Home Companies Guangzhou Kai Yuan Water Treatment Equipment Co., Ltd.

5000LPD Portable Sea Water Treatment System Desalination Plant Salt Water Treatment To Drink

Guangzhou Kai Yuan Water Treatment Equipment Co., Ltd.
Active Member

Contact Us

[China] country

Address: Address: 1floor, C building, Indstrial 3 Road No.38, Jiahe Wanggang, Baiyun District,GuangZhou, China.

Contact name:Andrea Xu

Inquir Now

Guangzhou Kai Yuan Water Treatment Equipment Co., Ltd.

5000LPD Portable Sea Water Treatment System Desalination Plant Salt Water Treatment To Drink

Country/Region china
City & Province guangzhou guangdong
Categories Water Treatment
InquireNow

Product Details

5000LPD Portable Sea Water Treatment System Desalination Plant Salt Water Treatment To Drink

 

 

Sea Water Purification System Details:

 

1. Pretreatment system generally includes the original water pump, dosing system, quartz sand filter, activated carbon filter, precision filter ,and so on. Its main function is to reduce the raw water pollution index and residual chlorine and other impurities, to achieve the reverse osmosis water requirements.Pretreatment equipment configuration of the system should according to the specific situation of the raw water.

 

2. Reverse osmosis unit includes multistage high-pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), support, etc.

 

Its main role is to remove the impurities in the water, the water meets the requirement.

 

3. Post-processing system is in the case of reverse osmosis can not meet the requirement of the water increases the configuration. Mainly includes the Yin bed, sun , sterilization, ultrafiltration of the mixed bed, EDI, etc. One or more of these equipment. Post-processing system can reverse osmosis water.Better improve water quality, to meet the use requirement.

 

4. Cleaning system cleaning tank, cleaning pump, main precision of filter. When the pollution of water reverse osmosis system Index cannot meet the requirements, the need for cleaning of reverse osmosis recovery effect.

 

5. Electrical control system is used to control the normal operation of the reverse osmosis system. Include instrument panel, control panel, all kinds of electricity.Protection, electrical control cabinet and so on.

 

Parameters of 5000LPD RO Seawater Purifier
Product Name
Material
Brand
Usage
Raw Water Pump
Fluoroplastic seawater corrosion -resistance
CNP
Provide needed pressure for every pre-treatment filter
Sand Filter
FRP
China
Remove the water contains sediment, manganese, rust, colloid material, and other particles in the above 20UM of substances hazardous to health.
Anti-dosing system
U-PVC
Italy(SEKO)
To prevent the ro membrane blocking easily.
Security Filter
U-PVC
China
Remove fine particles, sand filters can remove very small colloidal particles in the water, so that the turbidity reached 1 degree.
High Pressure Pump
SUS-316
Danfoss
Provide needed pressure for RO system
RO Membrane
SW30HRLE-4040
USA,Dupont
Can remove particles, colloids, organic impurities, heavy metal ions, bacteria, virus, heat source etc. harmful substances and 97% dissolved salts.
UV Sterilizer /Ozone generator
14W / 3G
China
Kill bacterial in water. UV for direct drinking water. Ozone generator for bottle water

 

Seawater Purification System Performance:

*Main part (membrane) of reverse osmosis system is imported from USA.
*Auto stop when no water and full water.
*Auto controller, RO membrane auto flush to protect membrane.
*Auto start when pure water tank have no water.
*Low pressure protection switch to protect high pressure pump when there is no raw water.
*High efficient and low noise high pressure pump.
*Product water conductivity meter to monitor product water quality all the time.

 

 
Seawater Desalination System Consumable items:
 

There are several kinds of consumables you need to replace regularly. 
a. Quartz sand: replaced about every 15 months. 50kg/bag
b. Activated carbon: replaced about every 15 months. 25kg/bag
c. Resin: replaced about every 15 months. 25L/bag
d. PP Filter cartridge: replaced about every 1 month. 
e. Ro membrane: replaced about every 2 year. 
We suggest you buy 1- 2 years of PP filter cartridges together with machine. Because these PP filter cartridges need to replace every month.
 
Seawater Desalination System Optional Components:
 

A. Regulating wheels

B. PC Touch Screen
C. Two-stage RO system
D. PH adjustment
E. CIP cleaning system
F. Auto or manual control valve
G. U-PVC or stainless steel pipe
H. UV sterilizer/Ozone Generator

 
Some parts function:

 
1. Raw water pump: provide needed pressure for every pre-treatment filter;
2. Quartz sand filter: use fiber glass as housing, fill quartz sand, it can filter big particles impurities, suspended substances, colloids etc. Important to remove iron and sediments you mentioned;^^
3. Antiscalant system: (It is recommended to add H2SO4 to adjust the pH value to avoid CaCO3 precipitation and reduce seawater desalination membrane fouling---cost-effective and no side-effect)
4. Security filter: prevent large particles, bacteria, viruses into RO membrane, accuracy is 5µm;

 
Seawater Desalination System Photos:

 


 

 
 
 

Hot Products

220 Wats Purificadora Industrial De Agua Agricultura Planta Desalinizadora Precios De Mquinas ...
Water Desalination Machines RO Purification Production Plant For Drinking Bottled Filling Station Ro ...
RO Mineral Water Machine Soft Drinking Water Process Line Filtration Equipment Plant Reverse Osmosis ...
5000LPH Commercial Reverse Osmosis Water Filter System Pressure Vessel Purification Process RO ...
6000LPH Reverse Osmosis Water Filtration RO System Commercial Filter Machine Drinking Portable Water ...
Precio De Fabrica De Guangzhou Planta De Filtrado De Agua Industrial Maquinas Para Purificar Agua ...