Home Companies Shenzhen Meigaolan Electronic Instrument Co. Ltd

Flexible 5320A Fluke Multi Function Calibrator Insulation Resistance

Shenzhen Meigaolan Electronic Instrument Co. Ltd

Contact Us

[China] country

Trade Verify

Address: RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China

Contact name:Dannie

Inquir Now

Shenzhen Meigaolan Electronic Instrument Co. Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Flexible 5320A Fluke Multi Function Calibrator Insulation Resistance

Country/Region china
City & Province shenzhen
Categories Chargers
InquireNow

Product Details

Fluke 5320A High Performance Multi-product Calibrator

Description of Fluke 5320A Multi Product Calibrator

Maximize your workload coverage with the 5320A Calibrator

The 5320A Multifunction Electrical Tester Calibrator combines many electrical calibration functions into a single instrument, replacing the resistors, decade boxes and other custom solutions commonly used to calibrate electrical testers. It’s flexible and precise enough to calibrate a wide range of instrumentation. 

Multifunction installation testers

The 5320A has all the functionality needed to calibrate installation testers with insulation resistance, continuity, loop, RCD and earth resistance test capabilities. 

Portable appliance testers (PATs)

The 5320A has all the functionality needed to calibrate PATs, with insulation resistance, ground bond, leakage current, flash voltage and load test capabilities.

Insulation resistance testers

The 5320A calibrator sources high ohms, high voltage resistors and measures the high voltage output of megohm meters and other portable and bench insulation testers. When calibrating insulation resistance testers up to 1 kV, you can select a wide range of continuously variable resistance values, from 10 kΩ to 10 GΩ, with 4 ½ digit resolution and one single value of 100 GΩ. When calibrating 5 kV insulation testers, the external 10 kV dual function adapter extends the resistors’ range up to 10 TΩ. The adapter functions both as a 1000: 1 voltage divider to 10 kV, and as a x1000 resistance multiplier to 10 TΩ.

Continuity testers and earth (ground) resistance testers

To calibrate these low ohms testers, a calibrator must be able to source precision low ohms. From its low ohms precision resistors, the 5320A calibrator sources resistance values ranging from 100 mΩ to 10 kΩ, with 3 ½ digits of resolution. Choose 2-wire or 4-wire modes for maximum flexibility.

Loop/line impedance testers and ground bond testers

The 5320A calibrator has 16 high power, high current resistors it can source, to increase the resistance of a loop or line by a known amount. Use Scan mode to automatically determine the resistance of the loop, and use Active Loop Compensation mode to compensate for any residual impedance in the loop or line.

Residual-current device (RCD) or ground fault current interrupter (GFCI) testers

The 5320A simulates a circuit breaker (an RCD/GFCI) to verify and calibrate trip current and trip time, with a wide range that enables it to accurately handle most models in this instrument category. For most RCD testers, trip times are calculated to an uncertainty of 0.25 ms, to provide better than 4:1 test uncertainty ratios (TUR). Trip current uncertainty is 1 %, which also provides better than 4:1 TURs in most applications.

Leakage current testers

Simulate a leakage current for direct/ touch, differential and substitute leakage current methods with 4 ½ digit resolution from 0.1 mA to 30 mA. The 5320A lets you choose the method that works best for your test, unlike other calibrators that only offer a single method.

Voltmeters

Many testers have built-in voltmeters. But you don’t need an additional calibrator to test this part of the workload. The model 5320A/VLC calibrator adds a precision voltage source to 600 V with 0.1 % accuracy, to calibrate V ac and V dc meters.

Hipot testers

Electrical safety testing with hipots is an integral part of development and manufacturing of electronic and electrical products, ranging from refrigerators to power supplies to test equipment to cables. Such testing is often required by government regulations to ensure product safety. The Fluke 5320A provides best-in- class hipot calibration of ac and dc voltage. The built-in 1000 V meter measures voltage and current. For voltages over 1 kV, Fluke offers two accessory items: a 10 kV adapter or 40 kV probe. With the 10 kV adapter, ac voltages to 10 kV can be calibrated with 0.5 % accuracy. Either item can be used with the built-in meter to measure voltage or flash voltage over 1000 V.

Medical safety testers

With the broad functionality and high accuracy of the 5320A, calibrating medical safety testers is a snap, allowing you to add these items to your calibration workload.

 

