Product Details

Rohde And Schwarz ZVA24 Vector Network Analyzer 300 KHz Up To 24 GHz

 

Description of Rohde And Schwarz ZVA24

 

With its new R&S ZVA family of vector network analyzers, Rohde & Schwarz is taking a future-oriented approach. The analyzers offer a perfect balance between measurement speed, dynamic range, flexibility and precision, making them ideal for present and future measurement tasks.

Rohde & Schwarz previously set standards in RF and microwave measurements with its R&S ZVR family of network analyzers, and now continues this success with the R&S ZVA. The fundamental mixing concept employed by the receivers ensures high sensitivity and a wide dynamic range. Extremely fast synthesizers make for short measurement times. Its excellent characteristics, new functionality, sophisticated GUI and extremely high flexibility make the R&S ZVA an indispensable tool for demanding measurement tasks in labs and production.

Overview and Features of ZVA24 Vector Network Analyzer

  • Multiport concept
  • Highest network analyzer performance
  • Versatile functionality
  • High measurement speed
  • Modern user interface (Windows)
  • GPIB, LAN, USB
  • Pulsed profile measurement option
  • True differential Measurements option

List of Options

B-B18Removable Flash Disk 4GB for ZVA/ZVB with control unit FMR6/5 (factory installed only)
B-B18Removable Flash Disk 4GB for ZVA/ZVB with controller unit FMR7/3 or FMR7/6
B-B18Removable hard disk 160GB (including firmware) for R&S® ZVA and R&S® ZVB with FMR7
B-B4Oven quartz (OCXO) for ZVA, ZVB, ZVT
B-K2Time domain (for ZVA, ZVB, ZVT) (software license)
B-K30Noise figure measurement on 2 port devices (for ZVA and ZVT,
B16Direct generator/receiver access for 2-port ZVA24
B16Direct generator/receiver access for 4-port ZVA24
B21Generator attenuator port 1, mechanical, 70 dB in 10-dB-steps, 24 GHz
B22Generator attenuator port 2 mechanical, 70 dB in 10-dB-steps 24 GHz
B23Generator attenuator port 3 mechanical, 70 dB in 10-dB-steps, 24 GHz
B24Generator attenuator port 4 mechanical, 70 dB in 10-dB-steps 24 GHz
B31Receiver attenuator port 1 mechanical, 35 dB in 5-dB-steps 24 GHz
B32Receiver attenuator port 2 mechanical, 35 dB in 5-dB-steps, 24 GHz
B33Receiver attenuator port 3, mechanical, 35 dB in 5-dB-steps, 24 GHz
B34Receiver attenuator port 4 mechanical, 35 dB in 5-dB-steps, 24 GHz
B7Measurements on pulsed signals. Pulse Profile,Recording time up to 25ms, up to 30MHz bandwidth
B7Measurements on pulsed signals. Pulse profile,Recording time up to 25ms, up to 30MHz bandwidth
B8External attenuator control. Control unit for electronic attenuators of ZVAZ90E, ZVA-Z110E
C3THREE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY
C3THREE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY
C5FIVE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY
C5FIVE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY
DCV-2Documentation of calibration values
DCV-ZPPrintout of DCV (additional, in combination with DCV-Option only)
DKDZVA24 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device)
K10Group delay measurement on converters without LO access. For long distances via LXI network of 2 ZVA or ZVT.
K17Increases the receiver bandwidth to 5MHz (software license)
K27Two internal pulse generators (for ZVA and ZVT) (software license)
K4Mixer- and frequency converting measurements for ZVA and ZVT (software license)
K5Vector corrected mixer measurements (for R&S®ZVA, R&S®ZVT; R&S®ZVA/T-B16 and R&S®ZVA-K4 required)
K6True Differential Measurements for all 4-port ZVA and for ZVT with at least 3 ports
K7Measurements on pulsed signals pulse profile, recording time up to 3ms up to 30 MHz bandwidth
K8Control of frequency converters (for ZVA with f>20 GHz, ZVT20, includes ZVA-K4)
K9Measurement of group delay on frequency converters without LO access (for ZVA, ZVT;
R3THREE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12
R3THREE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12
R5FIVE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12
R5FIVE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12

FAQ:

1. Can you ship order to Canada or Australia ?

Yes,we can .We send orders worldwide .

2. What delivery method do you use ? and delivery time ?

We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.

3. What is your payment term?

100% T/T payment before shipment.

4. How can I ask any other question ?

You can contact us online or leave us messages below.

 

 

 

 

Hot Products

​​Keysight Agilent N4433A 4-port RF Electronic Calibration ECal Module Description of Keysight ...
Fluke 435 Power Quality Analyzers 3-Phase, 1000 Vrms, 200 kS/s, Class A Compliant, 16 MB Memory ...
Keysight (Agilent) E4990A Impedance Analyzer, 20Hz to 10/20/30/50/120 MHZ Description The E4990A ...
Kikusui TOS9300 AC Hipot Tester with Insulation Resistance Test, 5 kV Description: The TOS9200 ...
Keysight (Agilent) 34970A Data Acquisition / Data Logger Switch Unit Description The Agilent 34970A ...