Light Weight Ups Battery Pack , Lifepo4 Ev Battery Pack 12Ah / 20Ah / 25Ah / 27Ah

 

1. Lithium battery module feature

  • High energy density
  • High working voltage for single battery cells
  • Pollution-free
  • Long cycle life
  • No memory effect
  • Capacity, resistance, Voltage, platform time consistency is good
  • With short-circuit production function, safe and reliable
  • Factory price & High quality
  • Good consistency, low self discharge
  • Light weight, small size
  • High discharge rate
  • Quality and security guaranted,with CE,ROHS approval.
  • The lifepo4 battery pack is widely used for electric bicycle,golf car,electric bike,electric wheelchair,power tools,electric scooter,emergency light,etc

 

2. Lithium battery module can be assembled with various cells,

    available to make all customzied battery pack. Cell's details as below:

3.2V Lithium Iron Phosphate Cells
Cell ModelVolt(V)Capacity(Ah)Inpendance(mΩ)Weight(g)Cycle lifeCycle condition
TB-01865135C-12Ah3.2V12Ah≤12310±102000 cycles100% DOD
TB-02707145C-20Ah3.2V20Ah≤10525±102000 cycles100% DOD
TB-02707145D-20Ah3.2V20Ah≤4525±102000 cycles100% DOD
TB-02707180C-25Ah3.2V25Ah≤6650±102000 cycles100% DOD
TB-02707180D-25Ah3.2V25Ah≤4650±102000 cycles100% DOD
TB-02707180C-27Ah3.2V27Ah≤4660±102000 cycles100% DOD

 

3. Safety test of battery cell

No.ItemTest MethodCriteria
6.1Short- circuit TestA cell is tested in accordance with 3.2, after that the cell is short-circuited by connecting the positive and negative terminals with a wire for 10min, the wire has a maximum resistance load of 5mΩ., then observe for 1h.No fire, no explosion
6.2

Overcharge

Test

 

A cell is tested in accordance with 3.2, then 1C constant current charged till the voltage reaches 1.5 times of the specified end-off charge voltage, or the charge time reaches 1h, then stop charge, and observe for 1h.

 

No fire, no explosion

 

6.3Over discharge test

A cell is tested in accordance with 3.2, then 1C discharge for 90min, then observe for 1h.

 

 

No fire, no explosion, no leakage

 

6.4

Crush Test

 

A cell is tested in accordance with 3.2, and then is placed on the crush machine, the axis is parallel to the crush equiment, and it is crushed between two flat surfaces till the crushing force is gradually approaching 200 kN, or voltage reaches 0V,or reaches 30% distortion, then observe for 1h.

 

No fire, no explosion

 

6.5

Impact Test

 

A cell is tested in accordance with 3.2, and then placed on the impact flat. A Φ15.8mm bar is to be placed on the center of the cell. A 9.1kg weight is dropped from a height of 610mm onto the cell, the distortion is allowed.

 

No fire, no explosion

 

6.6Stick Test

a) A cell is tested in accordance with 3.2

b) use φ5mm~φ8mm high temperature resistance steel needle, with speed of 25±5mm/s, to go through the cell from vertical direction of pole plate, the penetrate position should be close to the geometric center of plate surface, the steel needle remains in the cell;

 

 

No fire, no explosion

 

6.7

Heating

Test(130℃)

 

A cell is tested in accordance with 3.2, and then heated in a circulating air oven. The temperature of the oven is raised at a rate of 5℃ per minute to 130℃±3℃ and remain for 30 min.

 

 

No fire, no explosion

 

 

4. Our Service

  • Fast Delivery, can handle shipping for customer if needed
  • Samples are available with charged
  • 2 years warranty
  • Every battery pack can be customized according to your specific demand. OEM is acceptable.
  • Expertist technical support and good after-sales service

5. Battery operation instruction

  • Charging current: Do not surpass the largest charging current that specification stipulated.
  • Charging voltage: Do not surpass the highest limited voltage that specification stipulated.
  • Charging temperature: within temperature scope that specification stipulated.
  • Charge with constant current, then with the constant voltage, no reverse charge, which is dangerous
  • Special note: Short time doesn't affect the use of the battery overcharge too, but for a long period of time over discharge or over charge can affect the function of the battery failure, or the battery can't use permanent, appear serious safety hazards, need long time floating please use the recommended floating model specification.Battery when not in use for a long time, because of its own self-discharge characteristics can also cause discharge, to prevent the occurrence of a discharge, battery should maintain a certain capacity, maintain the voltage at 50% state of SOC.

6. Lithium battery module solution

 

 

Hot Products

12V 75ah Rechargeable Lifepo4 Battery , Black LiFePO4 Power Battery CE Certificated 1. General ...
Environment - Friendly LiFePO4 Battery Cells Low Self - Discharge Lithium Iron Phosphate · long life ...
3.2V 20Ah Rechargeable LiFePO4 Battery Pack High Rate UL UN38.3 IEC62619 Approval 1,General This ...
3.2V 50Ah Rechargeable LiFePO4 Battery 2 Years Warranty and Low Self - Discharge 1. General This ...
Prismatic Lifepo4 Battery Cells Low Self - Discharge 3.2V 12Ah 20Ah 25Ah 50Ah · long life & deep ...
Low Self-discharge 3.2V50Ah Rechargeable Lifepo4 Battery with 2 Years Warranty and TUV/ UN38.3 1. ...