Technical Specifications
Precision Low Resistance Source
Ranges:100 mΩ to 10 kΩ
Resolution:3 ½ digits (continuously variable)
Maximum Current Ranges:5 mA to 400 mA
Modes:2-Wire and 4-Wire
Best 1 Year Specification:± 0.2 % of setting
High Resistance Source (High voltage)
Ranges:10 kΩ to 100 GΩ
Resolution:4 ½ digits (continuously variable to 10 GΩ)
Maximum Voltage Ranges:55 Vpk to 1575 Vpk
Best 1 Year Specification:± 0.2 % of setting
Resistance Multiplier Adapter¹ (for high resistance source)
Resistance Ranges:350 MΩ to 10 TΩ
Maximum Test Voltage:5500 V dc
Best 1 Year Specification:Uncertainty of 5320A resistor to be multiplied ± 1 % of displayed value
Low Resistance Source (High current)
Ranges:25 mΩ to 1.8 kΩ, 16 values
Maximum Current Ranges:0.025 A to 30 A (continuous)
 0.15 A to 40 A (short-term)
Best 1 Year Specification:± 5 mΩ of setting
Loop Compensation:0 to 10 Ω (Scan Mode)
 0 to 2 Ω (Active Comp Mode)
Loop Compensation Specification:± 1 % + 15 mΩ (Scan and active comp Mode)
Active Loop Compensation available on 5320A/VLC only
Line Leakage Current Source
Ranges:0.1 mA to 30 mA
Resolution:10 uA of setting
Test Voltage Ranges:10 to 250 V
Modes:Passive, Differential, Substitute, Active
Best 1 Year Specification:± 0.3% + 1 uA of setting
Residual Current Device
Trip Current Ranges:3 to 3000 mA
Trip Current Modes:0.5xI, 1xl, 1.4xI, 2xI, and 5xI
Best 1 Year Trip Current Specification:± 1 % rms
Trip Time Ranges:10 to 5000 ms
Best 1 Year Trip Time Specification:± 0.25 ms
Multimeter
Voltage Ranges:0 to 1100 V ac rms or dc
Voltage Resolution:4 ½ digits
Best 1 Year Voltage Specification:± 0.15% of reading + 5 mV
Current Ranges:0 to 30 A ac rms or dc
Current Resolution:4 ½ digits
Best 1 Year Current Specification:± 0.15% of reading + 0.15 mA
Phantom Power:0 to 33 kVA
Phantom Power Resolution:3 digits
Best 1 Year Power Specification:√((V)² + (I)²)
Hipot Leakage Current Measurement Mode (Multimeter mode)
Current Range0 to 300 mA acrms or cc
Current Resolution4 ½ digits
Best 1 Year Specification± 0.2% of reading + 0.21 mA
Hipot Timer Measurement Mode (Multimeter mode)
Timer Measurement Range0.1 to 999 s
Timer Resolution1 ms
Best 1 Year Specification0.02% + 2 ms (dc)
 0.02% + 20 ms (ac)
10 kV Divider Adapter¹ (for multimeter input)
Voltage Ranges:0 to 10 kV ac peak or dc
Voltage Divider Ratio:1000:1
Best 1 Year Specification:± 0.3 % of reading + 5 V dc
 ± 0.5 % of reading + 5 V ac (50 or 60 Hz)
40 kV Probe² (for multimeter input) Accessory
Voltage Ranges:0 to 40 kV ac peak or dc
Voltage Divider Ratio:1000:1
Best 1 Year Specification:± 0.5 % of reading + 10 V dc
 ± 0.5 % of reading + 10 V ac (50 or 60 Hz)
Voltage Calibrator Source (5320A/VLC only)
Ranges:3 to 600 V ac or dc
Voltage Resolution:4 digits
Frequency:40 to 400 Hz
Frequency Resolution:3 digits
Maximum Burden Current:500 mA (ac)
 5 mA (dc)
Best 1 Year Current Specification:± 0.1 % of setting + 9 mV
General Specifications
Warm up Time
 30 minutes
Temperature Performance
Operating:18 ºC to 28 ºC
Calibration Temperature (Tcal):23º C
Storage:- 20 ºC to + 70 ºC
Altitude
Operating:3,050 m (10,00 ft)
Storage:12,200 m (40,000 ft)
Calibration Documentation17025 accredited report of calibration included
Dimensions
 450 mm X 480 mm X 170 mm (17.7 in. X 18.9 in. X 6.7 in.)
Weight
 18 kg (39.7 lbs.)
Power Line
 115/230 V ac ± 10 % (50/60 Hz)
Power Consumption
 150 VA Maximum
Safety
 Class I, according to EN 61010-1
 
List of Options

 

Model NameDescription
5320AMultifunction Electrical Tester Calibrator
5320A/40Multifunction Electrical Tester Calibrator with 40 kV Probe
5320A/VLCMultifunction Electrical Tester Calibrator with 600 V Source and Active Loop Compensator
5320A/VLC/405320A/VLC Multifunction Electrical Tester Calibrator with 40 kV Probe


FAQ:

1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .

 

Hot Products

​​Keysight Agilent N4433A 4-port RF Electronic Calibration ECal Module Description of Keysight ...
Fluke 435 Power Quality Analyzers 3-Phase, 1000 Vrms, 200 kS/s, Class A Compliant, 16 MB Memory ...
Keysight (Agilent) E4990A Impedance Analyzer, 20Hz to 10/20/30/50/120 MHZ Description The E4990A ...
Kikusui TOS9300 AC Hipot Tester with Insulation Resistance Test, 5 kV Description: The TOS9200 ...
Keysight (Agilent) 34970A Data Acquisition / Data Logger Switch Unit Description The Agilent 34970A ...
Keysight (Agilent) L4445A Microwave Switch/Attenuator Driver Description The Agilent L4445A provides ...