Home Companies Shenzhen Meigaolan Electronic Instrument Co. Ltd

Rohde and Schwarz ZVA40 Network Analyzer Multipurpose Benchtop Used Test Equipment

Shenzhen Meigaolan Electronic Instrument Co. Ltd

Contact Us

[China] country

Trade Verify

Address: RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China

Contact name:Dannie

Inquir Now

Shenzhen Meigaolan Electronic Instrument Co. Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Rohde and Schwarz ZVA40 Network Analyzer Multipurpose Benchtop Used Test Equipment

Country/Region china
City & Province shenzhen
Categories Solar Chargers
InquireNow

Product Details

Rohde and Schwarz ZVA40 Network Analyzer Multipurpose Benchtop Used Test Equipment

Description of Rohde And Schwarz ZVA40

 

With its new R&S ZVA family of vector network analyzers, Rohde & Schwarz is taking a future-oriented approach.

The analyzers offer a perfect balance between measurement speed, dynamic range, flexibility and precision, making them ideal for present and future measurement tasks.

Rohde & Schwarz previously set standards in RF and microwave measurements with its R&S ZVR family of network analyzers, and now continues this success with the R&S ZVA.

The fundamental mixing concept employed by the receivers ensures high sensitivity and a wide dynamic range. Extremely fast synthesizers make for short measurement times. Its excellent characteristics, new functionality, sophisticated GUI and extremely high flexibility make the R&S ZVA an indispensable tool for demanding measurement tasks in labs and production.

  • Multiport concept
  • Highest network analyzer performance
  • Versatile functionality
  • High measurement speed
  • Modern user interface (Windows)
  • GPIB, LAN, USB
  • Pulsed profile measurement option
  • True differential Measurements option

 

List of Options

 

 

B-B18

 

Removable Flash Disk 4GB for ZVA/ZVB with control unit FMR6/5 (factory installed only)

 

B-B18

 

Removable Flash Disk 4GB for ZVA/ZVB with controller unit FMR7/3 or FMR7/6

 

B-B18

 

Removable hard disk 160GB (including firmware) for R&S® ZVA and R&S® ZVB with FMR7

 

B-B4

 

Oven quartz (OCXO) for ZVA, ZVB, ZVT

 

B-K2

 

Time domain (for ZVA, ZVB, ZVT) (software license)

 

B-K30

 

Noise figure measurement on 2 port devices (for ZVA and ZVT,

 

B16

 

Direct Generator and Receiver Access for 2 Ports

 

B18

 

Removable Flash Disc

 

B21

 

Generator Step Attenuator Port 1; mechanical, 70dB in 10dB-steps

 

B22

 

Generator Step Attenuator Port 2; mechanical, 70dB in 10dB-steps

 

B23

 

Generator Step Attenuator Port 3; mechanical, 70dB in 10dB-steps, 40 GHz

 

B24

 

Generator Step Attenuator Port 4; mechanical, 70dB in 10dB-steps, 40 GHz

 

B31

 

Receiver Step Attenuator Port 1; mechanical, 35dB in 5dB-steps

 

B32

 

Receiver Step Attenuator Port 2; mechanical, 35dB in 5dB-steps

 

B33

 

Receiver Step Attenuator Port 3; mechanical, 35dB in 5dB-steps, 40GHz

 

B34

 

Receiver Step Attenuator Port 4; mechanical, 35dB in 5dB-steps, 40GHz

 

B7

 

Measurements on pulsed signals. Pulse Profile,Recording time up to 25ms, up to 30MHz bandwidth

 

B7

 

Measurements on pulsed signals. Pulse profile,Recording time up to 25ms, up to 30MHz bandwidth

 

B8

 

External attenuator control. Control unit for electronic attenuators of ZVAZ90E, ZVA-Z110E

 

C3

 

hree years of depot calibration coverage based on the R&S recommended calibration interval - includes test data.

 

C3

 

Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data.

 

C5

 

Five years of depot calibration coverage based on the R&S recommended calibration interval - includes test data.

 

C5

 

Five years of depot calibration coverage based on the R&S recommended calibration interval - includes test data.

 

DCV-2

 

Documentation of calibration values

 

DCV-ZP

 

Printout of DCV (additional, in combination with DCV-Option only)
K10Group delay measurement on converters without LO access. For long distances via LXI network of 2 ZVA or ZVT.

 

K17

 

Increases the receiver bandwidth to 5MHz (software license)

 

K2

 

Time domain (for ZVA, ZVB, ZVT)

 

K27

 

Two internal pulse generators (for ZVA and ZVT) (software license)

 

K4

 

Mixer- and frequency converting measurements for ZVA and ZVT (software license)

 

K5

 

Vector corrected mixer measurements (for R&S®ZVA, R&S®ZVT; R&S®ZVA/T-B16 and R&S®ZVA-K4 required)

 

K6

 

True Differential Measurements for all 4-port ZVA and for ZVT with at least 3 ports

 

K7

 

Measurements on pulsed signals pulse profile, recording time up to 3ms up to 30 MHz bandwidth

 

K8

 

Control of frequency converters (for ZVA with f>20 GHz, ZVT20, includes ZVA-K4)

 

K9

 

Measurement of group delay on frequency converters without LO access (for ZVA, ZVT;

 

R3

 

Three years of depot repair coverage, including re-calibration if necessary to complete the repair.

 

R3

 

Three years of depot repair coverage, including re-calibration if necessary to complete the repair.

 

R5

 

Five years of depot repair coverage, including re-calibration if necessary to complete the repair.

 

R5

 

Five years of depot repair coverage, including re-calibration if necessary to complete the repair.

 

Our service:

 

One-stop service from manufacture to shipping.
1. Your inquiry related to our products or prices will be replied in 24hours.
2. Well-trained and experienced staffs to answer all your enquires influent English.
3. Distributor ship is offered for your unique desigh and some our current models.
4. Protection of your sales area, ideas of design and all your private information.

 

FAQ:

1. Can you ship order to Canada or Australia ?

Yes,we can .We send orders worldwide .

2. What delivery method do you use ? and delivery time ?

We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.

3. What is your payment term?

100% T/T payment before shipment.

4. How can I ask any other question ?

You can contact us online or leave us messages below.

 

 

 

 

 

Hot Products

​​Keysight Agilent N4433A 4-port RF Electronic Calibration ECal Module Description of Keysight ...
Fluke 435 Power Quality Analyzers 3-Phase, 1000 Vrms, 200 kS/s, Class A Compliant, 16 MB Memory ...
Keysight (Agilent) E4990A Impedance Analyzer, 20Hz to 10/20/30/50/120 MHZ Description The E4990A ...
Kikusui TOS9300 AC Hipot Tester with Insulation Resistance Test, 5 kV Description: The TOS9200 ...
Keysight (Agilent) 34970A Data Acquisition / Data Logger Switch Unit Description The Agilent 34970A ...
Keysight (Agilent) L4445A Microwave Switch/Attenuator Driver Description The Agilent L4445A provides ...