. Water for food and beverage industries
Beverages, dairy, brewing, preparation water, low-level blending water, pure draft beer filtration
2. Bottled and bottled drinking water
Drinking pure water, natural water, mineral water, mineralized water
3. Family and group water purification equipment
High-quality water supply network systems and swimming pool water purification equipment for buildings, communities, hotels, airports, real estate properties

 
Features of RO Water Treatment System
 
(1) The reaction rate is fast and the processing time is short.
(2) It has a wide range of applications, and has a good treatment effect on refractory organic compounds containing azo, carbon double bonds, nitro, and halogenated structures.
(3) The process is simple, the service life is long, the operating cost is low, the operation and maintenance are convenient, and the treatment effect is stable.
(4) The removal rate of chromaticity and COD is high, and the biodegradability of RO concentrated water is improved.

 
Process flow of RO Water Treatment System
 
Original water pump → mechanical filter (quartz sand filter)→ activated carbon filter → sodium ion exchanger (water softener)→ security filter → high pressure pump → reverse osmosis → ozone sterilizer (ultraviolet sterilizer)

 
 
Photos of RO Water Treatment System



 

 

 

 

 

 

 

 

FAQ:
 
1. What are the inlet water quality requirements for ro water treatment system membrane components?

 
Items

NTUSDIResidual chlorine(mg/L)Fe2+(mg/L)TOC(mg/L)
Limits≤1≤5 ≤4≤3

 
 
 
 
  
2. What is the material of ro water treatment system membrane?
 
Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis
 
Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.
 
 
3. RO water treatment system configuration:
 
First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1
 
Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.
 
The arrangement of membrane components can be divided into series and parallel.
 

 
 

Hot Products

60TPH RO Filtration System Water Purifier Desalination Plant Reverse osmosis water system uses ...
Mineral Water RO Water Treatment System 500LPH RO Filter Plant What contaminants will RO Water ...
Double Pass RO Water Purifier Drinking Water Desalination Machine What is Reverse Osmosis Water ...
Commercial RO Water Treatment System 20TPH FRP Water Filter System What contaminants will Ro Water ...
60TPH Pure Water Treatment Plant RO Water Purification System Product introduction of RO Water ...
Wastewater Recycling RO Water Treatment System Water Purified Equipment 200TPH Product introduction ...